Table 28-1 Conditions
Condition
|
Description
|
AIS
|
Alarm Indication Signal
|
AIS-L
|
Alarm Indication Signal—Line
|
ALS
|
Automatic Laser Shutdown
|
AMPLI-INIT
|
Optical Amplifier Initialization
|
APC-DISABLED
|
Automatic Power Control Disabled
|
APC-FAIL
|
Automatic Power Control Failure
|
APSB
|
Byte Failure
|
APSC-IMP
|
Improper Automatic Protection Switch (APS) Code
|
APSCDFLTK
|
Default K Byte
|
APSCINCON
|
Inconsistent APS Code
|
APSCM
|
Protection Switching Channel Match Failure
|
APSCNMIS
|
Node ID Mismatch
|
APSIMP
|
APS Invalid Mode
|
APSMM
|
APS Mode Mismatch
|
AS-CMD
|
Alarms Suppressed By User Command
|
AS-MT
|
Alarms Suppressed For Maintenance
|
AU-AIS
|
AIS—Administration Unit—Alarm Indication Signal
|
AU-LOF
|
LOF—Administration Unit—Loss of Multi Frame
|
AU-LOP
|
LOP—Administration Unit—Loss of Pointer
|
AUD-LOG-LOSS
|
Audit Log 100 Percent Full—Oldest records will be lost
|
AUD-LOG-LOW
|
Audit Log 80 Percent Full
|
AUTOLSROFF
|
Automatic Laser Shutoff Due To High Temperature
|
AUTORESET
|
Automatic System Reset
|
AUTOSW-AIS-SNCP
|
Automatic SNCP Switch caused by AIS
|
AUTOSW-LOP-SNCP
|
Automatic SNCP Switch Caused By LOP
|
AUTOSW-PDI-SNCP
|
Automatic SNCP Switch Caused By PDI
|
AUTOSW-SDBER-SNCP
|
Automatic SNCP Switch Caused By SDBER
|
AUTOSW-SFBER-SNCP
|
Automatic SNCP Switch Caused By SFBER
|
AUTOSW-UNEQ-SNCP
|
Automatic SNCP Switch Caused By UNEQ
|
AWG-DEG
|
AWG Temperature Degrade
|
AWG-FAIL
|
AWG Temperature Failure
|
AWG-OVERTEMP
|
AWG Over-Temperature
|
AWG-WARM-UP
|
AWG Warm Up
|
BAT-FAIL
|
Battery Failure
|
BAT-HGH-VLT
|
High Volt
|
BAT-LOW-VLT
|
Low Volt
|
BKUPMEMP
|
Primary Non-Volatile Backup Memory Failure
|
CARLOSS
|
Carrier Loss On The LAN
|
CASETEMP-DEG
|
Case Temperature Degrade
|
CKTDOWN
|
Signaling unable to set up circuit
|
CLDRESTART
|
Cold Restart
|
COMIOXC
|
IO Slot To XCON Communication Failure
|
COMM-FAIL
|
Plug-in Module Communication Failure
|
CONTBUS-A-18
|
TCC A To DCC A Processor Communication Failure
|
CONTBUS-B-18
|
TCC B To DCC B Processor Communication Failure
|
CONTBUS_A
|
Controller A To Shelf Slot Communication Failure
|
CONTBUS_B
|
Controller B To Shelf Slot Communication Failure
|
CTNEQPT-MISMATCH
|
Connection Equipment Mismatch
|
CTNEQPT-PBPROT
|
Interconnection Equipment Failure—Protect XC Payload Bus
|
CTNEQPT-PBWORK
|
Interconnection Equipment Failure—Working XC Payload Bus
|
DATAFLT
|
Software Fault—Data Integrity Fault
|
DBOSYNC
|
Standby Database Out of Sync
|
DS3-MISM
|
DS3 Frame Format Mismatch
|
DSP-COMM-FAIL
|
DSP Communication Failure
|
DSP-FAIL
|
DSP Failure
|
DUP-IPADDR
|
IP address already in use within the same DCC Area
|
DUP-NODENAME
|
Node name already in use within the same DCC area
|
E-W-MISMATCH
|
Both Ends Of Fiber Provisioned As East Or Both As West
|
E3-ISD
|
E3 Idle Condition
|
EHIBATVG
|
Extreme High Volt
|
ELWBATVG
|
Extreme Low Volt
|
EOC
|
RS-DCC Termination Failure
|
EQPT
|
Equipment Failure
|
EQPT-MISS
|
Replaceable Equipment/Unit is Missing
|
ERFI-P-CONN
|
Enhanced Remote Failure Indication—Path—Connectivity
