Table Of Contents
Preparing to Install the Router
Safety Recommendations
Safety with Electricity
Preventing Electrostatic Discharge Damage
General Site Requirements
Power Supply Considerations
Site Environment
Site Configuration
Equipment Racks
Installation Checklist
Creating a Site Log
Inspecting the Router
Tools and Equipment for Installation and Maintenance
Console and Auxiliary Port Considerations
Console Port Connections
Auxiliary Port Connections
Preparing to Connect to a Network
Ethernet Connections
Token Ring Connections
Serial Connections
Configuring Serial Connections
Serial DTE or DCE Devices
Signaling Standards Supported
Distance Limitations
Asynchronous/Synchronous Serial Module Baud Rates
ISDN BRI Connections
56-K/Switched-56-kbps DSU/CSU Connections
Preparing to Install the Router
This chapter describes important information to consider before you begin to install a Cisco 2600 series router, and includes the following sections:
•
Safety Recommendations
•
General Site Requirements
•
Installation Checklist
•
Creating a Site Log
•
Inspecting the Router
•
Tools and Equipment for Installation and Maintenance
•
Console and Auxiliary Port Considerations
•
Preparing to Connect to a Network
After you have completed this chapter, proceed to Chapter 3, "Installing the Router" for installation instructions.
Safety Recommendations
Follow these guidelines to ensure general safety:
•
Keep the chassis area clear and dust-free during and after installation.
•
If you remove the chassis cover, put it in a safe place.
•
Keep tools and chassis components away from walk areas.
•
Do not wear loose clothing that could get caught in the chassis. Fasten your tie or scarf and roll up your sleeves.
•
Wear safety glasses when working under conditions that might be hazardous to your eyes.
•
Do not perform any action that creates a hazard to people or makes the equipment unsafe.
Safety with Electricity
Follow these guidelines when working on equipment powered by electricity:
Warning
Read the installation instructions before connecting the system to the power source. Statement 1004
•
Locate the emergency power-off switch in the room in which you are working. Then, if an electrical accident occurs, you can quickly turn off the power.
•
Disconnect all power before doing the following:
–
Installing or removing a chassis
–
Working near power supplies
•
Look carefully for possible hazards in your work area, such as moist floors, ungrounded power extension cables, frayed power cords, and missing safety grounds.
•
Do not work alone if hazardous conditions exist.
•
Never assume that power is disconnected from a circuit. Always check.
•
If an electrical accident occurs, proceed as follows:
–
Use caution; do not become a victim yourself.
–
Turn off power to the device.
–
If possible, send another person to get medical aid. Otherwise, assess the victim's condition and then call for help.
–
Determine if the person needs rescue breathing or external cardiac compressions; then take appropriate action.
In addition, use the following guidelines when working with any equipment that is disconnected from a power source, but still connected to telephone wiring or other network cabling:
•
Never install telephone wiring during a lightning storm.
•
Never install telephone jacks in wet locations unless the jack is specifically designed for it.
•
Never touch uninsulated telephone wires or terminals unless the telephone line is disconnected at the network interface.
•
Use caution when installing or modifying telephone lines.
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It can occur if electronic printed circuit cards are improperly handled and can cause complete or intermittent failures. Always follow ESD prevention procedures when removing and replacing modules:
•
Ensure that the router chassis is electrically connected to earth ground.
•
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to channel unwanted ESD voltages safely to ground. To guard against ESD damage and shocks, the wrist strap and cord must operate effectively.
•
If no wrist strap is available, ground yourself by touching a metal part of the chassis.
Caution 
For the safety of your equipment, periodically check the resistance value of the antistatic strap. It should be between 1 and 10 megohms (Mohm).
General Site Requirements
This section describes the requirements your site must meet for safe installation and operation of your router. Ensure that the site is properly prepared before beginning installation. If you are experiencing shutdowns or unusually high errors with your existing equipment, this section can also help you isolate the cause of failures and prevent future problems.
Power Supply Considerations
Check the power at your site to ensure that you are receiving "clean" power (free of spikes and noise). Install a power conditioner if necessary.
Warning
The device is designed for connection to TN and IT power systems. Statement 1007
The AC power supply includes the following features:
•
Autoselects either 110-V or 220-V operation.
