Cisco NCS TL1 Command Guide, Release 10.x.x
Chapter 27, Access Identifiers

Table Of Contents

Access Identifiers

27.1  ALL

27.2  AidUnionId

27.3  AidUnionId1

27.4  BAND

27.5  BANDWL

27.6  BITS

27.7  CHANNEL

27.8  CHGRP

27.9  COM

27.10  CrossConnectId

27.11  CrossConnectId1

27.12  ENV

27.13  EQPT

27.14  ETH

27.15  FACILITY

27.16  FPLINE

27.17  IPADDR

27.18  LINE

27.19  LINEWL

27.20  LNKTERM

27.21  MSSPR

27.22  OPM

27.23  OSC

27.24  PRSLOT

27.25  RFILE

27.26  SHELF

27.27  SYN

27.28  SYN_SRC

27.29  SYNC_REF

27.30  SYNCSW

27.31  UDC

27.32  VC

27.33  WDMANS

27.34  WLEN

27.35  CTC Port Numbers and TL1 Aids


Access Identifiers


This chapter describes the access identifiers (AIDs) of TL1 commands and autonomous messages for the Cisco NCS 2002 and Cisco NCS 2006.

The AID code directs an input command to its intended physical or data entity inside the network element (NE). Equipment modules and facilities are typical examples of entities addressed by the access code.

27.1  ALL

The table lists the ALL AIDs and patterns.

Table 27-1 ALL

AID
Pattern

AidUnionId

FACILITY

VC

AidUnionId1

MS-SPRing

ACHAN

ACHAN[-{1-50}]-{2-7}-{1}-{1}

AGGR

AGGR-[SLOT]-[APPM]-[PORT]

AGGR[-{1-50}]-{2-7}-{1}-{1}

BAND

ALL

BAND[-{1-50}]-{1-6,12-17}-{1-4}-ALL

BAND[-{1-50}]-{1-6,12-17}-{1-4}-{RX,TX}

BAND[-{1-50}]-{1-6,12-17}-{1}-ALL

BAND[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}

BANDWL

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-1530.33

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-ALL

BANDWL-[{1-50}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-<WLEN>

BANDWL-[{1-50}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-ALL

BITS

ALL

BITS-ALL

BITS[<SHELFID>]-ALL

BITS[<SHELFID>]-{1,2}

SYNC[<SHELFID>]-BITS{1,2}

CHANNEL

ALL

CHAN[-{1-50}]-{1-6,12-17}-ALL

CHAN[-{1-50}]-{1-6,12-17}-{1-32}-ALL

CHAN[-{1-50}]-{1-6,12-17}-{1-32}-{RX,TX}

CHAN[-{1-50}]-{1-6,12-17}-{1-32}-{RX,PT}

CHAN[-{1-50}]-{1-5,12-16}-{1-40}-ALL

CHAN[-{1-50}]-{1-5,12-16}-{1-40}-{RX,TX}

CHAN[-{1-50}]-{1-5,12-16}-{1-40}-{RX,PT}

CHAN[-{1-50}]-{1-6,12-17}-{1-4}-ALL

CHAN[-{1-50}]-{1-6,12-17}-{1-4}-{RX,TX}

CHAN[-{1-50}]-{1-6,12-17}-{2,3}

CHAN[-{1-50}]-{1-6,12-17}-{5}

CHAN[-{1-50}]-{1-6,12-17}-{9,10}

CHAN[-{1-50}]-{1-6,12-17}-{3,4}-{1}

CHAN[-{1-50}]-{1-6,12-17}-{21,22}-{1}

CHAN-[{1-50}-]{1-6,12-17}-{1-32}-{RX,TX,PT}
CHAN-[{1-50}-]{1-6,12-17}-{1-32}-ALL
CHAN[-{1-50}]-{1-6,12-17}-{19}-{1}
CHAN[-{1-50}]-{1-6,12-17}-{17,18}-{1}
CHAN-[SLOT]-[PORT]
CHAN[-{1-50}]-{2-7}-{1-10}-{1}

COM

Common

CrossConnectId

FACILITY

CrossConnectId1

VCM

FACILITY

VC

ENV

ALL

ENV-IN-ALL

ENV-IN[-{1-50}]-ALL

ENV-IN[-{1-50}]-{1-20}

ENV-IN[-{1-50}]-{1-32}

ENV-IN[-{1-50}]-{1-3}

ENV-IN[-{1-50}]-{1-4}

EQPT

ALL

AIP-ALL

AIP[-{1-50}]

BIC-ALL

BIC[-{1-50}]-ALL

BIC[-{1-50}]-{A,B}

BP-ALL

BP[-{1-50}]

FAN-ALL

FAN[-{1-50}]

PPM-{1-6,12-17}-1

FACILITY

ALL

FAC[-{1-50}]-{1-4,14-17}-{1-12}

FAC[-{1-50}]-{1-6,12-17}-1

FAC[-{1-50}]-{1-6,12-17}-ALL

FAC[-{1-50}]-{1-6,12-17}-{0-11}

FAC[-{1-50}]-{1-6,12-17}-{0-1}

FAC[-{1-50}]-{1-6,12-17}-{1-50,14,16,18,20,22,24,26,28,30,32,34,36}

FAC[-{1-50}]-{1-6,12-17}-{1-50,14,16,18,20,22,24}

IPADDR

111.222.333.444

LINE

LINE[-{1-50}]-{1-6,12-17}-{1-2}-ALL LINE[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}

LINE[-{1-50}]-{1-6,12-17}-{1-3}-ALL

LINE[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}

LINE[-{1-50}]-{8,10}-{1}-ALL

LINE[-{1-50}]-{8,10}-{1}-{RX,TX}

LINE-[{1-50}-]{1-6,12-17}-{1}-{RX,TX}(COM)

LINE-[{1-50}-]{1-6,12-17}-{2}-{RX,TX}(OSC)

LINE-[{1-50}-]{1-6,12-17}-{3}-{RX,TX}(LINE)

LINE-[{1-50}-]{1-6,12-17}-{1-3}-ALL

LINE-[{1-50}-]{1-6,12-17}-{1}-{RX,TX}(LINE)

LINE-[{1-50}-]{1-6,12-17}-{2}-{RX,TX}(COM)

LINE-[{1-50}-]{1-6,12-17}-{3}-{RX,TX}(OSC)

LINE-[{1-50}-]{1-6,12-17}-{4}-{RX,TX}(DC)

LINE-[{1-50}-]{1-6,12-17}-{1-4}-ALL

LINE-[{1-50}-]{1-6,12-17}-1-RX (For input OTS)

LINE-[{1-50}-]{1-6,12-17}-1-ALL

LINEWL

LINEWL[-{1-50}]-{1-6,8,10,12-17}-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-<WLEN>

LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-<WLEN>

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-<WLEN>

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}- <WLEN>

LINEWL[-{1-50}]-{1-6,12-17}-{1,3,4}-{RX,TX} -ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1,3,4}-{RX,TX} -<WLEN>

LINEWL-[{1-50}]-{1-5,12-16}-{1-8}-{RX}-<WLEN>

LINEWL-[{1-50}]-{1-5,12-16}-{9}-{RX,TX}-<WLEN>

LINEWL-[{1-50}]-{1-5,12-16}-{10}-{TX}-<WLEN>

LINEWL-[{1-50}]-{1-5,12-16}-{11}-{RX,TX}-<WLEN>

LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-<LABEL>

MS-SPRing

MSSPR-RINGID

ODU0

ODU0[-{1-50}]-{1-6,12-17}-{1-10}-{1}-{1-4}-{1-2}

OPM

ALL

OPM[-{1-50}]-{1-5,12-16}-<WLEN>

OPM[-{1-50}]-{1-5,12-16}-ALL

OSC

OSC-RINGID

PRSLOT

NULL

SLOT-1

SLOT-13

SLOT-15

SLOT-17

SLOT-3

SLOT-5

RPRIF

ALL

RPRIF-{1-6,12-17}-0

RFILE

RFILE-DB

RFILE-LOG

RFILE-PKG

RFILE-COMPDB

SHELF

SHELF-ALL

SHELF-{1-50}

SYN

SYNC-NE

SYN_SRC

BITS-1

BITS-2

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-{1-4}

SYNC_REF

SYNC-ALL

SYNC-NE

SYNC-{BITS1,BITS2}

SYNCSW

INT

PRI

SEC

UDC

UDC-{F,DCC}-{A,B}

VC

VC11-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-4}VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}VC11-{1-6,12-17}-1-1-{1-7}-{1-2}VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-4}VC12-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-3}VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}VC12-{1-6,12-17}-1-1-{1-7}-{1-2}VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}VC3-{1-14,14-17}-{1-12}-1-{1-3}VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}VC3-{1-4,14-17}-{1-8}-1-{1-3}VC3-{1-6,12-17}-1-{1-16}-{1-3}VC3-{1-6,12-17}-1-{1-4}-{1-3}VC3-{1-6,12-17}-{1-4}-1-{1-3}VC3-{1-6,12-17}-{1-4}-{1-3}VC4-{1-4,11-14}-{1-16}-1VC4-{1-4,11-14}-{1-16}-{1,5,9,13}VC4-{1-4,11-14}-{1-16}-{1,9}VC4-{1-4,11-14}-{1-4}-1

VCFAC

VCFAC[-{1-50}]-{2-7}-{1-2}

VFAC

VFAC[-{1-50}]-{2-7}-{1-10}-1

VCHAN

VCHAN[-{1-50}]-{2-7}-{1-2}

VLINE

VLINE[-{1-50}]-{2-7}-{1-2}-{1}-{1-12}

WDMANS

WDMSIDE-{UNKNOWN,A,B,C,D,E,F,G,H}

WDMNODE

WLEN

WLEN-{E,W}-{ADD,DROP,EXP}-{1530.33,1531.12,1531.90,1532.68,1534.25,1535.04,1535.82,
1536.61,1538.19,1538.98,1539.77,1540.56,1542.14,1542.94,1543.73,1544.53,1546.12,
1546.92,1547.72,1548.51,1550.12,1550.92,1551.72,1552.52,1554.13,1554.94,1555.75,1556.55,
1558.17,1558.98,1559.79,1560.61}


27.2  AidUnionId

Table 27-2 lists the AidUnionId AIDs and patterns.