|
ERFI-P-PAYLD
|
Enhanced Remote Failure Indication—Path—Payload
|
ERFI-P-SRVR
|
Enhanced Remote Failure Indication—Path—Server
|
ERROR-CONFIG
|
Error in Startup Configuration
|
ETH-LINKLOSS
|
Rear Panel Ethernet Link Removed
|
EXCCOL
|
Excess Collisions On The LAN
|
EXERCISE-RING-FAIL
|
Exercise Request on Ring Failed
|
EXERCISE-RING-REQ
|
Exercise Request on Ring
|
EXERCISE-SPAN-FAIL
|
Exercise Request on Span Failed
|
EXERCISE-SPAN-REQ
|
Exercise Request on Span
|
EXT
|
Failure Detected External To The NE
|
EXTRA-TRAF-PREEMPT
|
Extra Traffic Preempted
|
FAILTOSW
|
Failure To Switch To Protection
|
FAILTOSW-HO
|
Failure To Switch To Protection—High Order Path
|
FAILTOSW-LO
|
Failure To Switch To Protection—Low Order Path
|
FAILTOSWR
|
Failure To Switch To Protection—Ring
|
FAILTOSWS
|
Failure To Switch To Protection—Span
|
FAN
|
Fan Failure
|
FANDEGRADE
|
Partial Fan Failure
|
FE-AIS
|
Far End AIS
|
FE-DS1-MULTLOS
|
Far End Multiple DS1 LOS Detected On DS3
|
FE-DS1-NSA
|
Far End DS1 Equipment Failure—Non Service Affecting
|
FE-DS1-SA
|
Far End DS1 Equipment Failure—Service Affecting
|
FE-DS1-SNGLLOS
|
Far End Single DS1 LOS
|
FE-DS3-NSA
|
Far End DS3 Equipment Failure—Non Service Affecting
|
FE-DS3-SA
|
Far End DS3 Equipment Failure—Service Affecting
|
FE-E1-MULTLOS
|
Far end multiple E1 LOS detected on E3
|
FE-E1-NSA
|
Far end E1 eqpt fail non service affecting
|
FE-E1-SA
|
Far end E1 eqpt fail service affecting
|
FE-E1-SNGLLOS
|
Far end signal E1 LOS
|
FE-E3-NSA
|
Far end E3 eqpt fail non service affecting
|
FE-E3-SA
|
Far end E3 eqpt fail service affecting
|
FE-EQPT-NSA
|
Far End Common Equipment Failure—Non Service Affecting
|
FE-EXERCISING-RING
|
Far End Exercising Ring
|
FE-EXERCISING-SPAN
|
Far End Exercising Span
|
FE-FRCDWKSWPR-RING
|
Far End Working Facility Forced To Switch To Protection—Ring
|
FE-FRCDWKSWPR-SPAN
|
Far End Working Facility Forced To Switch To Protection—Span
|
FE-IDLE
|
Far End IDLE
|
FE-LOCKOUTOFPR-ALL
|
Far End Lockout Of Protection—All Spans
|
FE-LOCKOUTOFPR-RING
|
Far End Lockout Of Protection—Ring
|
FE-LOCKOUTOFPR-SPAN
|
Far End Lockout Of Protection—Span
|
FE-LOCKOUTOFWK-RING
|
Far End Lockout Of Working—Ring
|
FE-LOCKOUTOFWK-SPAN
|
Far End Lockout Of Working—Span
|
FE-LOF
|
Far End LOF
|
FE-LOS
|
Far End LOS
|
FE-MANWKSWPR-RING
|
Far End Manual Switch Of Working Facility To Protection—Ring
|
FE-MANWKSWPR-SPAN
|
Far End Manual Switch Of Working Facility To Protection—Span
|
FE-SDPRLF
|
APS Channel—Far End Protection Line Signal Degrade
|
FEC-MISM
|
FEC Mismatch
|
FEPRLF
|
Far End Protection Line Failure
|
FIBERTEMP-DEG
|
Fiber Temperature Degrade
|
FORCED-REQ
|
Forced Switch Request
|
FORCED-REQ-RING
|
Forced Switch Request On Ring
|
FORCED-REQ-SPAN
|
Forced Switch Request On Span
|
FRCDSWTOINT
|
Forced Switch To Internal Clock
|
FRCDSWTOPRI
|
Forced Switch To Primary Reference
|
FRCDSWTOSEC
|
Forced Switch To Second Reference
|
FRCDSWTOTHIRD
|
Forced Switch To Third Reference
|
FRNGSYNC
|
Free Running Synchronization Mode
|
FSTSYNC
