This chapter describes the access identifiers (AIDs) of TL1 commands and autonomous messages for the Cisco NCS 2002 and Cisco NCS 2006.
The AID code directs an input command to its intended physical or data entity inside the network element (NE). Equipment modules and facilities are typical examples of entities addressed by the access code.
Table 27-3 lists the AidUnionId1 AIDs and patterns.
Table 27-3 AidUnionId1
AID
Patterns
MS-SPRing
ALL
MSSPR-RINGID
27.4 BAND
The BAND AID is used to access Optical Multiplex Section (OMS) layer of optical networking units. Table 27-4 lists the BAND AIDs and their descriptions.
AID for OCH interface of CXP port on 100G-LC-C card: ACHAN-[SLOT]-[PPM]-[PORT].
AID for fixed trunk on 100G-LC-C card: CHAN-[SLOT]-[PORT].
Table 27-4 BAND
Pattern
Description
ALL
All of the OMSs of the NE. The ALL AID is applicable for retrieve-only commands.
BAND[-{1-50}]-{1-6,12-17}-{1-4}-ALL
All the channels in a Band OADM (AD-1B-xx.x, AD-4B-xx.x) unit.
BAND[-{1-50}]-{1-6,12-17}-{1-4}-{RX,TX}
The Receive/Transmit channels in a Band OADM (AD-1B-xx.x, AD-4B-xx.x) unit.
BAND[-{1-50}]-{1-6,12-17}-{1}-ALL
All the channels in an Optical Multiplexer/Demultiplexer (4MD-xx.x) unit.
BAND[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}
The Receive/Transmit channels in an Optical Multiplexer/Demultiplexer (4MD-xx.x) unit.
27.5 BANDWL
Band wavelength. Identifies a wavelength channel included in any of the lower layer OMS facilities. Table 27-5 lists the BANDWL AIDs and their descriptions.
Table 27-5 BANDWL
Pattern
Description
BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-1530.33
Identifies an allocated wavelength channel included in any of the lower layer OMS facilities.
BANDWL-{1-6,12-17}-{1-32}-{RX,TX}-ALL
Identifies all of the allocated wavelength channels included in any of the lower layer OMS facilities.
OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the endpoints of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]- [WAVELENGTH]. WAVELENGTH is in the form of 15xx.yy.
BANDWL-[{1-50}-]{1-6,12-17}-{1-32}-{RX,TX,PT}-ALL
OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the endpoints of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]- [WAVELENGTH]. WAVELENGTH is in the form of 15xx.yy.
27.6 BITS
AID for building integrated timing supply (BITS). Table 27-6 lists the BITS AIDs and their descriptions.
Table 27-6 BITS
Pattern
Description
ALL
The ALL AID is applicable to RTRV commands only (RTRV-BITS, RTRV-ALM-BITS, and RTRV-COND-BITS). The All AID is equivalent to BITS-ALL for these commands. For RTRV-ALM-SYNCN and RTRV-COND-SYNCN, the ALL AID translates to BITS-ALL, SYNC-BITS1, and SYNC-BITS2.
BITS-ALL
BITS AIDs of both BITS-1 and BITS-2 in the RTRV-BITS command.
BITS[<SHELFID>]-ALL
BITS shelf ID of both BITS-1 and BITS-2 in the RTRV-BITS command.
BITS[<SHELFID>]-{1,2}
Individual BITS AID.
SYNC[<SHELFID>]-BITS{1,2}
BITS-OUT AIDs of BITS-1 and BITS-2. These AIDs are applicable only in ED-BITS and RTRV-BITS commands and are used for setting and retrieving the BITS-OUT parameters.
27.7 CHANNEL
Accesses the Optical Channel (OCH) layer of optical networking/client units. Table 27-9 lists the CHANNEL AIDs and their descriptions.
Table 27-7 CHANNEL
CHANNEL Values
Description
ALL
ALL OCHs of the NE. The ALL AID is applicable for retrieve-only commands.
ACHAN[-{1-50}]-{2-7}-{1}-{1}
Identifies the OCH Facility of Aggregate port of 100G-LC-C Card.
CHAN[-{1-50}]-{2-7}-{2}
Identifies the Fixed Trunk or the Coherent Trunk on 100G-LC-C Card.
CHAN[-{1-50}]-{1-6,12-17}-ALL
All the channels of an Optical Transponder/Muxponder. The format is CHAN-[SLOT]-ALL
CHAN[-{1-50}]-{1-6,12-17}-{1-32}- ALL
All the channels in an Optical Multiplexer/Demultiplexer 32WSS unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-ALL.
CHAN[-{1-50}]-{1-6,12-17}-{1-32}- {RX,TX}
The Receive/Transmit channels in an Optical Multiplexer/Demultiplexer (32DMX, 32MUX) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].
CHAN[-{1-50}]-{1-6,12-17}-{1-32}- {RX,PT}
The Receive/Pass-through channels in an Optical 32WSS unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].
CHAN[-{1-50}]-{1-5,12-16}-{1-40}-A
LL
All the channels in Optical Multiplexer/Demultiplexer/WSS (40Ch) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-ALL.
CHAN[-{1-50}]-{1-5,12-16}-{1-40}-{
RX,TX}
The receive/transmit channels in an Optical Multiplexer/Demultiplexer (40Ch) unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].
CHAN[-{1-50}]-{1-5,12-16}-{1-40}-{
RX,PT}
The Receive/Pass-through channels in an Optical WSS (40Ch) unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].
CHAN[-{1-50}]-{1-6,12-17}-{1-4}-ALL
All the Channels in an OADM (AD-1C-xx.x, AD-2C-xx.x, AD-4C-xx.x) unit or Optical Multiplexer/Demultiplexer (4MD-xx.x) units. The format is CHAN-[SHELF]-[SLOT]-[PORT]-ALL.