•
All units include a 6-foot (1.8-meter) electrical power cord. (A label near the power cord indicates the correct voltage, frequency, current draw, and power dissipation for the unit.)
Table 2-1 describes power requirements for Cisco 2600 series routers.
Table 2-1 Power Requirements for Cisco 2600 Series Routers
Power Source
|
Input Power
|
Input Voltage Tolerance Limits
|
AC
|
100 - 240 VAC, 1.0 A, 50 - 60 Hz
|
85 - 264 VAC
|
DC
|
48 - 60 VDC, 3.0 A
|
38 - 72 VDC
|
Site Environment
The router can be placed on a desktop or mounted in a rack. Single rack-unit (1RU) routers can also be mounted on a wall. The location of the chassis and the layout of your equipment rack or wiring room are extremely important for proper system operation. Placing equipment too close together, inadequate ventilation, and inaccessible panels can make system maintenance difficult or cause system malfunctions and shutdowns.
When planning your site layout and equipment locations, remember the precautions described in the next section, "Site Configuration," to help avoid equipment failures and reduce the possibility of environmentally caused shutdowns. If you are currently experiencing shutdowns or unusually high errors with your existing equipment, these precautions may help you isolate the cause of the failures and prevent future problems.
Site Configuration
The following precautions will help you plan an acceptable operating environment for your router and help you avoid environmentally caused equipment failures:
•
Ensure that the room in which you operate your system has adequate air circulation. Electrical equipment generates heat. Ambient air temperature might not be able to cool equipment to acceptable operating temperatures without adequate circulation.
•
Always follow the ESD-prevention procedures described in the "Preventing Electrostatic Discharge Damage" section to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent equipment failure.
•
Ensure that the chassis cover is secure. The chassis is designed to allow cooling air to flow effectively inside it. An open chassis allows air leaks, which might interrupt and redirect the flow of cooling air from internal components.
Equipment Racks
Cisco 2600 series routers with chassis height of 1 RU can be installed in 19-, 23-, and 24-inch racks.
Cisco 2600 series routers with chassis height of 2 RU can be installed in 19- or 23-inch racks.
The following information will help you plan your equipment rack configuration:
•
Enclosed racks must have adequate ventilation. Ensure that the rack is not overly congested, because each unit generates heat. An enclosed rack should have louvered sides and a fan to provide cooling air.
•
When mounting a chassis in an open rack, ensure that the rack frame does not block the intake ports or the exhaust ports. If the chassis is installed on slides, check the position of the chassis when it is seated all the way into the rack.
•
In an enclosed rack with a ventilation fan in the top, excessive heat generated by equipment near the bottom of the rack can be drawn upward and into the intake ports of the equipment above it in the rack. Ensure that you provide adequate ventilation for equipment at the bottom of the rack.
•
Baffles can help to isolate exhaust air from intake air, which also helps to draw cooling air through the chassis. The best placement of the baffles depends on the airflow patterns in the rack, which can be found by experimenting with different arrangements.
Installation Checklist
The sample Installation Checklist lists items and procedures for installing a new router. Make a copy of this checklist and mark the entries when completed. Include a copy of the checklist for each router in your Site Log (described in the next section, "Creating a Site Log").
Installation checklist for site _____________________________________________
Router name _______________________________________________________
|
Task
|
Verified by
|
Date
|
Installation Checklist copied
|
|
|
Background information placed in Site Log
|
|
|
Site power voltages verified
|
|
|
Installation site power check completed
|
|
|
Required tools available
|
|
|
Additional equipment available
|
|
|
Router received
|
|
|
The appropriate quick start guide for your router received
|
|
|
Cisco 2600 Series, Cisco 3600 Series, and Cisco 3700 Series Regulatory Compliance and Safety Information document received
|
|
|
Product registration card received
|
|
|
Cisco.com contact information label received
|
|
|
Chassis components verified
|
|
|
Initial electrical connections established
|
|
|
ASCII terminal (for local configuration) or modem (for remote configuration)
|
|
|
Signal distance limits verified
|
|
|
Startup sequence steps completed
|
|
|
Initial operation verified
|
|
|
Software image verified
|
|
|
Creating a Site Log
The Site Log provides a record of all actions related to the router. Keep it in an accessible place near the chassis where anyone who performs tasks has access to it. Use the Installation Checklist to verify steps in the installation and maintenance of the router. Site Log entries might include the following:
•
Installation progress—Make a copy of the Installation Checklist and insert it into the Site Log. Make entries as each procedure is completed.