Table 27-2 AidUnionId 

AID
Patterns
Facility

ACHAN[-{1-50}]-{2-7}-{1}-{1}

AGGR[-{1-50}]-{2-7}-{1}-{1}

CHAN[-{1-50}]-{2-7}-{2}

CHAN[-{1-50}]-{2-7}-{1-10}-{1}

E1-{2}-{1-21}

E3-{2}-{1-3}

FAC-{1-4,11-14}-ALL

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4,11-14}-{1-4}-{1-4}-{1}

FAC-{1-4,14-17}-{1-8}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-ALL

FAC-{1-6,12-17}-{0-11}

FAC-{1-6,12-17}-{0-1}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,
30,32,34,36}

FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}

FAC-{1-6,12-17}-{1-12}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1-6}

FAC-{1-6,12-17}-{1}

FAC-{1-6}-ALL

FAC-{5,6,12,13}-{1}

FAC-{5-6}-{1-28}

FAC-{5-6}-{1-3}

FAC-{8,10}-{1}

FSTE-{1,2,5,6}-{0-7}

FSTE-{1,2,5,6}-{1-8}

FSTE-{1}-{0-7}

FSTE-{1}-{1-8}

STM1-{2}-{1-2}-{1}

STM1-{3,4}-{1-2}-{1}

STM4-{2}-{1-2}-{1}

STM4-{3,4}-{1-2}-{1}

STM16-{3,4}-{1-2}-{1}

VFAC-{1,2,5,6}-{0-1}

VFAC-{1,2,5,6}-{1-8}

VFAC-{1-4,11-14}-{1-4}-{1-4}-1

VFAC-{1-6,12-17}-{0-1}

VFAC-{1-6,12-17}-{1,2}

VFAC-{1-6,12-17}-{1,2}-{1,8}

VFAC-{1}-{0-1}

VFAC-{1}-{1-8}
VFAC[-{1-50}]-{2-7}-{1-10}-{1}
VLINE[-{1-50}]-{2-7}-{1-2}-{1}-{1-12}
VC

VC11-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-1-{1-7}-{1-2}

VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-4}

VC12-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-1-{1-7}-{1-2}

VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC3-{1-14,14-17}-{1-12}-1-{1-3}

VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}

VC3-{1-4,14-17}-{1-8}-1-{1-3}

VC3-{1-6,12-17}-1-{1-16}-{1-3}

VC3-{1-6,12-17}-1-{1-4}-{1-3}

VC3-{1-6,12-17}-{1-4}-1-{1-3}

VC3-{1-6,12-17}-{1-4}-{1-3}

VC4-{1-4,11-14}-{1-16}-1

VC4-{1-4,11-14}-{1-16}-{1,5,9,13}

VC4-{1-4,11-14}-{1-16}-{1,9}

VC4-{1-4,11-14}-{1-4}-1

VC4-{1-4,11-14}-{1-4}-{1,17,33,49}

VC4-{1-4,11-14}-{1-4}-
{1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61}

VC4-{1-4,11-14}-{1-4}-{1,9,17,25,33,41,49,57}

VC4-{1-4,11-14}-{1-4}-{1-64}

VC4-{1-4,14-17}-1

VC4-{1-4,14-17}-1-1

VC4-{1-4,14-17}-{1-12}-1

VC4-{1-4,14-17}-{1-4}-1

VC4-{1-4,14-17}-{1-4}-{1-2}

VC4-{1-4,14-17}-{1-4}-{1-3}

VC4-{1-4,14-17}-{1-4}-{1-4}

VC4-{1-4,14-17}-{1-8}-1

VC4-{1-6,12-17}-1

VC4-{1-6,12-17}-1-1

VC4-{1-6,12-17}-1-
{1,2,3,5,6,7,9,10,11,13,14,15}

VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}

VC4-{1-6,12-17}-1-{1,5,9,13}

VC4-{1-6,12-17}-1-{1-16}

VC4-{1-6,12-17}-1-{1-2}

VC4-{1-6,12-17}-1-{1-3}

VC4-{1-6,12-17}-1-{1-4}

VC4-{1-6,12-17}-1-{1-9}

VC4-{1-6,12-17}-{1-4}

VC4-{1-6,12-17}-{1-4}-1


27.3  AidUnionId1

Table 27-3 lists the AidUnionId1 AIDs and patterns.

Table 27-3 AidUnionId1 

AID
Patterns

MS-SPRing

ALL

MSSPR-RINGID


27.4  BAND

The BAND AID is used to access Optical Multiplex Section (OMS) layer of optical networking units. Table 27-4 lists the BAND AIDs and their descriptions.

AID for OCH interface of CXP port on 100G-LC-C card: ACHAN-[SLOT]-[PPM]-[PORT].

AID for fixed trunk on 100G-LC-C card: CHAN-[SLOT]-[PORT].

Table 27-4 BAND 

Pattern
Description

ALL

All of the OMSs of the NE. The ALL AID is applicable for retrieve-only commands.

BAND[-{1-50}]-{1-6,12-17}-{1-4}-ALL

All the channels in a Band OADM (AD-1B-xx.x, AD-4B-xx.x) unit.

BAND[-{1-50}]-{1-6,12-17}-{1-4}-{RX,TX}

The Receive/Transmit channels in a Band OADM (AD-1B-xx.x, AD-4B-xx.x) unit.

BAND[-{1-50}]-{1-6,12-17}-{1}-ALL

All the channels in an Optical Multiplexer/Demultiplexer (4MD-xx.x) unit.

BAND[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}

The Receive/Transmit channels in an Optical Multiplexer/Demultiplexer (4MD-xx.x) unit.


27.5  BANDWL

Band wavelength. Identifies a wavelength channel included in any of the lower layer OMS facilities. Table 27-5 lists the BANDWL AIDs and their descriptions.

Table 27-5 BANDWL 

Pattern
Description

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-1530.33

Identifies an allocated wavelength channel included in any of the lower layer OMS facilities.

BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-ALL

Identifies all of the allocated wavelength channels included in any of the lower layer OMS facilities.

BANDWL-[{1-50}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-<WLEN>

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the endpoints of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-
[WAVELENGTH]. WAVELENGTH is in the form of 15xx.yy.

BANDWL-[{1-50}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-ALL

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the endpoints of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-
[WAVELENGTH]. WAVELENGTH is in the form of 15xx.yy.


27.6  BITS

AID for building integrated timing supply (BITS). Table 27-6 lists the BITS AIDs and their descriptions.

Table 27-6 BITS 

Pattern
Description

ALL

The ALL AID is applicable to RTRV commands only (RTRV-BITS, RTRV-ALM-BITS, and RTRV-COND-BITS). The All AID is equivalent to BITS-ALL for these commands. For RTRV-ALM-SYNCN and RTRV-COND-SYNCN, the ALL AID translates to BITS-ALL, SYNC-BITS1, and SYNC-BITS2.

BITS-ALL

BITS AIDs of both BITS-1 and BITS-2 in the RTRV-BITS command.

BITS[<SHELFID>]-ALL

BITS shelf ID of both BITS-1 and BITS-2 in the RTRV-BITS command.

BITS[<SHELFID>]-{1,2}

Individual BITS AID.

SYNC[<SHELFID>]-BITS{1,2}

BITS-OUT AIDs of BITS-1 and BITS-2. These AIDs are applicable only in ED-BITS and RTRV-BITS commands and are used for setting and retrieving the BITS-OUT parameters.


27.7  CHANNEL

Accesses the Optical Channel (OCH) layer of optical networking/client units. Table 27-9 lists the CHANNEL AIDs and their descriptions.

Table 27-7 CHANNEL 

CHANNEL Values
Description

ALL

ALL OCHs of the NE. The ALL AID is applicable for retrieve-only commands.

ACHAN[-{1-50}]-{2-7}-{1}-{1}

Identifies the OCH Facility of Aggregate port of 100G-LC-C Card.

CHAN[-{1-50}]-{2-7}-{2}

Identifies the Fixed Trunk or the Coherent Trunk on 100G-LC-C Card.

CHAN[-{1-50}]-{1-6,12-17}-ALL

All the channels of an Optical Transponder/Muxponder. The format is CHAN-[SLOT]-ALL

CHAN[-{1-50}]-{1-6,12-17}-{1-32}-
ALL

All the channels in an Optical Multiplexer/Demultiplexer 32WSS unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-ALL.

CHAN[-{1-50}]-{1-6,12-17}-{1-32}-
{RX,TX}

The Receive/Transmit channels in an Optical Multiplexer/Demultiplexer (32DMX, 32MUX) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].

CHAN[-{1-50}]-{1-6,12-17}-{1-32}-
{RX,PT}

The Receive/Pass-through channels in an Optical 32WSS unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].

CHAN[-{1-50}]-{1-5,12-16}-{1-40}-A

LL

All the channels in Optical Multiplexer/Demultiplexer/WSS (40Ch) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-ALL.

CHAN[-{1-50}]-{1-5,12-16}-{1-40}-{

RX,TX}

The receive/transmit channels in an Optical Multiplexer/Demultiplexer (40Ch) unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].

CHAN[-{1-50}]-{1-5,12-16}-{1-40}-{

RX,PT}

The Receive/Pass-through channels in an Optical WSS (40Ch) unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].

CHAN[-{1-50}]-{1-6,12-17}-{1-4}-ALL

All the Channels in an OADM (AD-1C-xx.x, AD-2C-xx.x, AD-4C-xx.x) unit or Optical Multiplexer/Demultiplexer (4MD-xx.x) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-ALL.

CHAN[-{1-50}]-{1-6,12-17}-{1-4}-
{RX,TX}

The Receive/Transmit Channels in an OADM (AD-1C-xx.x, AD-2C-xx.x, AD-4C-xx.x) unit or Optical Multiplexer/Demultiplexer (4MD-xx.x) unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].

CHAN[-{1-50}]-{1-6,12-17}-{2,3}

A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G, TXP_MR_10E, and TXP_MR_2.5G cards use CHAN-[SHELF]-SLOT-2 for the one NCS Facility. The TXPP_MR_2.5G card uses CHAN-[SHELF]-SLOT-{2,3} for the two NCS Facilities. The format is CHAN-[SHELF]-[SLOT]-[PORT].