CHAN[-{1-50}]-{1-6,12-17}-{1-4}- {RX,TX}
The Receive/Transmit Channels in an OADM (AD-1C-xx.x, AD-2C-xx.x, AD-4C-xx.x) unit or Optical Multiplexer/Demultiplexer (4MD-xx.x) unit. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[DIRECTION].
CHAN[-{1-50}]-{1-6,12-17}-{2,3}
A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G, TXP_MR_10E, and TXP_MR_2.5G cards use CHAN-[SHELF]-SLOT-2 for the one NCS Facility. The TXPP_MR_2.5G card uses CHAN-[SHELF]-SLOT-{2,3} for the two NCS Facilities. The format is CHAN-[SHELF]-[SLOT]-[PORT].
CHAN[-{1-50}]-{1-6,12-17}-{5}
A single channel of an Optical Muxponder. The TXP_MR_10G and TXP_MR_10E cards use CHAN-[SHELF]-SLOT-5 for the one NCS facility. The TXP_MR_10G uses the CHAN-[SHELF]-SLOT-5 for the one NCS facility. The format is CHAN-[SHELF]-[SLOT]-[PORT].
CHAN[-{1-50}]-{1-6,12-17}-{9,10}
A single channel of an Optical Muxponder. The MXP_MR_10DME_C and MXP_2.5G_10G cards use CHAN-[SHELF]-SLOT-9 for the one NCS Facility. The MXPP_2.5G_10G card uses CHAN-[SHELF]-SLOT-{9,10} for the two NCS Facilities. The format is CHAN-[SHELF]-[SLOT]-[PORT].
CHAN[-{1-50}]-{1-6,12-17}-{3,4}-{1}
A single channel of an Optical Muxponder. The 10GE-XP uses CHAN-[SHELF]-SLOT-{3,4}-1 for the two NCS facilities. The format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].
CHAN[-{1-50}]-{1-6,12-17}-{21,22}-{
1}
A single channel of an Optical Muxponder. The GE-XP uses CHAN-[SHELF]-SLOT-{11,12}-1 for the two NCS facilities. The format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].
CHAN-[{1-50}-]{1-6,12-17}-{1-32}-
{RX,TX,PT}
OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION].
CHAN-[{1-50}-]{1-6,12-17}-{1-32}-
ALL
OCH is the termination point of OCHNC connections and it is also used to report alarms and conditions eventually notified by the node connection anomalies. Because the end points of an OCHNC connection can be both at the OCH filter level and at the node LINE OTS single wavelength level, this logical termination is useful to represent univocally a wavelength termination independently by the physical port it is contained in. The format is CHAN-[SHELF]-[SLOT]-[PORT]-[PORTDIRECTION]-[WAVELENGTH (in the form of 15xx.yy)].
CHAN[-{1-50}]-{1-6,12-17}-{19}-{1}
A single channel of an ADM-10G card. ADM-10G uses CHAN-[SHELF]-SLOT-19 for one NCS Facility. Format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].
CHAN[-{1-50}]-{1-6,12-17}-{17,18}-
{1}
The NCS interlinks between two peer ADM-10G cards. ADM-10G uses CHAN-[SHELF]-SLOT-{17,18} for the two NCS interlinks Facilities. Format is CHAN-[SHELF]-[SLOT]-[PPM]-[PORT].
CHAN[-{1-50}]-{1-6,12-17}-{19}-{1}
A single channel of an ADM-10G card. ADM-10G uses CHAN-[shelf]-slot-19 for the 1 NCS Facility. Format is CHAN-[shelf]-[slot]-[ppm]-[port].
CHAN[-{1-50}]-{2-7}-{1-10}-{1}
Identifies OCH interface of SFP+ ports on 10x10G-LC and CFP ports on CFP-LC.
CHAN[-{1--0}]-{1-6,12-17}-{17,18}-{1
The NCS Interlinks between 2 peer ADM-10G cards. ADM-10G uses CHAN-[shelf]-slot-{17,18} for the 2 NCS Interlinks Facilities. Where format is CHAN-[shelf]-[slot]-[ppm]-[port]. In Release 9.0 or later, Port Number 18 can be used as an optical channel in the single card mode, the AID and the format remain the same.
PCHAN-ALL
All the Channels in all the Passive patch panel module where format is PCHAN-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
PCHAN-{1-96}-ALL
All the Channels in a Passive patch panel module where format is PCHAN-[id]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
PCHAN-{1-96}-{1-4}-ALL
All the TX and RX Channels in a port of 15216-FLD-xx-x, passive modules where format is PCHAN-[id]-[port]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
PCHAN-{1-96}-{1-4}-{RX-TX}
All the TX and RX Channels in a port of 15216-FLD-xx-x, passive modules where format is PCHAN-[id]-[port]-[direction]. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
PCHAN-{1-96}-{1-40}-ALL
All the TX and RX Channels in a port of 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
PCHAN-{1-96}-{1-40}-{RX,TX}
The Recieve/Transmit Channels in a 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-[direction]. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
PCHAN-{1-96}-{1-40}-ALL
All the TX and RX Channels in a port of 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-ALL. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
PCHAN-{1-96}-{1-40}-{RX,TX}
The Recieve/Transmit Channels in a 15216-MD-ODD, 15216-MD-EVEN passive modules where format is PCHAN-[id]-[port]-[direction]. This AID is applicable to OCH commands like ENT/DLT/RTRV-LNK, ENT/DLT/ED/RTRV-OCHNC, RTRV-OCH, ENT/ED/RTRV/OPR/RLS/DLT-CPS, SET/RTRV-HOP-CPS.