•
Upgrade and maintenance procedures—Use the Site Log as a record of ongoing router maintenance and expansion history. A Site Log might include the following events:
–
Installation of network modules
–
Removal or replacement of network modules and other upgrades
–
Configuration changes
–
Maintenance schedules and requirements
–
Maintenance procedures performed
–
Intermittent problems
–
Comments and notes
Inspecting the Router
Do not unpack the router until you are ready to install it. If the final installation site will not be ready for some time, keep the chassis in its shipping container to prevent accidental damage. When you are ready to install the router, proceed with unpacking it.
The router, cables, publications, and any optional equipment you ordered may be shipped in more than one container. When you unpack the containers, check the packing list to ensure that you received all the following items:
•
Router
•
6-foot (1.8-meter) power cord
•
Rubber feet for desktop mounting (with routers of 1 rack-unit height only)
•
Rack-mount brackets with screws for 19-inch rack (with all Cisco 2600 series routers)
•
Rack-mount brackets with screws for 23-inch rack (with Cisco 2691 routers only)
•
Grounding lug and bracket
•
RJ-45-to-DB-9 adapter cable for console connection
•
RJ-45-to-DB-25 adapter cable for modem connection
•
Ethernet cable
•
Optional equipment (such as network connection cables or additional rack-mount brackets)
•
Cisco 2600 Series Modular Routers Quick Start Guide
•
Cisco 2600 Series, Cisco 3600 Series, and Cisco 3700 Series Regulatory Compliance and Safety Information document
Inspect all items for shipping damage. If anything appears to be damaged, or if you encounter problems installing or configuring your router, contact customer service. Warranty, service, and support information is in the quick start guide that shipped with your router.
Tools and Equipment for Installation and Maintenance
You need the following tools and equipment to install and upgrade the router and its components:
•
ESD-preventive cord and wrist strap
•
Number 2 Phillips screwdriver
•
Flat-blade screwdrivers: small, 3/16-inch (4-5 mm) and medium, 1/4-inch (5-6 mm)
–
To install or remove modules
–
To remove the cover or mainboard tray, if you are upgrading memory or other components
•
Rack-mount screws
•
ROM 32-pin PLCC extractor tool
•
Needlenose pliers
–
For straightening any pins bent when you install the ROM
•
Cable ties, if required, for organizing cables
To install a Cisco 2600 router of 1 rack-unit height on a wall, you need suitable screws or wall anchors.
In addition, depending on the type of modules you plan to use, you might need the following equipment to connect a port to an external network:
•
Cables for connection to the WAN and LAN ports (dependent on configuration).
Note
For more information on cable specifications, refer to the Cisco Modular Access Router Cable Specifications document online or on the Documentation CD-ROM.
•
Ethernet hub or PC with a network interface card for connection to Ethernet (LAN) ports.
•
Console terminal (an ASCII terminal or a PC running terminal emulation software) configured for 9600 baud, 8 data bits, no parity, and 1 stop bit.
•
Modem for connection to the auxiliary port for remote administrative access (optional).
•
Token Ring interfaces require a Token Ring media attachment unit (MAU).
•
Serial interfaces may require a data service unit (DSU) or channel service unit/data service unit (DSU/CSU).
•
CT1/PRI modules without the built-in CSU require an external CSU.
•
ISDN BRI S/T interfaces require an NT1 device if one is not supplied by your service provider.
Console and Auxiliary Port Considerations
The router includes an asynchronous serial console port and an auxiliary port. The console and auxiliary ports provide access to the router either locally using a console terminal, or remotely using a modem connected to the auxiliary port. This section discusses important cabling information to consider before connecting a console terminal, which can be either an ASCII terminal or a PC running terminal emulation software, to the console port or modem to the auxiliary port.