|
Fast Start Synchronization Mode
|
FULLPASSTHR-BI
|
Bidirectional Full Pass Through Is Active
|
GAIN-HDEG
|
Optical Amplifier Gain Degrade High
|
GAIN-HFAIL
|
Optical Amplifier Gain Failure High
|
GAIN-LDEG
|
Optical Amplifier Gain Degrade Low
|
GAIN-LFAIL
|
Optical Amplifier Gain Failure Low
|
GCC-EOC
|
GCC Termination Failure
|
GE-OOSYNC
|
Gigabit Ethernet Out of Sync
|
HI-LASERBIAS
|
Equipment High Laser Bias
|
HI-RXPOWER
|
Equipment High Receive Power
|
HI-TXPOWER
|
Equipment High Transmit Power
|
HITEMP
|
High Temperature
|
HLDOVRSYNC
|
Holdover Synchronization Mode
|
HP-RFI
|
Remote Failure Indication—High Order—Remote Failure/Alarm Indication
|
HP-TIM
|
High Order—Trace Identifier Mismatch Failure
|
HP-UNEQ
|
Signal Label Mismatch Failure (SLMF)—Unequipped High Order—Path Unequipped
|
I-HITEMP
|
Industrial High Temperature
|
IMPROPRMVL
|
Improper Removal
|
INC-GFP-OUTOFFRAME
|
Out Of Frame Detected by Generic Framing Protocol (GFP) Receiver
|
INC-GFP-SIGLOSS
|
Client Signal Loss Frames Detected by GFP Receiver
|
INC-ISD
|
DS3 Idle Condition
|
INC-SIGLOSS
|
Incoming Signal Loss on Fibre Channel Interface
|
INC-SYNCLOSS
|
Incoming Synchronization Loss on Fibre Channel Interface
|
INC_GFP_SYNCLOSS
|
Client Synchronization Loss Frames Detected by GFP Receiver
|
INHSWPR
|
Inhibit Switch To Protect Request On Equipment
|
INHSWWKG
|
Inhibit Switch To Working Request On Equipment
|
INTRUSION-PSWD
|
Security Intrusion Attempt Detected—See Audit Log
|
INVMACADR
|
Invalid MAC Address
|
IOSCFGCOPY
|
Ios Config Copy In Progress
|
KB-PASSTHR
|
K Bytes Pass-Through Is Active
|
KBYTE-APS-CHANNEL-FAILURE
|
Kbyte Channel Failure
|
LAN-POL-REV
|
Lan Connection Polarity Reversed
|
LASER-APR
|
Laser Auto Power Reduction
|
LASERBIAS-DEG
|
Laser Bias Degrade
|
LASERBIAS-FAIL
|
Laser Bias Failure
|
LASEREOL
|
Laser Approaching End of Life
|
LASERTEMP-DEG
|
Laser Temperature Degrade
|
LKOUTPR-R
|
Lockout Of Protection—Ring
|
LKOUTPR-S
|
Lockout Of Protection—Span
|
LKOUTWK-R
|
Lockout Of Working—Ring
|
LKOUTWK-S
|
Lockout Of Working—Span
|
LMP-HELLODOWN
|
Link Management Protocol (LMP) Hello FSM to Control Channel down
|
LMP-NDFAIL
|
LMP Neighbor Discovery has failed
|
LO-RXPOWER
|
Equipment Low Receive Power
|
LO-TXPOWER
|
Equipment Low Transmit Power
|
LOA
|
Loss of Alignment
|
LOC
|
Loss of Channel
|
LOCKOUT-REQ
|
Lockout Switch Request On Facility or Equipment
|
LOCKOUT-REQ-RING
|
Lockout Switch Request On Ring
|
LOCKOUTOFPR
|
Lockout Of Protection
|
LOF
|
Loss Of Frame
|
LOM
|
Loss of Multi-Frame
|
LOS
|
Loss Of Signal
|
LOS-CONT
|
Loss Of Continuity
|
LP-PLM
|
Signal Label Mismatch Failure (SLMF)—PLM Low Order—Path Label Mismatch
|
LP-RFI
|
RFI—Low Order—Remote Failure/Alarm Indication
|
LP-TIM
|
TIM Low Order—Trace Identifier Mismatch Failure
|
LP-UNEQ
|
Signal Label Mismatch Failure (SLMF)—Unequipped Low Order—Path Unequipped
|
LPBKCRS
|
Cross-connect Loopback
|
LPBKDS1FEAC
|
DS1 Loopback Due To Far End Alarm and Control (FEAC) Command
|
LPBKDS3FEAC
|
DS3 Loopback Due To FEAC Command
|