CHAN[-{1-50}]-{1-6,12-17}-{5}

A single channel of an Optical Muxponder. The TXP_MR_10G and TXP_MR_10E cards use CHAN-[SHELF]-SLOT-5 for the one NCS facility. The TXP_MR_10G uses the CHAN-[SHELF]-SLOT-5 for the one NCS facility. The format is CHAN-[SHELF]-[SLOT]-[PORT].

CHAN[-{1-50}]-{1-6,12-17}-{9,10}

A single channel of an Optical Muxponder. The MXP_MR_10DME_C and MXP_2.5G_10G cards use CHAN-[SHELF]-SLOT-9 for the one NCS Facility. The MXPP_2.5G_10G card uses CHAN-[SHELF]-SLOT-{9,10} for the two NCS Facilities. The format is CHAN-[SHELF]-[SLOT]-[PORT].

CHAN[-{1-50}]-{1-6,12-17}-{3,4}-{1}

A single channel of an Optical Muxponder. The 10GE-XP uses CHAN-[SHELF]-SLOT-{3,4}-1 for the two NCS facilities. The format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].

CHAN[-{1-50}]-{1-6,12-17}-{21,22}-{

1}

A single channel of an Optical Muxponder. The GE-XP uses CHAN-[SHELF]-SLOT-{11,12}-1 for the two NCS facilities. The format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].

CHAN-[{1-50}-]{1-6,12-17}-{1-32}-

{RX,TX,PT}

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION].

CHAN-[{1-50}-]{1-6,12-17}-{1-32}-

ALL

OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-[WAVELENGTH (in the form of 15xx.yy)].

CHAN[-{1-50}]-{1-6,12-17}-{19}-{1}

A single channel of an ADM-10G card. ADM-10G uses CHAN-[SHELF]-SLOT-19 for one NCS Facility. Format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].

CHAN[-{1-50}]-{1-6,12-17}-{17,18}-

{1}

The NCS interlinks between two peer ADM-10G cards. ADM-10G uses CHAN-[SHELF]-SLOT-{17,18} for the two NCS interlinks Facilities. Format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].

CHAN[-{1-50}]-{1-6,12-17}-{19}-{1}

A single channel of an ADM-10G card. ADM-10G uses CHAN-[shelf]-slot-19 for the 1 NCS Facility. Format is CHAN-[shelf]-[slot]-[ppm]-[port].

CHAN[-{1-50}]-{2-7}-{1-10}-{1}

Identifies OCH interface of SFP+ ports on 10x10G-LC and CFP ports on CFP-LC.

CHAN[-{1--0}]-{1-6,12-17}-{17,18}-{1

The NCS Interlinks between 2 peer ADM-10G cards. ADM-10G uses CHAN-[shelf]-slot-{17,18} for the 2 NCS Interlinks Facilities. Where format is CHAN-[shelf]-[slot]-[ppm]-[port]. In Release 9.0 or later, Port Number 18 can be used as an optical channel in the single card mode, the AID and the format remain the same.

PCHAN-ALL

All the Channels in all the Passive patch panel module where format is PCHAN-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

PCHAN-{1-96}-ALL

All the Channels in a Passive patch panel module where format is PCHAN-[id]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

PCHAN-{1-96}-{1-4}-ALL

All the TX and RX Channels in a port of 15216-FLD-xx-x, passive modules where format is PCHAN-[id]-[port]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

PCHAN-{1-96}-{1-4}-{RX-TX}

All the TX and RX Channels in a port of 15216-FLD-xx-x, passive modules where format is PCHAN-[id]-[port]-[direction]. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

PCHAN-{1-96}-{1-40}-ALL

All the TX and RX Channels in a port of 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

PCHAN-{1-96}-{1-40}-{RX,TX}

The Recieve/Transmit Channels in a 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-[direction]. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

PCHAN-{1-96}-{1-40}-ALL

All the TX and RX Channels in a port of 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

PCHAN-{1-96}-{1-40}-{RX,TX}

The Recieve/Transmit Channels in a 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-[direction]. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.

VCHAN[-{1-50}]-{2-7}-{1-2}

Indentifies the OCH Facility of the Backplane Virtual ports on 100G-LC-C card.

FPCHAN-{1-126}-{1-48}-{RX-TX}

All the ADD/DROP ports of MD-48-EVEN/MD-48-ODD passive module where format is FPCHAN-[id]-[port]-[DIR}.


27.8  CHGRP

AID for the Channel Group (CHGRP). Table 27-8 lists the CHGRP AIDs and their descriptions.

Table 27-8 CHGRP

Pattern
Description

ALL

The ALL aid is applicable for RTRV-only commands, basically the RTRV-rr type of commands. For example, RTRV-CHGRP with ALL aid returns all CHGRP ports on the GE_XP and 10GE_XP cards.

CHGRP-[{1-50}]-{1-6,12-17}-{1-11}

Channel group AID on GE_XP and 10GE_XP cards. The format is CHGRP-[SHELF]-[SLOT]-[CHGRP]


27.9  COM

Table 27-9 lists the common (COM) AIDs and their descriptions.

Table 27-9 COM 

Pattern
Description

COM

Common


27.10  CrossConnectId

Table 27-10 lists the CrossConnectId AIDs and their descriptions.

Table 27-10 CrossConnectId 

AID
Pattern

FACILITY

E1-{2}-{1-21}

E3-{2}-{1-3}

FAC-{1-4,11-14}-ALL

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4,11-14}-{1-4}-{1-4}-{1}

FAC-{1-4,14-17}-{1-8}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-ALL

FAC-{1-6,12-17}-{0-11}

FAC-{1-6,12-17}-{0-1}

FAC-{1-6,12-17}-{1-50,14,16,18,20,22,24,26,28,
30,32,34,36}

FAC-{5,6,12,13}-{1}

FAC-{5-6}-{1-28}

FAC-{5-6}-{1-3}

FAC-{8,10}-{1}

FSTE-{1,2,5,6}-{0-7}

FSTE-{1,2,5,6}-{1-8}

FSTE-{1}-{0-7}

FSTE-{1}-{1-8}

STM1-{2}-{1-2}-{1}

STM1-{3,4}-{1-2}-{1}

STM4-{2}-{1-2}-{1}

STM4-{3,4}-{1-2}-{1}

STM16-{3,4}-{1-2}-{1}

VFAC-{1,2,5,6}-{0-1}

FACILITY (cont.)

FAC-{1-6,12-17}-{1-50,14,16,18,20,22,24}

FAC-{1-6,12-17}-{1-50}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1-6}

FAC-{1-6,12-17}-{1}

FAC-{1-6}-ALL

VFAC-{1,2,5,6}-{1-8}

VFAC-{1-4,11-14}-{1-4}-{1-4}-1

VFAC-{1-6,12-17}-{0-1}

VFAC-{1-6,12-17}-{1,2}

VFAC-{1-6,12-17}-{1,2}-{1,8}

VFAC-{1}-{0-1}

VFAC-{1}-{1-8}

27.11  CrossConnectId1

Table 27-11 lists the CrossConnectId1 AIDs and their descriptions.

AID for CXP port on 100G-LC-C: AGGR[-{1-50}]-{2-7}-{1}-{1}.

AID for fixed trunk on 100G-LC-C: CHAN-[SLOT]-[PORT].

Table 27-11 CrossConnectId1 

AID
Pattern

EQPT

ALL

AIP-ALL

AIP[-{1-50}]

BIC-ALL

BIC[-{1-50}]-ALL

BIC[-{1-50}]-{A,B}

BP-ALL

BP[-{1-50}]

FAN-ALL

FAN[-{1-50}]

PIM[-{1-50}]-{1-4,11-14}-ALL

PIM[-{1-50}]-{1-4,11-14}-{1-4}

PPM[-{1-50}]-1-{1,2}

PPM[-{1-50}]-2-{1,2}

PPM[-{1-50}]-{1-4,11-14}-{1-4}-ALL

PPM[-{1-50}]-{1-4,11-14}-{1-4}-{1-4}

PPM[-{1-50}]-{1-6,12-17}-{1-4}

PPM[-{1-50}]-{1-6,12-17}-{1-8}

PWR-ALL

PWR[-{1-50}]-ALL

PWR[-{1-50}]-{A,B}

SLOT-ALL

SLOT[-{1-50}]-ALL

SLOT[-{1-50}]-{1-14}

SLOT[-{1-50}]-{1-17}

SLOT[-{1-50}]-{1-2}

SLOT[-{1-50}]-{1-4,11-14}

SLOT[-{1-50}]-{1-6,12-17}

SLOT[-{1-50}]-{1-8}

VCM

VCM-{1-6,12-17}-{0-1}-ALL

VCM-{1-6,12-17}-{0-1}-{1-256}

VCM-{1-6,12-17}-{1-4}-ALL

VCM-{1-6,12-17}-{1-4}-{1-256}

FACILITY

E1-{2}-{1-21}

E3-{2}-{1-3}

FAC-{1-4,11-14}-ALL

FAC-{1-4,11-14}-{1-16}

FAC-{1-4,11-14}-{1-4}

FAC-{1-4,11-14}-{1-4}-{1-4}-{1}

FAC-{1-4,14-17}-{1-8}

FAC-{1-4}-1

FAC-{1-4}-{1-4}

FAC-{1-6,12-17}-1

FAC-{1-6,12-17}-ALL

FAC-{1-6,12-17}-{0-11}

FAC-{1-6,12-17}-{0-1}

FAC-{1-6,12-17}-{1-50,14,16,18,20,22,24,
26,28,30,32,34,36}

FAC-{5,6,12,13}-{1}

FAC-{5-6}-{1-28}

FAC-{5-6}-{1-3}

FAC-{8,10}-{1}

FSTE-{1,2,5,6}-{0-7}

FSTE-{1,2,5,6}-{1-8}

FSTE-{1}-{0-7}

FSTE-{1}-{1-8}

STM1-{2}-{1-2}-{1}

STM1-{3,4}-{1-2}-{1}

STM4-{2}-{1-2}-{1}

STM4-{3,4}-{1-2}-{1}

STM16-{3,4}-{1-2}-{1}

VFAC-{1,2,5,6}-{0-1}

VFAC-{1,2,5,6}-{1-8}

FACILITY (cont.)