The main difference between the console and auxiliary ports is that the auxiliary port supports hardware flow control and the console port does not. Flow control paces the transmission of data between a sending device and a receiving device. Flow control ensures that the receiving device can absorb the data sent to it before the sending device sends more. When the buffers on the receiving device are full, a message is sent to the sending device to suspend transmission until the data in the buffers has been processed. Because the auxiliary port supports flow control, it is ideally suited for use with the high-speed transmissions of a modem. Console terminals transmit at slower speeds than modems; therefore, the console port is ideally suited for use with console terminals.
Console Port Connections
The router has an EIA/TIA-232 asynchronous serial console port (RJ-45). Depending on the cable and the adapter used, this port appears as a DTE or DCE device at the end of the cable.
For connection to a PC running terminal emulation software, your router is provided with an RJ-45 to DB-9 adapter cable.
To connect the router to an ASCII terminal, use an RJ-45 rollover cable and an RJ-45-to-DB-25 female adapter (not provided).
The default parameters for the console port are 9600 baud, 8 data bits, no parity, and 1 stop bit. The console port does not support hardware flow control. For detailed information about installing a console terminal, refer to the "Connecting to a Console Terminal or Modem" section on page 3-20.
For cable and port pinouts, refer to the Cisco Modular Access Router Cable Specifications document online or on the Documentation CD-ROM.
Auxiliary Port Connections
The router has an EIA/TIA-232 asynchronous serial auxiliary port (RJ-45) that supports flow control. Depending on the cable and the adapter used, this port appears as a DTE or DCE device at the end of the cable.
For connection to a modem, your router is provided with an RJ-45-to-DB-25 adapter cable.
For detailed information about connecting devices to the auxiliary port, refer to the "Connecting to a Console Terminal or Modem" section on page 3-20.
For cable and port pinouts, refer to the Cisco Modular Access Router Cable Specifications document online or on the Documentation CD-ROM.
Preparing to Connect to a Network
When setting up your router, consider distance limitations and potential electromagnetic interference (EMI) as defined by the applicable local and international regulations.
Network connection considerations are provided for several types of network interfaces and are described in the following sections:
•
Ethernet Connections
•
Token Ring Connections
•
Serial Connections
•
ISDN BRI Connections
•
56-K/Switched-56-kbps DSU/CSU Connections
Refer to the following online documents for more information about network connections and interfaces:
•
Cisco Network Modules Hardware Installation Guide
•
Cisco Interface Cards Installation Guide
•
Cisco Modular Access Router Cable Specifications
Warning
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Statement 1021
Ethernet Connections
The IEEE has established Ethernet as standard IEEE 802.3. The most common Ethernet implementations are as follows:
•
100BASE-T—2-pair Category 5 or unshielded twisted-pair (UTP) straight-through RJ-45 cable.
•
10BASE-2—Ethernet on thin coaxial cable, also known as thin Ethernet. The maximum segment distance is 607 feet (186 meters).
•
10BASE-5—Ethernet on thick coaxial cable, also known as thick Ethernet. The maximum segment distance is 1,640 feet (500 meters).
•
10BASE-T—Ethernet on unshielded twisted-pair (UTP) cable. The maximum segment distance is 328 feet (100 meters). UTP cables look like the wiring used for ordinary telephones; however, UTP cables meet certain electrical standards that telephone cables do not meet.
Table 2-2 lists the router models described in this guide and summarizes the LAN interfaces supported on each model.