VCHAN[-{1-50}]-{2-7}-{1-2}
Indentifies the OCH Facility of the Backplane Virtual ports on 100G-LC-C card.
FPCHAN-{1-126}-{1-48}-{RX-TX}
All the ADD/DROP ports of MD-48-EVEN/MD-48-ODD passive module where format is FPCHAN-[id]-[port]-[DIR}.
27.8 CHGRP
AID for the Channel Group (CHGRP). Table 27-8 lists the CHGRP AIDs and their descriptions.
Table 27-8 CHGRP
Pattern
Description
ALL
The ALL aid is applicable for RTRV-only commands, basically the RTRV-rr type of commands. For example, RTRV-CHGRP with ALL aid returns all CHGRP ports on the GE_XP and 10GE_XP cards.
CHGRP-[{1-50}]-{1-6,12-17}-{1-11}
Channel group AID on GE_XP and 10GE_XP cards. The format is CHGRP-[SHELF]-[SLOT]-[CHGRP]
27.9 COM
Table 27-9 lists the common (COM) AIDs and their descriptions.
Table 27-9 COM
Pattern
Description
COM
Common
27.10 CrossConnectId
Table 27-10 lists the CrossConnectId AIDs and their descriptions.
Table 27-12 lists the environmental (ENV) AIDs for the AIC-I cards and their descriptions.
Table 27-12 ENV
Pattern
Description
ALL
The ALL AID applies to retrieve-only commands: RTRV-ALM-ENV, RTRV-COND-ENV, RTRV-ATTR-CONT, and RTRV-ATTR-ENV.
ENV-IN-ALL
Environmental AID for ALL environmental alarms.
ENV-IN[-{1-50}]-ALL
Environmental AID for ALL multishelf environmental alarms.
ENV-IN[-{1-50}]-{1-4}
Environmental AID for the AIC-I card. "IN" is used for environmental alarms.
ENV-IN[-{1-50}]-{1-20}
Environmental AID for the AIC-I card. "IN" is used for environmental alarms.
ENV-IN[-{1-50}]-{1-32}
Environmental AID for AIC-I card extensions. "IN" is used for environmental alarms.
ENV-IN[-{1-50}]-{1-3}
Environmental AID for the AIC-I card. "IN" is used for environmental alarms.
ENV-IN[-{1-50}]-{1-6}
Environmental AID. "IN" is used for environmental alarms.
ENV-OUT-ALL
Environmental AID for AIC-I cards. "OUT" is used for environmental controls.
ENV-OUT[-{1-50}]-ALL
Environmental AID for AIC-I cards. "OUT" is used for environmental controls.
ENV-OUT[-{1-50}]-{1-4}
Environmental AID for AIC-I cards. "OUT" is used for environmental controls.
ENV-OUT[-{1-50}]-{1-16}
Environmental AID for AIC-I card extensions. "OUT" is used for environmental controls.
ENV-OUT[-{1-50}]-{1-2}
Environmental AID for AIC-I cards. "OUT" is used for environmental controls.
ENV-{IN,OUT}[-{1-50}]-{1-16}
ENV-IN[1-16} is used for the environmental alarm AID. ENV-OUT-{1-16} is used for the external control AID.
27.13 EQPT
Table 27-13 lists the equipment (EQPT) AIDs for the AIC-I cards and their descriptions. EQPT AIDs are used to access specific cards.
AID for CXP port on 100G-LC-C and 10x10G-LC: APPM-[SLOT]-[PPM]-[PORT]
Table 27-13 EQPT
Pattern
Description
AIP-[-{1-50}]
The AID for the alarm interface panel (AIP). It is used for RTRV-INV output only.
AIP-ALL
The AID for all of the AIPs in any shelf of the node. It is used for RTRV-INV output only.
ALL
Only used for RTRV-INV, RTRV-EQPT, RTRV-ALM-EQPT, and RTRV-COND-EQPT commands. RTRV-INV returns all the inventory information for the NE. The NCS includes the multiservice cards, common control cards, and the AIP, BP, and FAN. RTRV-ALM-EQPT and RTRV-COND-EQPT with the ALL AID return EQPT and PWR-A and PWR-B type of alarms and conditions.
BIC-ALL
AIDs for the backplane interface connectors (BICs): BIC-A and BIC-B. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
BIC-[-{1-50}]-ALL
AIDs for the BICs: BIC-A and BIC-B of a single shelf in a multishelf node. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
BIC[-{1-50}]-{A,B}
AIDs for the BICs. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
BP[-{1-50}]
The AID for the backplane. It is used for RTRV-INV output only.
BP-ALL
The AID for all of the backplanes in any shelf on the multishelf node. It is used for RTRV-INV output only.
FAN[-{1-50}]
The AID for the fan tray. It is used for RTRV-INV output only.
FAN-ALL
The AID for all of the fan tray in all the shelves of a multishelf node. It is used for RTRV-INV output only.
PPM-{1-6,12-17}-1
PPM for the OC192-XFP card. Format is PPM-[SLOT]-[PPM].
PPM-{1-6,12-17}-{1-4}
Pluggable Port Module for MRC-4. Format is PPM-[SLOT]-[PPM]. It is not applied on CHG-EQPT, and RMV/RST/ED-EQPT commands.
PPM-{1-6,12-17}-{1-50}
Pluggable Port Module for MRC-12 card. Format is PPM-[SLOT]-[PPM]. It is not applied on CHG-EQPT, and RMV/RST/ED-EQPT commands.