LPBKDS3FEAC-CMD
|
DS3 Loopback Command Sent To Far End
|
LPBKE1FEAC
|
E1 loopback due to FEAC command
|
LPBKE3FEAC
|
E3 loopback due to FEAC command
|
LPBKE3FEAC-CMD
|
E3 loopback command sent to far end
|
LPBKFACILITY
|
Facility Loopback
|
LPBKTERMINAL
|
Terminal Loopback
|
MAN-REQ
|
Manual Switch Request
|
MANRESET
|
Manual System Reset
|
MANSWTOINT
|
Manual Switch To Internal Clock
|
MANSWTOPRI
|
Manual Switch To Primary Reference
|
MANSWTOSEC
|
Manual Switch To Second Reference
|
MANSWTOTHIRD
|
Manual Switch To Third Reference
|
MANUAL-REQ-RING
|
Manual Switch Request On Ring
|
MANUAL-REQ-SPAN
|
Manual Switch Request On Span
|
MEA
|
Mismatch Of Equipment And Attributes
|
MEM-GONE
|
Free Memory On Card Near Zero
|
MEM-LOW
|
Free Memory On Card Very Low
|
MFGMEM
|
Manufacturing Data Memory (EEPROM Failure)
|
MS-AIS
|
AIS—Multiplex Section—Alarm Indication Signal
|
MS-EOC
|
Multiplex Section DCC Termination Failure
|
MS-RFI
|
RFI—Multiplex Section—Remote Failure/Alarm Indication
|
MSSP-OOSYNC
|
Procedural Error—MS-SPRing out of sync
|
NO-CONFIG
|
No Startup Configuration
|
NTWTPINC
|
Network Topology Incomplete
|
OCHNC-ACTIV-FAIL
|
Optical Channel Activation Failure
|
OCHNC-DEACTIV-FAIL
|
Optical Channel Deactivation Failure
|
OCHNC-FAIL
|
Optical Channel Connection Failure
|
OCHNC-INC
|
Optical Channel Incomplete
|
ODUK-AIS-PM
|
ODUk: Alarm Indication Signal
|
ODUK-BDI-PM
|
ODUk: PM Backward Defect Indication
|
ODUK-LCK-PM
|
ODUk: Locked Defect —Performance Monitoring (PM)
|
ODUK-OCI-PM
|
ODUk: Open Connection Indication
|
ODUK-SD-PM
|
ODUk: Signal Degrade
|
ODUK-SF-PM
|
ODUk: Signal Failure
|
ODUK-TIM-PM
|
ODUk: Trail Trace Identifier Mismatch
|
OOU-TPT
|
Out of Use—Transport Failure
|
OPTNTWMIS
|
Optical Network Type Mismatch
|
OPWR-HDEG
|
Optical Power Degrade High
|
OPWR-HFAIL
|
Optical Power Failure High
|
OPWR-LDEG
|
Optical Power Degrade Low
|
OPWR-LFAIL
|
Optical Power Failure Low
|
OTUK-AIS
|
OTUk: Alarm Indication Signal
|
OTUK-BDI
|
OTUk: Backward Defect Indication
|
OTUK-LOF
|
OTUk: Loss Of Frame
|
OTUK-SD
|
OTUk: Signal Degrade
|
OTUK-SF
|
OTUk: Signal Failure
|
OTUK-TIM
|
OTUk: Trail Trace Identifier Mismatch
|
OUT-OF-SYNC
|
8B10B Out of Sync
|
PDI-P
|
Payload Defect Indication—Path
|
PEER-NORESPONSE
|
Peer Card Not Responding
|
PORT-CODE-MISM
|
Pluggable port security code mismatch
|
PORT-COMM-FAIL
|
Module Communication Failure
|
PORT-MISMATCH
|
Pluggable port rate mismatch
|
PORT-MISSING
|
Pluggable port missing
|
PRC-DUPID
|
Duplicate Node ID
|
PROTNA
|
Protection Unit Not Available
|
PTIM
|
Payload Type Identifier Mismatch
|
PWR-REDUN
|
Redundant Power Capability Lost
|
RAI
|
Remote Alarm Indication
|
RCVR-MISS
|
Facility Termination Equipment—Receiver Missing
|
RFI
|
Remote Failure Indication
|
RFI-L
|
Remote Failure Indication—Line
|
RING-ID-MIS
|
Ring Id Mismatch
|
RING-MISMATCH
|
Far End Of Fiber Is Provisioned With Different Ring ID
|
RING-SW-EAST
|
Ring Switch Is Active On The East Side
|
RING-SW-WEST
|
Ring Switch Is Active On The West Side
|
RSVP-HELLODOWN