FAC-{1-6,12-17}-{1-50,14,16,18,20,22,24}

FAC-{1-6,12-17}-{1-50}

FAC-{1-6,12-17}-{1-4}

FAC-{1-6,12-17}-{1-6}

FAC-{1-6,12-17}-{1}

FAC-{1-6}-ALL

VFAC-{1-4,11-14}-{1-4}-{1-4}-1

VFAC-{1-6,12-17}-{0-1}

VFAC-{1-6,12-17}-{1,2}

VFAC-{1-6,12-17}-{1,2}-{1,8}

VFAC-{1}-{0-1}

VFAC-{1}-{1-8}

VC

VC11-{1-4,14-17}-{1-50}-1-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-1-{1-7}-{1-2}

VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}

VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-4}

VC12-{1-4,14-17}-{1-50}-1-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-1-{1-7}-{1-2}

VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}

VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}

VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC3-{1-14,14-17}-{1-50}-1-{1-3}

VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}

VC3-{1-4,14-17}-{1-8}-1-{1-3}

VC3-{1-6,12-17}-1-{1-16}-{1-3}

VC3-{1-6,12-17}-1-{1-4}-{1-3}

VC3-{1-6,12-17}-{1-4}-1-{1-3}

VC3-{1-6,12-17}-{1-4}-{1-3}

VC4-{1-4,11-14}-{1-16}-1

VC4-{1-4,11-14}-{1-16}-{1,5,9,13}

VC4-{1-4,11-14}-{1-16}-{1,9}

VC4-{1-4,11-14}-{1-4}-1

VC4-{1-4,11-14}-{1-4}-{1,17,33,49}

VC4-{1-4,11-14}-{1-4}-{1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61}

VC (continued)

VC4-{1-4,11-14}-{1-4}-{1,9,17,25,33,41,49,57}

VC4-{1-4,11-14}-{1-4}-{1-64}

VC4-{1-4,14-17}-1

VC4-{1-4,14-17}-1-1

VC4-{1-4,14-17}-{1-50}-1

VC4-{1-4,14-17}-{1-4}-1

VC4-{1-4,14-17}-{1-4}-{1-2}

VC4-{1-4,14-17}-{1-4}-{1-3}

VC4-{1-4,14-17}-{1-4}-{1-4}

VC4-{1-4,14-17}-{1-8}-1

VC4-{1-6,12-17}-1

VC4-{1-6,12-17}-1-1

VC4-{1-6,12-17}-1-{1,2,3,5,6,7,9,10,11,13,14,15}

VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}

VC4-{1-6,12-17}-1-{1,5,9,13}

VC4-{1-6,12-17}-1-{1-16}

VC4-{1-6,12-17}-1-{1-2}

VC4-{1-6,12-17}-1-{1-3}

VC4-{1-6,12-17}-1-{1-4}

VC4-{1-6,12-17}-1-{1-9}

VC4-{1-6,12-17}-{1-4}

VC4-{1-6,12-17}-{1-4}-1


27.12  ENV

Table 27-12 lists the environmental (ENV) AIDs for the AIC-I cards and their descriptions.

Table 27-12 ENV 

Pattern
Description

ALL

The ALL AID applies to retrieve-only commands: RTRV-ALM-ENV, RTRV-COND-ENV, RTRV-ATTR-CONT, and RTRV-ATTR-ENV.

ENV-IN-ALL

Environmental AID for ALL environmental alarms.

ENV-IN[-{1-50}]-ALL

Environmental AID for ALL multishelf environmental alarms.

ENV-IN[-{1-50}]-{1-4}

Environmental AID for the AIC-I card. "IN" is used for environmental alarms.

ENV-IN[-{1-50}]-{1-20}

Environmental AID for the AIC-I card. "IN" is used for environmental alarms.

ENV-IN[-{1-50}]-{1-32}

Environmental AID for AIC-I card extensions. "IN" is used for environmental alarms.

ENV-IN[-{1-50}]-{1-3}

Environmental AID for the AIC-I card. "IN" is used for environmental alarms.

ENV-IN[-{1-50}]-{1-6}

Environmental AID. "IN" is used for environmental alarms.

ENV-OUT-ALL

Environmental AID for AIC-I cards. "OUT" is used for environmental controls.

ENV-OUT[-{1-50}]-ALL

Environmental AID for AIC-I cards. "OUT" is used for environmental controls.

ENV-OUT[-{1-50}]-{1-4}

Environmental AID for AIC-I cards. "OUT" is used for environmental controls.

ENV-OUT[-{1-50}]-{1-16}

Environmental AID for AIC-I card extensions. "OUT" is used for environmental controls.

ENV-OUT[-{1-50}]-{1-2}

Environmental AID for AIC-I cards. "OUT" is used for environmental controls.

ENV-{IN,OUT}[-{1-50}]-{1-16}

ENV-IN[1-16} is used for the environmental alarm AID. ENV-OUT-{1-16} is used for the external control AID.


27.13  EQPT

Table 27-13 lists the equipment (EQPT) AIDs for the AIC-I cards and their descriptions. EQPT AIDs are used to access specific cards.

AID for CXP port on 100G-LC-C and 10x10G-LC: APPM-[SLOT]-[PPM]-[PORT]

Table 27-13 EQPT 

Pattern
Description

AIP-[-{1-50}]

The AID for the alarm interface panel (AIP). It is used for RTRV-INV output only.

AIP-ALL

The AID for all of the AIPs in any shelf of the node. It is used for RTRV-INV output only.

ALL

Only used for RTRV-INV, RTRV-EQPT, RTRV-ALM-EQPT, and RTRV-COND-EQPT commands. RTRV-INV returns all the inventory information for the NE. The NCS includes the multiservice cards, common control cards, and the AIP, BP, and FAN. RTRV-ALM-EQPT and RTRV-COND-EQPT with the ALL AID return EQPT and PWR-A and PWR-B type of alarms and conditions.

BIC-ALL

AIDs for the backplane interface connectors (BICs): BIC-A and BIC-B. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

BIC-[-{1-50}]-ALL

AIDs for the BICs: BIC-A and BIC-B of a single shelf in a multishelf node. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

BIC[-{1-50}]-{A,B}

AIDs for the BICs. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

BP[-{1-50}]

The AID for the backplane. It is used for RTRV-INV output only.

BP-ALL

The AID for all of the backplanes in any shelf on the multishelf node. It is used for RTRV-INV output only.

FAN[-{1-50}]

The AID for the fan tray. It is used for RTRV-INV output only.

FAN-ALL

The AID for all of the fan tray in all the shelves of a multishelf node. It is used for RTRV-INV output only.

PPM-{1-6,12-17}-1

PPM for the OC192-XFP card. Format is PPM-[SLOT]-[PPM].

PPM-{1-6,12-17}-{1-4}

Pluggable Port Module for MRC-4. Format is PPM-[SLOT]-[PPM]. It is not applied on CHG-EQPT, and RMV/RST/ED-EQPT commands.

PPM-{1-6,12-17}-{1-50}

Pluggable Port Module for MRC-12 card. Format is PPM-[SLOT]-[PPM]. It is not applied on CHG-EQPT, and RMV/RST/ED-EQPT commands.

PPM[-{1-50}]-{1-6,12-17}-
{1-4}

PPM AID for NCS MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_10E cards. Format of AID is PPM-[SLOT]-[PPM].

PPM[-{1-50}]-{1-6,12-17}-
{1-8}

PPM AID for the MXP_MR_2.5G and MXPP_MR_2.5G cards. Format of AID is PPM-[SLOT]-[PPM].

PUNIT-ALL

The whole NE Passive patch panel equipment AIDs. These AIDs are applicable to EQPT commands like ENT/DLT/RTRV/ED-EQPT commands.

PUNIT-{1-96}

Individual equipment AID of the Passive patch panel units where format is PUNIT-[id]. These AIDs are applicable to EQPT commands like ENT/DLT/RTRV/ED-EQPT commands.

PWR-ALL

AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

PWR[-{1-50}]-{A,B}

AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

PWR[-{1-50}]-ALL

AIDs for all of the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.

SLOT-ALL

All of the NE equipment AIDs.

SLOT[-{1-50}]-{1-17}

EQPT AID where the format is SLOT-[SLOT].

SLOT[-{1-50}]-{1-6,12-17}

Individual equipment AID of the multiservice card units or slots where the format is SLOT-[SLOT].

SPPM[-{36-55}]-{1-44}

PPM for the CPT 50 panel GIGE ports card. The format is SPPM-[PTSA]-[PPM].

SFOPPM[-{36-55}]-{45-48}

PPM for the CPT 50 panel 10GIGE ports card. The format is SFOPPM-[PTSA]-[PPM].

PTSYS[-{1}]-ALL

PT System AID for the CPT system. The format is PTSYS-{PTSYSID}.

FOG[-{1}]-{36-55}-ALL

Fan-Out-Group AID for connecting the CPT 50 panel to fabric and line cards. The format is FOG-{PTSYSID}-{FOGID}.


27.14  ETH

Ethernet (ETH) AIDs are used to access the ethernet port. Table 27-8 lists the ETH AIDs and their descriptions.

Table 27-14 ETH

Pattern
Description

ETH-{1,2,5,6}-{1-6}

Format is ETH-slot-port. Port numbering is 1-based.

ETH[-{1-50}]-{1-6,12-17}-{1-22}-{1}

Ethernet AID for ethernet port on GE_XP and 10GE_XP cards. The format is ETH-[SHELF]-[SLOT]-[PPM]-[PORT.

ETH[-{1-50}]-{1-6,12-17}-{1-22}-{1}-{1-4096}

Ethernet CEPID AID for ethernet port CEP on GE_XP and 10GE_XP cards. The format is ETH-[SHELF]-[SLOT]-[PPM]-[PORT]-[CEPID], where [CEPID] is the connection end point identifier, that identifies a single 1 Gbit/sec circuit inside an ethernet port.


27.15  FACILITY

Facilities AIDs are used to access specific ports. Table 27-15 lists the FACILITY AIDs and their descriptions. The FACILITY AID formats are as follows:

Format for DS3i-N-12 electrical facilities: FAC-[SLOT]-[PORT]

Format for POS ports: VFAC-[SLOT]-[PORT]

Format for POS port with PIM and PPM: VFAC-[SLOT]-[PIM]-[PPM]-[PORT]

Format for 100G-LC-C, 10x10G-LC, and CFP-LC cards: VLINE-[SLOT]-[PPM]-[PORT]-[SUBLANE-NO] Sublane Aid for all sublanes

Format for CXP port on 100G-LC-C card: AGGR-[SLOT]-[APPM]-[PORT].