PPM[-{1-50}]-{1-6,12-17}- {1-4}
PPM AID for NCS MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_10E cards. Format of AID is PPM-[SLOT]-[PPM].
PPM[-{1-50}]-{1-6,12-17}- {1-8}
PPM AID for the MXP_MR_2.5G and MXPP_MR_2.5G cards. Format of AID is PPM-[SLOT]-[PPM].
PUNIT-ALL
The whole NE Passive patch panel equipment AIDs. These AIDs are applicable to EQPT commands like ENT/DLT/RTRV/ED-EQPT commands.
PUNIT-{1-96}
Individual equipment AID of the Passive patch panel units where format is PUNIT-[id]. These AIDs are applicable to EQPT commands like ENT/DLT/RTRV/ED-EQPT commands.
PWR-ALL
AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
PWR[-{1-50}]-{A,B}
AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
PWR[-{1-50}]-ALL
AIDs for all of the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
SLOT-ALL
All of the NE equipment AIDs.
SLOT[-{1-50}]-{1-17}
EQPT AID where the format is SLOT-[SLOT].
SLOT[-{1-50}]-{1-6,12-17}
Individual equipment AID of the multiservice card units or slots where the format is SLOT-[SLOT].
SPPM[-{36-55}]-{1-44}
PPM for the CPT 50 panel GIGE ports card. The format is SPPM-[PTSA]-[PPM].
SFOPPM[-{36-55}]-{45-48}
PPM for the CPT 50 panel 10GIGE ports card. The format is SFOPPM-[PTSA]-[PPM].
PTSYS[-{1}]-ALL
PT System AID for the CPT system. The format is PTSYS-{PTSYSID}.
FOG[-{1}]-{36-55}-ALL
Fan-Out-Group AID for connecting the CPT 50 panel to fabric and line cards. The format is FOG-{PTSYSID}-{FOGID}.
27.14 ETH
Ethernet (ETH) AIDs are used to access the ethernet port. Table 27-8 lists the ETH AIDs and their descriptions.
Table 27-14 ETH
Pattern
Description
ETH-{1,2,5,6}-{1-6}
Format is ETH-slot-port. Port numbering is 1-based.
ETH[-{1-50}]-{1-6,12-17}-{1-22}-{1}
Ethernet AID for ethernet port on GE_XP and 10GE_XP cards. The format is ETH-[SHELF]-[SLOT]-[PPM]-[PORT.
ETH[-{1-50}]-{1-6,12-17}-{1-22}-{1}-{1-4096}
Ethernet CEPID AID for ethernet port CEP on GE_XP and 10GE_XP cards. The format is ETH-[SHELF]-[SLOT]-[PPM]-[PORT]-[CEPID], where [CEPID] is the connection end point identifier, that identifies a single 1 Gbit/sec circuit inside an ethernet port.
27.15 FACILITY
Facilities AIDs are used to access specific ports. Table 27-15 lists the FACILITY AIDs and their descriptions. The FACILITY AID formats are as follows:
•Format for DS3i-N-12 electrical facilities: FAC-[SLOT]-[PORT]
•Format for POS ports: VFAC-[SLOT]-[PORT]
•Format for POS port with PIM and PPM: VFAC-[SLOT]-[PIM]-[PPM]-[PORT]
•Format for 100G-LC-C, 10x10G-LC, and CFP-LC cards: VLINE-[SLOT]-[PPM]-[PORT]-[SUBLANE-NO] Sublane Aid for all sublanes
•Format for CXP port on 100G-LC-C card: AGGR-[SLOT]-[APPM]-[PORT].
•Format for SFP+ ports on for 10x10G-LC and CFP-LC cards: VFAC-[SLOT]-[PPM]-[PORT]
Table 27-15 FACILITY
Pattern
Description
ALL
The ALL AID is applicable for retrieve-only commands (RTRV-xx type of commands), for example: RTRV-STM16 with an ALL AID returns all STM16 facilities on the node.
AGGR[-{1-50}]-{2-7}-{1}-{1}
Facility AID for CXP port on 100G-LC-C card.
FAC[-{1-50}]-{1-4,14-17}-{1-8}
Facilities for an STM1 card where the format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{1-6,12-17}-1
Facility AID for the one client (CLNT) port on a TXP_MR_10G, TXP_MR_2.5G, TXP_MR_2.5G, or TXPP_MR_2.5G card where the format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{1-6,12-17}-ALL
All the facilities of an input/output (I/O) unit or slot where the format is FAC-[SLOT]-[ALL].
FAC[-{1-50}]-{1-6,12-17}-{0-11}
Facilities for the Ethernet front-end ports on the ML100T-12 card. Ports are numbered starting with 0 (for the ML100T-12, the first port is FAC-SLOT-0, second port is FAC-SLOT-1, etc., and the last port is FAC-SLOT-1l; for the ML1000-2, the first port is FAC-SLOT-0 and second port is FAC-SLOT-1). The format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{1-6,12-17}-{0-1}
Facilities for the Ethernet back-end ports on the ML1000-2 card. Ports are 0-based, (for example, the first port is FAC-SLOT-0 and the second port is FAC-SLOT-1). The format is FAC-[SLOT]-[PORT].
FAC-{1-6,12-17}-{1-8}
Facility AID for the Ethernet front-end ports on the CE-100T-8 card The format is FAC-[SLOT]-[PORT].
FAC-{1-6,12-17}-{0-11}
Facility AID for the Ethernet front-end ports on the MS-ISC-100T The first port is FAC-SLOT-0, the second port is FAC-SLOT-1, and so on. The last port is FAC-SLOT-11. The format is FAC-[SLOT]-[PORT].
Facility AIDs for the DS3i-N-12 VC416 backplane rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available.