Table 2-2 Cisco 2600 Series LAN Connections
Model
|
Ethernet (10BASE-T)
|
Token Ring (RJ-45)
|
Fast Ethernet (10/100)
|
Network Module Slot
|
WAN Interface Card Slots
|
Advanced Integration Module Slots
|
Cisco 2610
|
1
|
—
|
—
|
1
|
2
|
1
|
Cisco 2610XM
|
—
|
—
|
1
|
1
|
2
|
1
|
Cisco 2611
|
2
|
—
|
—
|
1
|
2
|
1
|
Cisco 2611XM
|
—
|
—
|
2
|
1
|
2
|
1
|
Cisco 2612
|
1
|
1
|
—
|
1
|
2
|
1
|
Cisco 2613
|
—
|
1
|
—
|
1
|
2
|
1
|
Cisco 2620
|
—
|
—
|
1
|
1
|
2
|
1
|
Cisco 2620XM
|
—
|
—
|
1
|
1
|
2
|
1
|
Cisco 2621
|
—
|
—
|
2
|
1
|
2
|
1
|
Cisco 2621XM
|
—
|
—
|
2
|
1
|
2
|
1
|
Cisco 2650
|
—
|
—
|
1
|
1
|
2
|
1
|
Cisco 2650XM
|
—
|
—
|
1
|
1
|
2
|
1
|
Cisco 2651
|
—
|
—
|
2
|
1
|
2
|
1
|
Cisco 2651XM
|
—
|
—
|
2
|
1
|
2
|
1
|
Cisco 2691
|
—
|
—
|
2
|
1
|
3
|
2
|
Token Ring Connections
The Cisco 2612 router provides both an Ethernet interface and a Token Ring shielded UTP interface. The Cisco 2613 router provides a single Token Ring interface. (See Table 2-2.)
The IEEE has established Token Ring as standard IEEE 802.5. Specifications indicate a maximum segment distance of 328 feet (100 meters) for UTP cabling.
Note
To ensure agency compliance with FCC Class B electromagnetic emissions requirements (EMI), make sure that you use a shielded RJ-45 Token Ring cable when connecting your router to a Token Ring network.
Token Ring can operate at two different ring speeds: 4 and 16 Mbps. All devices on the Token Ring must use the same operating speed.
Use a Token Ring cable to connect the router to a switch. Refer to the section "Token Ring Port Pinouts" in the Cisco Modular Access Router Cable Specifications online document for the Token Ring port pinouts. This document is available online and on the Cisco Documentation CD-ROM.
Serial Connections
Serial connections are provided by WAN interface cards and network modules. The WAN interface cards can be installed in either slot of the 2-slot chassis; the network module can be installed in the Cisco 2600 series single network module slot. For more information on WAN interface cards, refer to the Cisco Interface Cards Hardware Installation Guide. For more information on network modules, refer to the Cisco Network Modules Hardware Installation Guide. These documents are accessible online and on the Cisco Documentation CD-ROM.
•
For information about installing WAN interface cards, refer to the Cisco Interface Cards Hardware Installation Guide.
•
For information about installing network modules, refer to the Cisco Network Modules Hardware Installation Guide.
Before you connect a device to a serial port, you need to know the following:
•
Type of device, data terminal equipment (DTE) or data communications equipment (DCE), you are connecting to the synchronous serial interface
•
Type of connector, male or female, required to connect to the device
•
Signaling standard required by the device
Configuring Serial Connections
The serial ports on the asynchronous/synchronous serial network modules and the serial WAN interface card use DB-60 connectors. Serial ports can be configured as DTE or DCE, depending on the serial cable used.
Serial DTE or DCE Devices
A device that communicates over a synchronous serial interface is either a DTE or DCE device. A DCE device provides a clock signal that paces the communications between the device and the router. A DTE device does not provide a clock signal. DTE devices usually connect to DCE devices. The documentation that accompanied the device should indicate whether it is a DTE or DCE device. (Some devices have a jumper to select either DTE or DCE mode.) If you cannot determine the device type in the documentation, see Table 2-3 to help you select the proper device type.
Table 2-3 Typical DTE and DCE Devices
Device Type
|
Gender
|
Typical Devices
|
DTE
|
Male1
|
Terminal
PC
|
DCE
|
Female2
|
Modem
DSU/CSU
Multiplexer
|
Signaling Standards Supported
The synchronous serial ports available for the router support the following signaling standards: EIA/TIA-232, EIA/TIA-449, V.35, X.21, and EIA-530. You can order a Cisco DB-60 shielded serial transition cable that has the appropriate connector for the standard you specify. The documentation for the device you want to connect should indicate the standard used for that device. The router end of the shielded serial transition cable has a DB-60 connector, which connects to the DB-60 port on a serial WAN interface card. The other end of the serial transition cable is available with a connector appropriate for the standard you specify.