Format for SFP+ ports on for 10x10G-LC and CFP-LC cards: VFAC-[SLOT]-[PPM]-[PORT]

Table 27-15 FACILITY 

Pattern
Description

ALL

The ALL AID is applicable for retrieve-only commands (RTRV-xx type of commands), for example: RTRV-STM16 with an ALL AID returns all STM16 facilities on the node.

AGGR[-{1-50}]-{2-7}-{1}-{1}

Facility AID for CXP port on 100G-LC-C card.

FAC[-{1-50}]-{1-4,14-17}-{1-8}

Facilities for an STM1 card where the format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{1-6,12-17}-1

Facility AID for the one client (CLNT) port on a TXP_MR_10G, TXP_MR_2.5G, TXP_MR_2.5G, or TXPP_MR_2.5G card where the format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{1-6,12-17}-ALL

All the facilities of an input/output (I/O) unit or slot where the format is FAC-[SLOT]-[ALL].

FAC[-{1-50}]-{1-6,12-17}-{0-11}

Facilities for the Ethernet front-end ports on the ML100T-12 card. Ports are numbered starting with 0 (for the ML100T-12, the first port is FAC-SLOT-0, second port is FAC-SLOT-1, etc., and the last port is FAC-SLOT-1l; for the ML1000-2, the first port is FAC-SLOT-0 and second port is FAC-SLOT-1). The format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{1-6,12-17}-{0-1}

Facilities for the Ethernet back-end ports on the ML1000-2 card. Ports are 0-based, (for example, the first port is FAC-SLOT-0 and the second port is FAC-SLOT-1). The format is FAC-[SLOT]-[PORT].

FAC-{1-6,12-17}-{1-8}

Facility AID for the Ethernet front-end ports on the CE-100T-8 card The format is FAC-[SLOT]-[PORT].

FAC-{1-6,12-17}-{0-11}

Facility AID for the Ethernet front-end ports on the MS-ISC-100T The first port is FAC-SLOT-0, the second port is FAC-SLOT-1, and so on. The last port is FAC-SLOT-11. The format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{1-6,12-17}-{1-12,
14,16,18,20,22,24,26,28,30,32,34,
36}

Facility AIDs for the DS3i-N-12 VC416 backplane rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available.

FAC[-{1-50}]-{1-6,12-17}-{1-12,14,16,18,20,22,24}

Facility AIDs for DS3i-N-12 VC44 backplane rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available.

FAC[-{1-50}]-{1-6,12-17}-{1-4}

Facility AID for the four CLNT facilities on the MXP_2.5G_10G card. Facility AID for 4-Port G1000/FC_MR-4 card. Facility AID for creating and editing cross-connects (VC3, VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C) for the 4-Port G1000/FC_MR-4 card where format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{1-6,12-17}-{1-6}

Facilities for the DS3i-N-12 card where the format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{1-6,12-17}-{1}

Facility AID for the 1-Port STM4, STM16, and STM1 in OSC-CSM cards. Facility AID for the client ports on the MXP/TXP and TXP_MR_2.5G cards where format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{5,6,12,13}-{1}

Facility AID for the STM16/STM64 cards. The STM16/STM64 cards can only use Slot 5, Slot 6, Slot 12, and Slot 13 where format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{8,10}-{1}

Facility AID for the OSCM card where format is FAC-[SLOT]-[PORT].

FAC[-{1-50}]-{1-6,12-17}-1-1

Facility AID for the TXP_MR_2.5G, TXPP_MR_2.5G, TXP_MR_10E, TXP_MR_10EX and TXPP_MR_10EX cards in the format of:FAC-[shelf]-[slot]-[ppm]-[port].

VFAC[-{1-50}]-{1-6,12-17}-{0-1}

Facilities for the back-end packet-over-NCS (POS) ports on the ML-Series card. Port numbering is 0-based (first POS port is VFAC-SLOT-0, second POS port is VFAC-SLOT-1). VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C for the ML1000 and ML100T cards. Format is VFAC-[SLOT]-[PORT].

VFAC-{1-6,12-17}-{0-15}

Facilities for ML-MR-10 back-end packet-over-NCS (POS) ports in MLMR-AUTO Mode. ML-MR-10 has 16 POS Ports. POS Ports are 0-Based. Format is VFAC-[slot]-[port]

VFAC[-{1-50}]-{1-6,12-17}-{1,2}

GFP facilities on the MXP-MR-2.5G and MXPP-MR-2.5G cards.

VFAC[-{1-50}]-{1-6,12-17}-{1,2}
-{1,8}

GFP client facilities for MXP-MR-2.5G and MXPP-MR-2.5G cards

FAC[-{1-50}]-{1-4,14-17}-{1-4}

Facility AID for four Ether Ports on the CE1000 card.

VFAC[-{1-50}]-{1-4,14-17}-{1-4}

Facility AID for the back-end ports on the CE1000 card.

VFAC[-{1-50}]-{2-7}-{1-10}-{1}

Facility AID for SFP+ ports on 10x10G-LC and CFP ports on Fumaiolo cards.

VLINE[-{1-50}]-{2-7}-{1-2}-{1}-{1-12}

Facility AID for sublanes on 10x10G-LC card only.

SFAC[-{36-55}]-{1-44}-1

GIGE facilities on the CPT 50 panel. The format is SFAC-[PTSAID]-[PPM]-[PORT].

SFOFAC[-{36-55}]-{45-48}-1

10GIGE facilities on the CPT 50 panel. The format is SFOFAC-[PTSAID]-[PPM]-[PORT].


27.16  FPLINE

FPLINE AIDs are used on passive OTS ports of MD-48-EVEN/MD-48-ODD passive module. Table 27-16 lists the FPLINE AIDs and their descriptions. The FPLINE AID format is: FPLINE-ID-PORT-DIR-LABEL

Table 27-16 FPLINE

Pattern
Description

FPLINE-{1-126}-{1-48}-{RX-TX}

All the ADD/DROP ports of MD-48-EVEN/MD-48-ODD passive module where format is FPCHAN-[id]-[port]-[DIR}.

FPLINE-{1-126}-{1-20}-{RX-TX}

All the IN/OUT ports of MF-DEG-5 passive module where format is FPCHAN-[id]-[port]-[DIR}.

FPLINE-{1-126}-{1-32}-{RX-TX}

All the IN/OUT ports of MF-UPG-4 passive module where format is FPCHAN-[id]-[port]-[DIR}.

FPLINE-{1-126}-{1-8}-{RX-TX}

All the ports of MF-MPO-8LC passive module where format is FPCHAN-[id]-[port]-[DIR.

FPLINE-{1-126}-{1-8}-{RX-TX}

All the IN/OUT ports of MF-4x4-COFS passive module where format is FPCHAN-[id]-[port]-[DIR}.

FPLINE-{1-126}-{1-17}-{RX-TX}

All the IN/OUT ports of MF-16AD-CFS passive module where format is FPCHAN-[id]-[port]-[DIR}.


27.17  IPADDR

Table 27-17 lists the IP address (IPADDR) AIDs and their descriptions.

Table 27-17 IPADDR 

Pattern
Description

111.222.333.444

Standard 4-part IP address notation

ALL

ALL


27.18  LINE

The LINE AID is used to access the Optical Transport Section (OTS) layer of optical networking units. Applicable only to NCS AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O, and 32DMX-O cards. The format is LINE-[SLOT]-[PORT]-[DIRECTION]. Table 27-18 lists the LINE AIDs and their descriptions.

Table 27-18 LINE 

Values
Description

ALL

All of the OTSs of the NE. The ALL AID applies to retrieve-only commands.

LINE-{1-6,12-17}-{1-2}-ALL

All the lines in a OPT-PRE, OCS-CSM, AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, and AD-4C-xx.x cards.

LINE-{1-6,12-17}-{1-2}-{RX,TX}

The receive/transmit lines in a OPT-PRE, AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, and AD-4C-xx.x cards.

LINE-{1-6,12-17}-{1-3}-{RX,TX}

The receive/transmit lines in a OPT-BST cards.

LINE-{8,10}-{1}-ALL

All the lines in a OSCM cards.

LINE-{8,10}-{1}-{RX,TX}

The receive/transmit lines in OSCM car

LINE-[{1-50}-]{1-6,12-17}-{1}-
{RX,TX}

For booster cards, there is an input OTS for LINE(1) and an output OTS (amplified) for amplification stage COM(2), two OTS for input line COM(2) and output LINE(1), and 2 OTS for OSC(3) add and drop service channel.

LINE-[{1-50}-]{1-6,12-17}-{2}-
{RX,TX}

LINE-[{1-50}-]{1-6,12-17}-{3}-
{RX,TX}

LINE-[{1-50}-]{1-6,12-17}-{1-3}-ALL

LINE-[{1-50}-]{1-6,12-17}-{1}-
{RX,TX}

Preamplifier card with 2 stages of amplification; input OTS for LINE(1) and an output OTS (amplified) for amplification stage COM(2), two OTS for input line COM(2) and output LINE(1), and two OTS for OSC(3) add and drop service channel and output and an input OTS for the DCU(2).

LINE-[{1-50}-]{1-6,12-17}-{2}-
{RX,TX}

LINE-[{1-50}-]{1-6,12-17}-{3}-
{RX,TX}

LINE-[{1-50}-]{1-6,12-17}-{4}-
{RX,TX}

LINE-[{1-50}-]{1-6,12-17}-{1-4}-ALL

LINE-[{1-50}-]{1-6,12-17}-1-RX
For input OTS

For demultiplexer cards, there is an OTS for input line and up to 32 OCH for drop channel connectors. A demultiplexer is a unidirectional unit.

LINE-[{1-50}-]{1-6,12-17}-1-ALL

CHAN-[{1-50}-]{1-6,12-17}-{1-32}-TX for Drop OCH

CHAN-[{1-50}-]{1-6,12-17}-{1-32}-
ALL

LINE-[{1-50}-]{1-5,12-16}-{1}-
{RX,TX} (EXP)

Wavelength switch selector card has input and output OTS for signals coming from amplifier units COM(2), input and output OTS for signal continuing to next WSS unit in the node EXP(1), and an output PT(3) drop port for the signal continuing to 32DMX-L card. It also has 32 internal OCH pass-through channels (PT) and 32 external input channels (ADD). This unit is 2 slots wide.