FAC[-{1-50}]-{1-6,12-17}-{1-12,14,16,18,20,22,24}
Facility AIDs for DS3i-N-12 VC44 backplane rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available.
FAC[-{1-50}]-{1-6,12-17}-{1-4}
Facility AID for the four CLNT facilities on the MXP_2.5G_10G card. Facility AID for 4-Port G1000/FC_MR-4 card. Facility AID for creating and editing cross-connects (VC3, VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C) for the 4-Port G1000/FC_MR-4 card where format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{1-6,12-17}-{1-6}
Facilities for the DS3i-N-12 card where the format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{1-6,12-17}-{1}
Facility AID for the 1-Port STM4, STM16, and STM1 in OSC-CSM cards. Facility AID for the client ports on the MXP/TXP and TXP_MR_2.5G cards where format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{5,6,12,13}-{1}
Facility AID for the STM16/STM64 cards. The STM16/STM64 cards can only use Slot 5, Slot 6, Slot 12, and Slot 13 where format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{8,10}-{1}
Facility AID for the OSCM card where format is FAC-[SLOT]-[PORT].
FAC[-{1-50}]-{1-6,12-17}-1-1
Facility AID for the TXP_MR_2.5G, TXPP_MR_2.5G, TXP_MR_10E, TXP_MR_10EX and TXPP_MR_10EX cards in the format of:FAC-[shelf]-[slot]-[ppm]-[port].
VFAC[-{1-50}]-{1-6,12-17}-{0-1}
Facilities for the back-end packet-over-NCS (POS) ports on the ML-Series card. Port numbering is 0-based (first POS port is VFAC-SLOT-0, second POS port is VFAC-SLOT-1). VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C for the ML1000 and ML100T cards. Format is VFAC-[SLOT]-[PORT].
VFAC-{1-6,12-17}-{0-15}
Facilities for ML-MR-10 back-end packet-over-NCS (POS) ports in MLMR-AUTO Mode. ML-MR-10 has 16 POS Ports. POS Ports are 0-Based. Format is VFAC-[slot]-[port]
VFAC[-{1-50}]-{1-6,12-17}-{1,2}
GFP facilities on the MXP-MR-2.5G and MXPP-MR-2.5G cards.
VFAC[-{1-50}]-{1-6,12-17}-{1,2} -{1,8}
GFP client facilities for MXP-MR-2.5G and MXPP-MR-2.5G cards
FAC[-{1-50}]-{1-4,14-17}-{1-4}
Facility AID for four Ether Ports on the CE1000 card.
VFAC[-{1-50}]-{1-4,14-17}-{1-4}
Facility AID for the back-end ports on the CE1000 card.
VFAC[-{1-50}]-{2-7}-{1-10}-{1}
Facility AID for SFP+ ports on 10x10G-LC and CFP ports on Fumaiolo cards.
VLINE[-{1-50}]-{2-7}-{1-2}-{1}-{1-12}
Facility AID for sublanes on 10x10G-LC card only.
SFAC[-{36-55}]-{1-44}-1
GIGE facilities on the CPT 50 panel. The format is SFAC-[PTSAID]-[PPM]-[PORT].
SFOFAC[-{36-55}]-{45-48}-1
10GIGE facilities on the CPT 50 panel. The format is SFOFAC-[PTSAID]-[PPM]-[PORT].
27.16 FPLINE
FPLINE AIDs are used on passive OTS ports of MD-48-EVEN/MD-48-ODD passive module. Table 27-16 lists the FPLINE AIDs and their descriptions. The FPLINE AID format is: FPLINE-ID-PORT-DIR-LABEL
Table 27-16 FPLINE
Pattern
Description
FPLINE-{1-126}-{1-48}-{RX-TX}
All the ADD/DROP ports of MD-48-EVEN/MD-48-ODD passive module where format is FPCHAN-[id]-[port]-[DIR}.
FPLINE-{1-126}-{1-20}-{RX-TX}
All the IN/OUT ports of MF-DEG-5 passive module where format is FPCHAN-[id]-[port]-[DIR}.
FPLINE-{1-126}-{1-32}-{RX-TX}
All the IN/OUT ports of MF-UPG-4 passive module where format is FPCHAN-[id]-[port]-[DIR}.
FPLINE-{1-126}-{1-8}-{RX-TX}
All the ports of MF-MPO-8LC passive module where format is FPCHAN-[id]-[port]-[DIR.
FPLINE-{1-126}-{1-8}-{RX-TX}
All the IN/OUT ports of MF-4x4-COFS passive module where format is FPCHAN-[id]-[port]-[DIR}.
FPLINE-{1-126}-{1-17}-{RX-TX}
All the IN/OUT ports of MF-16AD-CFS passive module where format is FPCHAN-[id]-[port]-[DIR}.
27.17 IPADDR
Table 27-17 lists the IP address (IPADDR) AIDs and their descriptions.
Table 27-17 IPADDR
Pattern
Description
111.222.333.444
Standard 4-part IP address notation
ALL
ALL
27.18 LINE
The LINE AID is used to access the Optical Transport Section (OTS) layer of optical networking units. Applicable only to NCS AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O, and 32DMX-O cards. The format is LINE-[SLOT]-[PORT]-[DIRECTION]. Table 27-18 lists the LINE AIDs and their descriptions.
Table 27-18 LINE
Values
Description
ALL
All of the OTSs of the NE. The ALL AID applies to retrieve-only commands.
LINE-{1-6,12-17}-{1-2}-ALL
All the lines in a OPT-PRE, OCS-CSM, AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, and AD-4C-xx.x cards.