|
RSVP Hello FSM to Neighbor down
|
RUNCFG-SAVENEED
|
Need to Save Running Config
|
SD
|
Signal Degrade
|
SD-L
|
Bit Error Rate (BER) Threshold Exceeded For Signal Degrade—Line
|
SDBER-EXCEED-HO
|
BER Threshold Exceeded For Signal Degrade—High Order
|
SF
|
Signal Failure
|
SF-L
|
BER Threshold Exceeded For Signal Failure—Line
|
SFBER-EXCEED-HO
|
BER Threshold Exceeded For Signal Failure—High Order
|
SFTWDOWN
|
Software Download In Progress
|
SH-INS-LOSS-VAR-DEG-HIGH
|
Shutter Insertion Loss Variation Degrade High
|
SH-INS-LOSS-VAR-DEG-LOW
|
Shutter Insertion Loss Variation Degrade Low
|
SHUTTER-OPEN
|
Shutter Open
|
SNTP-HOST
|
Simple Network time Protocol (SNTP) Host Failure
|
SPAN-SW-EAST
|
Span Switch Is Active On The East Side
|
SPAN-SW-WEST
|
Span Switch Is Active On The West Side
|
SQM
|
Sequence Mismatch
|
SQUELCH
|
Ring Is Squelching Traffic
|
SQUELCH-PATH
|
Squelching Path
|
SQUELCHED
|
Equipment Squelched
|
SSM-DUS
|
Do Not Use For Synchronization
|
SSM-FAIL
|
Failed To Receive Synchronization Status Message
|
SSM-LNC
|
ITU-T G.812—Local Node Clock traceable
|
SSM-OFF
|
Synchronization Status Messages Are Disabled On This Interface
|
SSM-PRC
|
ITU-T G.811—Primary Reference Clock traceable
|
SSM-PRS
|
Stratum 1 Primary Reference Source Traceable
|
SSM-RES
|
Reserved For Network Synchronization Use
|
SSM-NCS-TN
|
ITU-T G.812—Transit Node Clock traceable
|
SSM-SETS
|
ITU-T G.813—Synchronous Equipment Timing Source traceable
|
SSM-SMC
|
NCS Minimum Clock Traceable
|
SSM-ST2
|
Stratum 2 Traceable
|
SSM-ST3
|
Stratum 3 Traceable
|
SSM-ST3E
|
Stratum 3E Traceable
|
SSM-ST4
|
Stratum 4 Traceable
|
SSM-STU
|
Synchronized—Traceability Unknown
|
SSM-TNC
|
Transit Node Clock Traceable
|
SWMTXMOD
|
Switching Matrix Module Failure
|
SWTOPRI
|
Switch To Primary Reference
|
SWTOSEC
|
Switch To Second Reference
|
SWTOTHIRD
|
Switch To Third Reference
|
SYNC-FREQ
|
Synchronization Reference Frequency Out Of Bounds
|
SYNCPRI
|
Primary Synchronization Reference Failure
|
SYNCSEC
|
Secondary Synchronization Reference Failure
|
SYNCTHIRD
|
Third Synchronization Reference Failure
|
SYSBOOT
|
System Reboot
|
TIM
|
TIM Section—Trace Identifier Mismatch Failure
|
TIM-MON
|
TIM Section Monitor—Trace Identifier Mismatch Failure
|
TPTFAIL
|
Transport layer failure
|
TRMT
|
Transmit Failure
|
TRMT-MISS
|
Facility Termination Equipment—Transmitter Missing
|
TU-AIS
|
AIS—Tributary Unit—Alarm Indication Signal
|
TU-LOP
|
LOP—Tributary Unit—Loss of Pointer
|
TUNDERRUN
|
Ethernet Transmit First In First Out Underrun
|
TX-AIS
|
Alarm Indication Signal in TX
|
TX-RAI
|
Remote Alarm Indication in TX
|
UNC-WORD
|
FEC Uncorrected Word
|
VCG-DEG
|
VCAT Group Degraded
|
VCG-DOWN
|
VCAT Group Down
|
VOA-HDEG
|
Variable Optical Attenuator Degrade High
|
VOA-HFAIL
|
Variable Optical Attenuator Failure High
|
VOA-LDEG
|
Variable Optical Attenuator Degrade Low
|
VOA-LFAIL
|
Variable Optical Attenuator Failure Low
|
WKSWPR
|
Switched To Protection
|
WTR
|
Wait To Restore
|
WVL-MISMATCH
|
Equipment Wavelength Mismatch
|