LINE-[{1-50}-]{1-5,12-16}-{2}-
{RX,TX} (COM)

LINE-[{1-50}-]{1-5,12-16}-{3}-{TX} (DROP)

LINE-[{1-50}-]{1-5,12-16}-{1-3}-ALL

CHAN-[{1-50}-]{1-5,12-16}-{1-32}-
{RX} (ADD)

CHAN-[{1-50}-]{1-5,12-16}-{1-32}-
{PT} (PT)

CHAN-[{1-50}-]{1-5,12-16}-{1-32}-
ALL

LINE-[{1-50}-]{1-6,12-17}-{1}-
{RX,TX} (EXP)

Multiring/mesh unit has 6 OTS connectors: two are the input and output OTS for signal coming from amplifier units COM(1), the other four are for the split 50/50 signals continuing to AD, MUX/DMX, and WSS units. Because the incoming signal is split into two separate signals, there are two sets of input and output EXP ports (2 and 3).

LINE-[{1-50}-]{1-6,12-17}-{2}-
{RX,TX} (COM)

LINE-[{1-50}-]{1-6,12-17}-{3}-
{RX,TX} (EXP to other ring)

LINE-[{1-50}-]{1-6,12-17}-{1-3}-ALL

PLINE-ALL

All the EXP/COMM/DC lines in all the Passive patch panel module where format is PLINE-ALL.

PLINE-{1-96}-ALL

All the EXP/COM/DC lines in a Passive patch panel module where format is PLINE-[id]-ALL.

PLINE-{1-96}-{1}-ALL

All the IN and OUT DC/COM lines in DCU,15216-MD-40-ODD/EVEN passive modules where format is PLINE-[id]-[port]-ALL

PLINE-{1-96}-{1-3}-ALL

All the IN and OUT COM lines in 15216-MD-ID-50 passive module where format is PLINE-[id]-[port]-ALL.

PLINE-{1-96}-{1-20}-ALL

All the IN COM and OUT EXP lines in PP-MESH-4 passive module where format is PLINE-[id]-[port]-ALL.

PLINE-{1-96}-{1-72}-ALL

All the IN COM and OUT EXP lines in PP-MESH-8 passive module where format is PLINE-[id]-[port]-ALL.

PLINE-{1-96}-{1}-{RX-TX}

The Receive or Transmit DC/COM lines in DCU,15216-MD-40-ODD/EVEN passive modules where format is PLINE-[id]-[port]-[direction]

PLINE-{1-96}-{1-3}-{RX-TX}

The Recieve or Transmit COM line in a 15216-MD-ID-50 passive module where format is PLINE-[id]-[port]-[direction].

PLINE-{1-96}-{1,6,11,16}-RX

The Recieve COM lines in a PP-MESH-4 passive module where format is PLINE-[id]-[port]-[direction].

PLINE-{1-96}-{2-5,7-10,12-15,17-20}-TX

The Transmit EXP lines in a PP-MESH-4 passive module where format is PLINE-[id]-[port]-[direction].

PLINE-{1-96}-{1,10,19,28,37,46,55,64}-RX

The Recieve COM line in a PP-MESH-8, passive modules where format is PLINE-[id]-[port]-[direction].

PLINE-{1-96}-{2-9,11-18,20-27,29-36,38-45,47-54,56-63,65-72}-TX

The Transmit EXP line in a PP-MESH-8, passive modules where format is PLINE-[id]-[port]-[direction].

PLINE-{1-96}-{1}-{RX-TX}

The Recieve or Transmit COM line in a 15216-FLD-xx-x, passive modules where format is PLINE-[id]-[port]-[direction].

PLINE-{1-96}-{2}-{RX-TX}

The Recieve or Transmit EXP line in a 15216-FLD-xx-x, passive modules where format is PLINE-[id]-[port]-[direction].


27.19  LINEWL

The line wavelength (LINEWL) AID identifies a wavelength channel included in any of the lower layer OTS facilities. Table 27-20 lists the LINEWL AIDs and their descriptions.

Table 1:

Values
Description

LINEWL[-{1-50}]-{1-6,8,10,12-17}-ALL

All the Optical Channels representing single wavelength inside OTS facility of a card configured in specified slot. The format is LINE-[SHELF]-[SLOT]-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-ALL

The Optical Channel representing single wavelength inside OTS facility in a 32-DMX-O, 32-DMX, 32-DMX-L, 32-MUX-O, 40-DMX-C, 40-MUX-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.

LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-<wlen>

The Optical Channel representing single wavelength inside OTS facility in a 32-DMX-O, 32-DMX, 32-DMX-L, 32-MUX-O, 40-DMX-C, 40-MUX-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].

LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-ALL

The Optical Channel representing single wavelength inside OTS facility in a 32-WSS, 40-WSS-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.

LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS facility in a 32-WSS, 40-WSS-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL

All the Optical Channel representing single wavelength inside OTS facility in a AD-1B, AD-4B, AD-1C, AD-2C, AD-4C units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS facility in a AD-1B, AD-4B, AD-1C, AD-2C, AD-4C units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN]

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL

All the Optical Channel representing single wavelength inside OTS (COM=1, DC=2) facility in an OPT-PRE unit. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS (COM=1, DC=2) facility in a OPT-PRE units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-<WLEN>

LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-ALL

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C, and OPT-AMP-23-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.

LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C, OPT-AMP-23-C, and OPT-AMP-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].

LINEWL[-{1-50}]-{1-6,12-17}-{1,3,4}-{RX,TX}-ALL

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3, DC=4) facility in a OPT-AMP-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.

LINEWL[-{1-50}]-{1-6,12-17}-{1,3,4}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3, DC=4) facility in a OPT-AMP-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].

LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-ALL

All the Optical Channel representing single wavelength inside OTS (COM) facility in a OPT-PRE units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL

LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS (COM) facility in a OPT-PRE units.The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN]

LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-ALL

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C and OPT-AMP-23-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.

LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C and OPT-AMP-23-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=2) facility in a OSC-CSM cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.

LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside OTS (COM=1, LINE=2) facility in a OSC-CSM cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].

LINEWL-
[{1-50}]-{1-5,12-16}-{1-8}-{RX}-<WLEN>

The Optical Channel representing single wavelength inside EXP lines from all the other WXC cards in a 40-WX-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].

LINEWL-
[{1-50}]-{1-5,12-16}-{9}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside ADD/DROP line to/from MUX/DMX/WSS cards in a 40-WXC-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].

LINEWL-
[{1-50}]-{1-5,12-16}-{10}-{TX}-<WLEN>

The Optical Channel representing single wavelength inside EXP line in a 40-WXC-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].

LINEWL-
[{1-50}]-{1-5,12-16}-{11}-{RX,TX}-<WLEN>

The Optical Channel representing single wavelength inside COM line in a 40-WXC-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].

LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-<LABEL>

The Optical Channel representing OCHTERM interface in a OPT-EDRA/OPT-EDFA/16-WXC-FS units.The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-[LABEL].


27.20  LNKTERM

Link Termination (LNKTERM) AIDs are used to access the termination points of a provisionable patchcord. Table 27-19 lists the LINKTERM AIDs and their descriptions.

Table 27-19 LNKTERM 

Pattern
Description

ALL

Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands.

LNKTERM-ALL

Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands.

LNKTERM-{1-65535}

Indicates a single provisionable patchcord termination point on a node.


27.21  MSSPR

Multiplex section-shared protection ring (MSSPR) AIDs are used to access the MS-SPRing of the NE. Table 27-20 lists the MSSPR AIDs and their descriptions.

Table 27-20 MSSPR 

Pattern
Description

ALL

ALL AID for all MS-SPRings in the NE. The ALL AID is applicable for retrieve-only commands like RTRV-MSSPR, RTRV-ALM-MSSPR, and RTRV-COND-MSSPR.

MSSPR-RINGID

MS-SPRing AID is keyword MS-SPRing followed by RINGID. RINGID is a string of up to 6 characters; valid characters are [A-Z,0-9] (case insensitive).


27.22  OPM

Optical power monitoring (OPM) AIDs represent the single wavelength inside an optical power monitoring object. Table 27-21 lists the OPM AIDs and their descriptions.

Table 27-21 OPM

Values
Description

ALL

The first ID represents the shelf, the second ID represents the slot, and the last ID is the wavelength, represented in the form of 15xx.yy nanometers. The last index of the wavelength is the value of the wavelength as described in OPTICAL_WLEN.

OPM[-{1-50}]-{1-5,12-16}-ALL

OPM[-{1-50}]-{1-5,12-16}-<WLEN>


27.23  OSC

Optical service channel (OSC) AIDs are used to access the OSC of the NE. Table 27-22 lists the OSC AIDs and their descriptions.

Table 27-22 OSC 

Values
Description

ALL

All of the OSCs of the NE. The ALL AID applies to the retrieve-only commands.

OSC-RINGID

RINGID is a string of up to six characters, valid characters are [A-Z,0-9] (case insensitive).


27.24  PRSLOT

Valid protection slots for the electrical cards. Format is SLOT-[SLOT]. Table 27-23 lists the PRSLPT AIDs and their descriptions.

Table 27-23 PRSLOT 

Pattern
Description

NULL

Indicates there is no protection group. Used when trying to delete a protection group.

SLOT-1

Slot 1 of an NE.

SLOT-2

Slot 2 of an NE.

SLOT-3

Slot 3 of an NE.

SLOT-5

Slot 5 of an NE.

SLOT-6

Slot 6 of an NE.

SLOT-13

Slot 13 slot of an NE.

SLOT-15

Slot 15 slot of an NE.

SLOT-17

Slot 17 slot of an NE.


27.25  RFILE

Table 27-24 lists the file transfer type (RFILE) AIDs and their descriptions.

Table 27-24 RFILE

Pattern
Description

RFILE-DB

Transferring the provisioning database.

RFILE-LOG

Transferring a log file.

RFILE-PKG

Transferring a software package.

RFILE-COMPDB

Transferring the provisioning and system database.


27.26  SHELF

The SHELF AID identifies a shelf within a node. SHELF is applicable only to nodes that are set to MULTISHELF or MULTISHELFETH mode. Table 27-25 lists the SHELF AIDs and their descriptions.