LINE-{1-6,12-17}-{1-2}-{RX,TX}
The receive/transmit lines in a OPT-PRE, AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, and AD-4C-xx.x cards.
LINE-{1-6,12-17}-{1-3}-{RX,TX}
The receive/transmit lines in a OPT-BST cards.
LINE-{8,10}-{1}-ALL
All the lines in a OSCM cards.
LINE-{8,10}-{1}-{RX,TX}
The receive/transmit lines in OSCM car
LINE-[{1-50}-]{1-6,12-17}-{1}- {RX,TX}
For booster cards, there is an input OTS for LINE(1) and an output OTS (amplified) for amplification stage COM(2), two OTS for input line COM(2) and output LINE(1), and 2 OTS for OSC(3) add and drop service channel.
LINE-[{1-50}-]{1-6,12-17}-{2}- {RX,TX}
LINE-[{1-50}-]{1-6,12-17}-{3}- {RX,TX}
LINE-[{1-50}-]{1-6,12-17}-{1-3}-ALL
LINE-[{1-50}-]{1-6,12-17}-{1}- {RX,TX}
Preamplifier card with 2 stages of amplification; input OTS for LINE(1) and an output OTS (amplified) for amplification stage COM(2), two OTS for input line COM(2) and output LINE(1), and two OTS for OSC(3) add and drop service channel and output and an input OTS for the DCU(2).
LINE-[{1-50}-]{1-6,12-17}-{2}- {RX,TX}
LINE-[{1-50}-]{1-6,12-17}-{3}- {RX,TX}
LINE-[{1-50}-]{1-6,12-17}-{4}- {RX,TX}
LINE-[{1-50}-]{1-6,12-17}-{1-4}-ALL
LINE-[{1-50}-]{1-6,12-17}-1-RX For input OTS
For demultiplexer cards, there is an OTS for input line and up to 32 OCH for drop channel connectors. A demultiplexer is a unidirectional unit.
LINE-[{1-50}-]{1-6,12-17}-1-ALL
CHAN-[{1-50}-]{1-6,12-17}-{1-32}-TX for Drop OCH
CHAN-[{1-50}-]{1-6,12-17}-{1-32}- ALL
LINE-[{1-50}-]{1-5,12-16}-{1}- {RX,TX} (EXP)
Wavelength switch selector card has input and output OTS for signals coming from amplifier units COM(2), input and output OTS for signal continuing to next WSS unit in the node EXP(1), and an output PT(3) drop port for the signal continuing to 32DMX-L card. It also has 32 internal OCH pass-through channels (PT) and 32 external input channels (ADD). This unit is 2 slots wide.
LINE-[{1-50}-]{1-5,12-16}-{2}- {RX,TX} (COM)
LINE-[{1-50}-]{1-5,12-16}-{3}-{TX} (DROP)
LINE-[{1-50}-]{1-5,12-16}-{1-3}-ALL
CHAN-[{1-50}-]{1-5,12-16}-{1-32}- {RX} (ADD)
CHAN-[{1-50}-]{1-5,12-16}-{1-32}- {PT} (PT)
CHAN-[{1-50}-]{1-5,12-16}-{1-32}- ALL
LINE-[{1-50}-]{1-6,12-17}-{1}- {RX,TX} (EXP)
Multiring/mesh unit has 6 OTS connectors: two are the input and output OTS for signal coming from amplifier units COM(1), the other four are for the split 50/50 signals continuing to AD, MUX/DMX, and WSS units. Because the incoming signal is split into two separate signals, there are two sets of input and output EXP ports (2 and 3).
LINE-[{1-50}-]{1-6,12-17}-{2}- {RX,TX} (COM)
LINE-[{1-50}-]{1-6,12-17}-{3}- {RX,TX} (EXP to other ring)
LINE-[{1-50}-]{1-6,12-17}-{1-3}-ALL
PLINE-ALL
All the EXP/COMM/DC lines in all the Passive patch panel module where format is PLINE-ALL.
PLINE-{1-96}-ALL
All the EXP/COM/DC lines in a Passive patch panel module where format is PLINE-[id]-ALL.
PLINE-{1-96}-{1}-ALL
All the IN and OUT DC/COM lines in DCU,15216-MD-40-ODD/EVEN passive modules where format is PLINE-[id]-[port]-ALL
PLINE-{1-96}-{1-3}-ALL
All the IN and OUT COM lines in 15216-MD-ID-50 passive module where format is PLINE-[id]-[port]-ALL.
PLINE-{1-96}-{1-20}-ALL
All the IN COM and OUT EXP lines in PP-MESH-4 passive module where format is PLINE-[id]-[port]-ALL.
PLINE-{1-96}-{1-72}-ALL
All the IN COM and OUT EXP lines in PP-MESH-8 passive module where format is PLINE-[id]-[port]-ALL.
PLINE-{1-96}-{1}-{RX-TX}
The Receive or Transmit DC/COM lines in DCU,15216-MD-40-ODD/EVEN passive modules where format is PLINE-[id]-[port]-[direction]
PLINE-{1-96}-{1-3}-{RX-TX}
The Recieve or Transmit COM line in a 15216-MD-ID-50 passive module where format is PLINE-[id]-[port]-[direction].
PLINE-{1-96}-{1,6,11,16}-RX
The Recieve COM lines in a PP-MESH-4 passive module where format is PLINE-[id]-[port]-[direction].
PLINE-{1-96}-{2-5,7-10,12-15,17-20}-TX
The Transmit EXP lines in a PP-MESH-4 passive module where format is PLINE-[id]-[port]-[direction].
PLINE-{1-96}-{1,10,19,28,37,46,55,64}-RX
The Recieve COM line in a PP-MESH-8, passive modules where format is PLINE-[id]-[port]-[direction].