The synchronous serial port can be configured as DTE or DCE, depending on the attached cable (except EIA-530, which is DTE only). To order a shielded cable, contact customer service. See the "Obtaining Documentation" section on page xvii.
Note
All serial ports configured as DTE require external clocking from a DSU/CSU or other DCE device.
Although manufacturing your own serial cables is not recommended (because of the small size of the pins on the DB-60 serial connector), cable pinouts are provided in the Cisco Modular Access Router Cable Specifications.
Distance Limitations
Serial signals can travel a limited distance at any given bit rate; generally, the slower the data rate, the greater the distance. All serial signals are subject to distance limits, beyond which a signal significantly degrades or is completely lost.
Note
Only the serial WAN interface card supports bit rates above 128 Kbps.
Table 2-4 lists the recommended maximum speeds and distances for each serial interface type; however, you might get good results at speeds and distances greater than those listed, if you understand the electrical problems that might arise and can compensate for them. For instance, the recommended maximum rate for V.35 is 2 Mbps, but 4 Mbps is commonly used.
Table 2-4 Serial Signal Transmission Speeds and Distances
|
EIA/TIA-232 Distance
|
EIA/TIA-449, X.21, V.35, EIA-530 Distance
|
Rate (bps)
|
Feet
|
Meters
|
Feet
|
Meters
|
2400
|
200
|
60
|
4100
|
1250
|
4800
|
100
|
30
|
2050
|
625
|
9600
|
50
|
15
|
1025
|
312
|
19200
|
25
|
7.6
|
513
|
156
|
38400
|
12
|
3.7
|
256
|
78
|
56000
|
8.6
|
2.6
|
102
|
31
|
1544000 (T1)
|
—
|
—
|
50
|
15
|
Balanced drivers allow EIA/TIA-449 signals to travel greater distances than EIA/TIA-232 signals. The recommended distance limits for EIA/TIA-449 shown in Table 2-4 are also valid for V.35, X.21, and EIA-530. Typically, EIA/TIA-449 and EIA-530 can support 2-Mbps rates, and V.35 can support 4-Mbps rates.
Asynchronous/Synchronous Serial Module Baud Rates
The following baud-rate limitations apply to the slow-speed serial interfaces found in the asynchronous/synchronous serial modules:
•
Asynchronous interface—Maximum baud rate is 115.2 kbps.
•
Synchronous interface—Maximum baud rate is 128-kbps full duplex.
ISDN BRI Connections
The BRI WAN interface cards provide Integrated Services Digital Network (ISDN) Basic Rate Interface (BRI) connections. The BRI modules and BRI WAN interface cards are available with either an S/T interface that requires an external Network Terminator 1 (NT1), or a U interface that has a built-in NT1.
You can install the BRI modules in any available slot in the chassis.
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables, detach the end away from the unit first. Statement 1026
Use a BRI cable (not included) to connect the BRI WAN interface card directly to an ISDN. Table 2-5 lists the specifications for ISDN BRI cables. Also, refer to the Cisco Modular Access Router Cable Specifications online document for pinouts. This document is located on Cisco.com and the Documentation CD-ROM.
Table 2-5 ISDN-BRI Cable Specifications
Specification
|
High-Capacitance Cable
|
Low-Capacitance Cable
|
Resistance (at 96 kHz)
|
160 ohms/km
|
160 ohms/km
|
Capacitance (at 1 kHz)
|
120 nF1 /km
|
30 nF/km
|
Impedance (at 96 kHz)
|
75 ohms
|
150 ohms
|
Wire diameter
|
0.024 in. (0.6 mm)
|
0.024 in. (0.6 mm)
|
Distance limitation
|
32.8 ft (10 m)
|
32.8 ft (10 m)
|
For more information on BRI WAN interface cards, refer to the Cisco Interface Cards Installation Guide online document. This document is located on Cisco.com and the Documentation CD-ROM.
56-K/Switched-56-kbps DSU/CSU Connections
Switched-56-kbps connections are provided by the 56-kbps DSU/CSU WAN interface card.
For more information on Switched-56-kbps WAN interface cards, refer to the Cisco Interface Cards Installation Guide online document. This document is located on Cisco.com and the Documentation CD-ROM.