Table 27-25 SHELF 

Pattern
Description

SHELF-ALL

All of the shelves in the node.

SHELF-{1-50}

A specific shelf in the node (shelf 1 through 30).


27.27  SYN

Table 27-26 lists the synchronization (SYN) AIDs and their descriptions.

Table 27-26 SYN 

Pattern
Description

SYNC[-{1-50}]-ALL

ALL synchronization AID (values 1 to 8 is the shelf ID).

SYNC[-{1-50}]-NE

NE synchronization AID (values 1 to 8 is the shelf ID).

SYNC[-{1-50}]-{BITS1,BITS2}

BITS synchronization AID (values 1 to 8 is the shelf ID).


27.28  SYN_SRC

Table 27-27 lists the synchronization source (SYN_SRC) AIDs and their descriptions.

Table 27-27 SYN_SRC 

Pattern
Description

BITS-1

Synchronization source is BITS-1. Format is BITS-[PORT].

BITS-2

Synchronization source is BITS-2. Format is BITS-[PORT].

FAC-{1-4,11-14}-{1-4}

Synchronization source is the 4-port STM64. Format is FAC-[SLOT]-[PORT].

FAC-{1-6,12-17}-{1-4}

Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT].

FAC-{1-6,12-17}-{1}

Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT].

FAC-{5,6,12,13}-{1}

Synchronization source is the optical card (STM16 and STM 64) facility. Format is FAC-[SLOT]-[PORT].

INTERNAL

Set the SYN_SRC to be the system default value. This value is only applied for the SYNC-NE AID on the ED-SYNCN command.

NONE

Set the SYNC_SRC value to the default value for BITS-OUT. This value only applies to the BITS-1 and BITS-2 AID of the ED-SYNCN command.

SYNC-NE

SYNC-NE source. It is only used in the alarm report or alarm retrieve commands.


27.29  SYNC_REF

Table 27-28 lists the synchronization reference (SYNC_REF) AIDs and their descriptions. The Facility AID formats for line timing are as follows:

Format for optical facilities without PPM: FAC-[SLOT]-[PORT]

Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]

Table 27-28 SYNC_REF 

Pattern
Description

ALL

Equivalent to a combination of SYNC-ALL, BITS-1, and BITS-2. This AID is valid only for the commands RTRV-SYNCN, RTRV-ALM-SYNCN, and RTRV-COND-SYNCN.

SYNC-ALL

All synchronization references.

SYNC-{1-50}-NE

NE synchronization AID.

SYNC-{1-50}-{BITS1,BITS2}

BITS1 and BITS2 synchronization AIDs.


27.30  SYNCSW

Table 27-29 lists the synchronization switch (SYNCSW) AIDs and their descriptions.

Table 27-29 SYNCSW 

Pattern
Description

INT

Internal clock. The "INT" value of the SYNCSW is only applied for the SYNC-NE AID on the OPR-SYNCSW command.

PRI

Primary timing reference.

SEC

Secondary timing reference.


27.31  UDC

Table 27-30 lists the user data channel (UDC) AIDs and their descriptions F-UDC and DCC-UDC channels on the AIC-I card.

Table 27-30 UDC 

Pattern
Description

ALL

ALL AID is applicable to retrieve-only commands, for example: RTRV-ALM-UDCF, RTRV-COND-UDCF, RTRV-ALM-UDCDCC, and RTRV-COND-UDCDCC. It corresponds to a superset of F-UDC and DCC-UDC AIDs.

UDC-{F,DCC}-{A,B}

F-UDC and DCC-UDC AIDs for A and B channels.


27.32  VC

Table 27-31 lists the virtual channel (VC) AIDs and their descriptions for the NCS frame-level AID set. The VC4 AID formats are as follows:

For Optical Facilities: VC4-[SLOT]-[PORT]-[VC4]

For Electrical Facilities: VC4-[SLOT]-[VC4]

The VC3 AID formats are as follows:

For Optical Facilities: VC3-[SLOT]-[PORT]-[VC4]-[VC3]

For Electrical Facilities: VC3-[SLOT]-[VC4]-[VC3]

The VC12 AID formats are as follows:

For Optical Facilities: VC12-[SLOT]-[PORT]-[VC4]-[VC3]-[TUG2]-[VC12]

For Electrical Facilities: VC12-[SLOT]-[VC4]-[VC3]-[TUG2]-[VC12]

The VC11 AID formats are as follows:

For Optical Facilities: VC11-[SLOT]-[PORT]-[VC4]-[VC3]-[TUG2]-[VC11]

For Electrical Facilities: VC11-[SLOT]-[VC4]-[VC3]-[TUG2]-[VC11]

Table 27-31 VC 

Pattern
Description

VC11-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-4}

VC11 for the STM1E-12 card

VC11-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}

VC11 for STM4-4

VC11-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-4}

VC11 for STM1-8 card

VC11-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-4}

VC11 for STM-16 card

VC11-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-4}

VC11 for STM-4 card

VC11-{1-6,12-17}-{1-14}-1-11{1-7}-{1-2}

VC11 for the E1 card

VC11-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC11 for the STM-1 card

VC12-{1-4,14-17}-{1-12}-1-{1-3}-{1-7}-{1-3}

VC12 for the STM1E-12 card

VC12-{1-4,14-17}-{1-4}-{1-4}-{1-3}-{1-7}-{1-3}

VC12 for STM4-4 card

VC12-{1-4,14-17}-{1-8}-1-{1-3}-{1-7}-{1-3}

VC12 for STM1-8 card

VC12-{1-6,12-17}-1-1-{1-7}-{1-2}

VC12 AIDs for the E1 card

VC12-{1-6,12-17}-1-{1-16}-{1-3}-{1-7}-{1-3}

VC12 for STM-16 card

VC12-{1-6,12-17}-1-{1-2}-{1-7}-{1-3}

VC12 for E1-42 card

VC12-{1-6,12-17}-1-{1-4}-{1-3}-{1-7}-{1-3}

VC12 for STM-4 card

VC12-{1-6,12-17}-{1-4}-1-{1-3}-{1-7}-{1-3}

VC12 for STM-1 card

VC3-{1-14,14-17}-{1-12}-1-{1-3}

VC3 for the STM1E-12 card

VC3-{1-4,14-17}-{1-4}-{1-4}-{1-3}

VC3 for the STM4-4 card

VC3-{1-4,14-17}-{1-8}-1-{1-3}

VC3 for the STM1-8 card

VC3-{1-6,12-17}-1-{1-16}-{1-3}

VC3 for the STM-16 card

VC3-{1-6,12-17}-1-{1-4}-{1-3}

VC3 for the STM-4 card

VC3-{1-6,12-17}-{1-4}-1-{1-3}

VC3 for the STM-1 card

VC3-{1-6,12-17}-{1-4}-{1-3}

VC3 AID for DS3i-N-12 and E3 card

VC4-{1-4,14-17}-1

VC4 for E1-42 card

VC4-{1-4,14-17}-1-1

VC4 for STM1-8 card

VC4-{1-4,14-17}-{1-12}-1

VC4 for the STM1E-12 card

VC4-{1-4,14-17}-{1-4}-1

VC4 for the STM4 card and VC4-4c for the STM4-4 card

VC4-{1-4,14-17}-{1-4}-{1-2}

VC4-3c for the STM4-4 card

VC4-{1-4,14-17}-{1-4}-{1-3}

VC4-2c for the STM4-4 card

VC4-{1-4,14-17}-{1-4}-{1-4}

VC4 for the STM4-4 card

VC4-{1-4,14-17}-{1-8}-1

VC4 for the STM1-8 card

VC4-{1-6,12-17}-1

VC4 for E1 card

VC4-{1-6,12-17}-1-1

VC4-4c for the STM-4 card. VC4-16c for the STM-16 card

VC4-{1-6,12-17}-1-{1,2,3,5,6,7,9,10,11,13,14,15}

VC4-2c for the STM-16 card

VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}

VC4-3c for the STM-16

VC4-{1-6,12-17}-1-{1,5,9,13}

VC4-4c for the STM-16 card

VC4-{1-6,12-17}-1-{1-16}

VC4 for the STM-16 card

VC4-{1-6,12-17}-1-{1-2}

VC4-3c for the STM-4 card

VC4-{1-6,12-17}-1-{1-3}

VC4-2c for the STM-4 card

VC4-{1-6,12-17}-1-{1-4}

VC4 for the STM-4 card

VC4-{1-6,12-17}-1-{1-9}

VC4-8c for the STM-16 card (454)

VC4-{1-6,12-17}-{1-4}

VC4 for DS3i-N-12, E3, G1000 cards

VC4-{1-6,12-17}-{1-4}-1

VC4 for STM-1 card


27.33  WDMANS

The WDMANS AID is used to access the automatic optical node setup (AONS) application of the NE. Table 27-32 lists the synchronization switch (SYNCSW) AIDs and their descriptions.

Table 27-32 WDMANS 

Pattern
Description

WDMSIDE-{UNKNOWN,A,B,C,D,E,F,G,H}

Automatic MSTP node setup identifier

WDMNODE

Automatic MSTP node setup identifier


27.34  WLEN

This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line), the wavelengths contained are all the available wavelengths in the node (currently 32). If the facility is of type OCH (CHAN), the wavelength is the one correspondent wavelength customized for that channel. Table 27-33 lists the WLEN AIDs and their descriptions.