The Transmit EXP line in a PP-MESH-8, passive modules where format is PLINE-[id]-[port]-[direction].
PLINE-{1-96}-{1}-{RX-TX}
The Recieve or Transmit COM line in a 15216-FLD-xx-x, passive modules where format is PLINE-[id]-[port]-[direction].
PLINE-{1-96}-{2}-{RX-TX}
The Recieve or Transmit EXP line in a 15216-FLD-xx-x, passive modules where format is PLINE-[id]-[port]-[direction].
27.19 LINEWL
The line wavelength (LINEWL) AID identifies a wavelength channel included in any of the lower layer OTS facilities. Table 27-20 lists the LINEWL AIDs and their descriptions.
Table 1:
Values
Description
LINEWL[-{1-50}]-{1-6,8,10,12-17}-ALL
All the Optical Channels representing single wavelength inside OTS facility of a card configured in specified slot. The format is LINE-[SHELF]-[SLOT]-ALL
LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-ALL
The Optical Channel representing single wavelength inside OTS facility in a 32-DMX-O, 32-DMX, 32-DMX-L, 32-MUX-O, 40-DMX-C, 40-MUX-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.
LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-<wlen>
The Optical Channel representing single wavelength inside OTS facility in a 32-DMX-O, 32-DMX, 32-DMX-L, 32-MUX-O, 40-DMX-C, 40-MUX-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].
LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-ALL
The Optical Channel representing single wavelength inside OTS facility in a 32-WSS, 40-WSS-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.
LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside OTS facility in a 32-WSS, 40-WSS-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].
LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL
All the Optical Channel representing single wavelength inside OTS facility in a AD-1B, AD-4B, AD-1C, AD-2C, AD-4C units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL
LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside OTS facility in a AD-1B, AD-4B, AD-1C, AD-2C, AD-4C units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN]
LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL
All the Optical Channel representing single wavelength inside OTS (COM=1, DC=2) facility in an OPT-PRE unit. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL
LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside OTS (COM=1, DC=2) facility in a OPT-PRE units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-<WLEN>
LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-ALL
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C, and OPT-AMP-23-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.
LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C, OPT-AMP-23-C, and OPT-AMP-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].
LINEWL[-{1-50}]-{1-6,12-17}-{1,3,4}-{RX,TX}-ALL
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3, DC=4) facility in a OPT-AMP-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3, DC=4) facility in a OPT-AMP-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].
LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-ALL
All the Optical Channel representing single wavelength inside OTS (COM) facility in a OPT-PRE units. The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL
LINEWL[-{1-50}]-{1-6,12-17}-{1}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside OTS (COM) facility in a OPT-PRE units.The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN]
LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-ALL
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C and OPT-AMP-23-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.
LINEWL[-{1-50}]-{1-6,12-17}-{1,3}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=3) facility in a OPT-BST, OPT-BST-E, OPT-BST-L, OPT-AMP-L, OPT-AMP-17-C and OPT-AMP-23-C cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].
LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-ALL
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=2) facility in a OSC-CSM cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-ALL.
LINEWL[-{1-50}]-{1-6,12-17}-{1-2}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside OTS (COM=1, LINE=2) facility in a OSC-CSM cards. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN]-[WLEN].
LINEWL- [{1-50}]-{1-5,12-16}-{1-8}-{RX}-<WLEN>
The Optical Channel representing single wavelength inside EXP lines from all the other WXC cards in a 40-WX-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].
LINEWL- [{1-50}]-{1-5,12-16}-{9}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside ADD/DROP line to/from MUX/DMX/WSS cards in a 40-WXC-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].
LINEWL- [{1-50}]-{1-5,12-16}-{10}-{TX}-<WLEN>
The Optical Channel representing single wavelength inside EXP line in a 40-WXC-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].
LINEWL- [{1-50}]-{1-5,12-16}-{11}-{RX,TX}-<WLEN>
The Optical Channel representing single wavelength inside COM line in a 40-WXC-C card. The format is LINEWL-[SHELF]-[SLOT]-[PORT]-[DIRN].
LINEWL[-{1-50}]-{1-6,12-17}-{1-3}-{RX,TX}-<LABEL>
The Optical Channel representing OCHTERM interface in a OPT-EDRA/OPT-EDFA/16-WXC-FS units.The format is LINE-[SHELF]-[SLOT]-[PORT]-[DIRN]-[LABEL].
27.20 LNKTERM
Link Termination (LNKTERM) AIDs are used to access the termination points of a provisionable patchcord. Table 27-19 lists the LINKTERM AIDs and their descriptions.
Table 27-19 LNKTERM
Pattern
Description
ALL
Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands.
LNKTERM-ALL
Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands.
LNKTERM-{1-65535}
Indicates a single provisionable patchcord termination point on a node.
27.21 MSSPR
Multiplex section-shared protection ring (MSSPR) AIDs are used to access the MS-SPRing of the NE. Table 27-20 lists the MSSPR AIDs and their descriptions.
Table 27-20 MSSPR
Pattern
Description
ALL
ALL AID for all MS-SPRings in the NE. The ALL AID is applicable for retrieve-only commands like RTRV-MSSPR, RTRV-ALM-MSSPR, and RTRV-COND-MSSPR.
MSSPR-RINGID
MS-SPRing AID is keyword MS-SPRing followed by RINGID. RINGID is a string of up to 6 characters; valid characters are [A-Z,0-9] (case insensitive).
27.22 OPM
Optical power monitoring (OPM) AIDs represent the single wavelength inside an optical power monitoring object. Table 27-21 lists the OPM AIDs and their descriptions.