Table 27-33 WLEN 

Pattern
Description

WLEN-{E,W}-{ADD,DROP,EXP}-{1530.33,1531.12,1531.90,1532.68,1534.25,
1535.04,1535.82,1536.61,1538.19,1538.98,1539.77,1540.56,1542.14,1542.94,1543.73,1544.53,1546.12,1546.92,1547.72,1548.51,1550.12,1550.92,1551.72,1552.52,
1554.13,1554.94,1555.75,1556.55,1558.17,1558.98,1559.79,1560.61,1577.44,1577.86,1578.27,1578.69,1579.10,1579.52,1579.93,1580.35,1580.77,1581.18,1581.60,1582.02,1582.44,1582.85,1583.27,1583.69,1584.11,1584.53,1584.95,1585.36,1585.78,1586.20,1586.62,1587.04,1587.46,1587.88,1588.30,1588.73,1589.15,1589.57,1589.99,1590.41,1590.83,1591.26,1591.68,1592.10,1592.52,1592.95,1593.37,1593.79}

Wavelength identifier


27.35  CTC Port Numbers and TL1 Aids

Table 27-34 CTC Port Numbers and TL1 Aids

Equipment
CTC Port Name
CTC Port Number
TL1 Aid

OPT-RAMP-C

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

DC-RX

7

LINE-shelf-slot-4-RX

DC-TX

8

LINE-shelf-slot-4-TX

RAMAN-RX

9

LINE-shelf-slot-5-RX

RAMAN-TX

10

LINE-shelf-slot-5-TX

OPT-AMP-17C

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

OPT-AMP-C

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

DC-RX

7

LINE-shelf-slot-4-RX

DC-TX

8

LINE-shelf-slot-4-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

OSC-CSM

COM-RX

2

LINE-shelf-slot-1-RX

COM-TX

3

LINE-shelf-slot-1-TX

LINE-RX

4

LINE-shelf-slot-2-RX

LINE-TX

5

LINE-shelf-slot-2-TX

OSC-RX

6

LINE-shelf-slot-3-RX

OSC-TX

7

LINE-shelf-slot-3-TX

OC3

1

FAC-shelf-slot-1

40 WXC

EXP-i-RX

1..8

LINE-shelf-slot-i-RX (i=1..8)

EXP-TX

11

LINE-shelf-slot-10-TX

ADD-RX

9

LINE-shelf-slot-9-RX

DROP-TX

10

LINE-shelf-slot-9-TX

COM-RX

12

LINE-shelf-slot-11-RX

COM-TX

13

LINE-shelf-slot-11-TX

80-WXC-C

EAD-i-R/T

1..8

LINE-shelf-slot-i (i=1..8)

ADD R/T

9

LINE-shelf-slot-9

COM R/T

10

LINE-shelf-slot-10

DROP-TX

11

LINE-shelf-slot-11-TX

COM-RX

13

LINE-shelf-slot-13-RX

EXP-TX

12

LINE-shelf-slot-12-TX

32 DMX

CHAN TX

1-32

CHAN-shelf-slot-i-TX (i=1..32)

COM-RX

33

LINE-shelf-slot-1-RX

OPT-PRE

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

DC-RX

3

LINE-shelf-slot-2-RX

DC-TX

4

LINE-shelf-slot-2-TX

40 DMX

CHAN TX

1 - 40

CHAN-shelf-slot-i-TX (i=1..40)

COM RX

41

LINE-shelf-slot-1-RX

4 MD

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

CHAN-RX

3

CHAN-shelf-slot-2-RX

CHAN-TX

4

CHAN-shelf-slot-2-TX

CHAN-RX

5

CHAN-shelf-slot-3-RX

CHAN-TX

6

CHAN-shelf-slot-3-TX

CHAN-RX

7

CHAN-shelf-slot-4-RX

CHAN-TX

8

CHAN-shelf-slot-4-TX

COM-RX

9

LINE-shelf-slot-1-RX

COM-TX

10

LINE-shelf-slot-1-TX

40 MUX

CHAN-RX

1-40

CHAN-shelf-slot-i-RX (i=1..40)

COM-TX

41

LINE-shelf-slot-1-TX

32 DMX L

CHAN TX

1 - 32

CHAN-shelf-slot-i-TX (i=1..32)

COM RX

33

LINE-shelf-slot-1-RX

32 WSS L

ADD-RX

1-32

CHAN-shelf-slot-i-RX (i=1..32)

PT

33-64

CHAN-shelf-slot-i-PT (i=1..32)

DROP-TX

69

LINE-shelf-slot-3-TX

EXP-RX

66

LINE-shelf-slot-2-RX

EXP-TX

65

LINE-shelf-slot-2-TX

COM-RX

68

LINE-shelf-slot-1-RX

COM-TX

67

LINE-shelf-slot-1-TX

OPT-BST

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

OPT-BST E

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

OPT-AMP L

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-1-TX

DC-RX

7

LINE-shelf-slot-4-RX

DC-TX

8

LINE-shelf-slot-4-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-3-RX

LINE-TX

6

LINE-shelf-slot-3-TX

OPT-BST L

COM-RX

1

LINE-shelf-slot-1-RX

COM-TX

2

LINE-shelf-slot-2-TX

OSC-RX

3

LINE-shelf-slot-1-RX

OSC-TX

4

LINE-shelf-slot-2-TX

LINE-RX

5

LINE-shelf-slot-1-RX

LINE-TX

6

LINE-shelf-slot-2-TX

MMU

EXPA-RX

5

LINE-shelf-slot-3-RX

EXPA-TX

6

LINE-shelf-slot-3-TX

EXP-RX

1

LINE-shelf-slot-1-RX

EXP-TX

2

LINE-shelf-slot-1-TX

COM-RX

3

LINE-shelf-slot-2-RX

COM-TX

4

LINE-shelf-slot-2-TX

PSM

W-RX

1

LINE-shelf-slot-1-RX

W-TX

2

LINE-shelf-slot-1-TX

P-RX

3

LINE-shelf-slot-2-RX

P-TX

4

LINE-shelf-slot-2-TX

COM-RX

5

LINE-shelf-slot-3-RX

COM-TX

6

LINE-shelf-slot-3-TX

AD 1B

BAND-RX

1

BAND-shelf-slot-1-RX

BAND-TX

2

BAND-shelf-slot-1-TX

EXP-RX

3

LINE-shelf-slot-1-RX

EXP-TX

4

LINE-shelf-slot-1-TX

COM-RX

5

LINE-shelf-slot-2-RX

COM-TX

6

LINE-shelf-slot-2-TX

AD 1C

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

EXP-RX

3

LINE-shelf-slot-1-RX

EXP-TX

4

LINE-shelf-slot-1-TX

COM-RX

5

LINE-shelf-slot-2-RX

COM-TX

6

LINE-shelf-slot-2-TX

AD 2C

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

CHAN-RX

3

CHAN-shelf-slot-2-RX

CHAN-TX

4

CHAN-shelf-slot-2-TX

EXP-RX

5

LINE-shelf-slot-1-RX

EXP-TX

6

LINE-shelf-slot-1-TX

COM-RX

7

LINE-shelf-slot-2-RX

COM-TX

8

LINE-shelf-slot-2-TX

AD 4C

CHAN-RX

1

CHAN-shelf-slot-1-RX

CHAN-TX

2

CHAN-shelf-slot-1-TX

CHAN-RX

3

CHAN-shelf-slot-2-RX

CHAN-TX

4

CHAN-shelf-slot-2-TX

CHAN-RX

5

CHAN-shelf-slot-3-RX

CHAN-TX

6

CHAN-shelf-slot-3-TX

CHAN-RX

7

CHAN-shelf-slot-4-RX

CHAN-TX

8

CHAN-shelf-slot-4-TX

EXP-RX

9

LINE-shelf-slot-1-RX

EXP-TX

10

LINE-shelf-slot-1-TX

COM-RX

11

LINE-shelf-slot-2-RX

COM-TX

12

LINE-shelf-slot-2-TX

32 WSS

ADD-RX

1-32

CHAN-shelf-slot-i-RX (i=1..32)

PT

33-64

CHAN-shelf-slot-i-PT (i=1..32)

DROP-TX

69

LINE-shelf-slot-3-TX

EXP-RX

66

LINE-shelf-slot-2-RX

RXP-TX

65

LINE-shelf-slot-2-TX

COM-RX

68

LINE-shelf-slot-1-RX

COM-TX

67

LINE-shelf-slot-1-TX

40 WSS CO

ADD-RX

1-40

CHAN-shelf-slot-i-RX (i=1..32)

PT

41-80

CHAN-shelf-slot-i-PT (i=1..32)

DROP-TX

85

LINE-shelf-slot-3-TX

EXP-RX

82

LINE-shelf-slot-2-RX

RXP-TX

81

LINE-shelf-slot-2-TX

COM-RX

84

LINE-shelf-slot-1-RX

COM-TX

83

LINE-shelf-slot-1-TX

32 DMXO

CHAN-TX

1-32

CHAN-shelf-slot-i-TX (i=1..32)

COM-RX

33

LINE-shelf-slot-1-RX

32 MUXO

CHAN RX

1-32

CHAN-shelf-slot-i-RX (i=1..32)

COM TX

33

LINE-shelf-slot-1-TX

SMR-1

EXP-RX

1

LINE-shelf-slot-1-RX

EXP-TX

2

LINE-shelf-slot-1-TX

DC-RX

3

LINE-shelf-slot-2-RX

DC-TX

4

LINE-shelf-slot-2-TX

OSC-RX

5

LINE-shelf-slot-3-RX

OSC-TX

6

LINE-shelf-slot-3-TX

ADD-RX

7

LINE-shelf-slot-4-RX

DROP-TX

8

LINE-shelf-slot-4-TX

LINE-RX

9

LINE-shelf-slot-5-RX

LINE_TX

10

LINE-shelf-slot-5-TX

SMR-2

DC-RX

1

LINE-shelf-slot-1-RX

DC-TX

2

LINE-shelf-slot-1-TX

OSC-RX

3

LINE-shelf-slot-2-RX

OSC-TX

4

LINE-shelf-slot-2-TX

ADD-RX

5

LINE-shelf-slot-3-RX

DROP-TX

6

LINE-shelf-slot-3-TX

LINE-RX

7

LINE-shelf-slot-4-RX

LINE_TX

8

LINE-shelf-slot-4-TX

EXP-TX-1

9

LINE-shelf-slot-5-TX

EXP-RX-2

10

LINE-shelf-slot-6-RX

EXP-RX-3

11

LINE-shelf-slot-7-RX

EXP-RX-4

12

LINE-shelf-slot-8-RX

10x10G-LC

CXP [port 11]

CXP 11-2...11or
11-2...11

VLINE-SL-1-1-i (i=2...11)

100G-LC-C

CXP [port 1]

CXP 1-2...11 or
1-2...11

VLINE-SL-1-1-i (i=2...11)

CFP-LC

CFP-1

CFP 1-1...10 or
1-1...10

VLINE-SL-1-1-i (i=1...10)

CFP-2

CFP 2-1...10 or
2-1...10

VLINE-SL-2-1-i (i=1...10)