Table 27-21 OPM
Values
Description
ALL
The first ID represents the shelf, the second ID represents the slot, and the last ID is the wavelength, represented in the form of 15xx.yy nanometers. The last index of the wavelength is the value of the wavelength as described in OPTICAL_WLEN.
OPM[-{1-50}]-{1-5,12-16}-ALL
OPM[-{1-50}]-{1-5,12-16}-<WLEN>
27.23 OSC
Optical service channel (OSC) AIDs are used to access the OSC of the NE. Table 27-22 lists the OSC AIDs and their descriptions.
Table 27-22 OSC
Values
Description
ALL
All of the OSCs of the NE. The ALL AID applies to the retrieve-only commands.
OSC-RINGID
RINGID is a string of up to six characters, valid characters are [A-Z,0-9] (case insensitive).
27.24 PRSLOT
Valid protection slots for the electrical cards. Format is SLOT-[SLOT]. Table 27-23 lists the PRSLPT AIDs and their descriptions.
Table 27-23 PRSLOT
Pattern
Description
NULL
Indicates there is no protection group. Used when trying to delete a protection group.
SLOT-1
Slot 1 of an NE.
SLOT-2
Slot 2 of an NE.
SLOT-3
Slot 3 of an NE.
SLOT-5
Slot 5 of an NE.
SLOT-6
Slot 6 of an NE.
SLOT-13
Slot 13 slot of an NE.
SLOT-15
Slot 15 slot of an NE.
SLOT-17
Slot 17 slot of an NE.
27.25 RFILE
Table 27-24 lists the file transfer type (RFILE) AIDs and their descriptions.
Table 27-24 RFILE
Pattern
Description
RFILE-DB
Transferring the provisioning database.
RFILE-LOG
Transferring a log file.
RFILE-PKG
Transferring a software package.
RFILE-COMPDB
Transferring the provisioning and system database.
27.26 SHELF
The SHELF AID identifies a shelf within a node. SHELF is applicable only to nodes that are set to MULTISHELF or MULTISHELFETH mode. Table 27-25 lists the SHELF AIDs and their descriptions.
Table 27-25 SHELF
Pattern
Description
SHELF-ALL
All of the shelves in the node.
SHELF-{1-50}
A specific shelf in the node (shelf 1 through 30).
27.27 SYN
Table 27-26 lists the synchronization (SYN) AIDs and their descriptions.
Table 27-26 SYN
Pattern
Description
SYNC[-{1-50}]-ALL
ALL synchronization AID (values 1 to 8 is the shelf ID).
SYNC[-{1-50}]-NE
NE synchronization AID (values 1 to 8 is the shelf ID).
SYNC[-{1-50}]-{BITS1,BITS2}
BITS synchronization AID (values 1 to 8 is the shelf ID).
27.28 SYN_SRC
Table 27-27 lists the synchronization source (SYN_SRC) AIDs and their descriptions.
Table 27-27 SYN_SRC
Pattern
Description
BITS-1
Synchronization source is BITS-1. Format is BITS-[PORT].
BITS-2
Synchronization source is BITS-2. Format is BITS-[PORT].
FAC-{1-4,11-14}-{1-4}
Synchronization source is the 4-port STM64. Format is FAC-[SLOT]-[PORT].
FAC-{1-6,12-17}-{1-4}
Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT].
FAC-{1-6,12-17}-{1}
Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT].
FAC-{5,6,12,13}-{1}
Synchronization source is the optical card (STM16 and STM 64) facility. Format is FAC-[SLOT]-[PORT].
INTERNAL
Set the SYN_SRC to be the system default value. This value is only applied for the SYNC-NE AID on the ED-SYNCN command.
NONE
Set the SYNC_SRC value to the default value for BITS-OUT. This value only applies to the BITS-1 and BITS-2 AID of the ED-SYNCN command.
SYNC-NE
SYNC-NE source. It is only used in the alarm report or alarm retrieve commands.
27.29 SYNC_REF
Table 27-28 lists the synchronization reference (SYNC_REF) AIDs and their descriptions. The Facility AID formats for line timing are as follows:
•Format for optical facilities without PPM: FAC-[SLOT]-[PORT]
•Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]
Table 27-28 SYNC_REF
Pattern
Description
ALL
Equivalent to a combination of SYNC-ALL, BITS-1, and BITS-2. This AID is valid only for the commands RTRV-SYNCN, RTRV-ALM-SYNCN, and RTRV-COND-SYNCN.
SYNC-ALL
All synchronization references.
SYNC-{1-50}-NE
NE synchronization AID.
SYNC-{1-50}-{BITS1,BITS2}
BITS1 and BITS2 synchronization AIDs.
27.30 SYNCSW
Table 27-29 lists the synchronization switch (SYNCSW) AIDs and their descriptions.
Table 27-29 SYNCSW
Pattern
Description
INT
Internal clock. The "INT" value of the SYNCSW is only applied for the SYNC-NE AID on the OPR-SYNCSW command.
PRI
Primary timing reference.
SEC
Secondary timing reference.
27.31 UDC
Table 27-30 lists the user data channel (UDC) AIDs and their descriptions F-UDC and DCC-UDC channels on the AIC-I card.
Table 27-30 UDC
Pattern
Description
ALL
ALL AID is applicable to retrieve-only commands, for example: RTRV-ALM-UDCF, RTRV-COND-UDCF, RTRV-ALM-UDCDCC, and RTRV-COND-UDCDCC. It corresponds to a superset of F-UDC and DCC-UDC AIDs.
UDC-{F,DCC}-{A,B}
F-UDC and DCC-UDC AIDs for A and B channels.
27.32 VC
Table 27-31 lists the virtual channel (VC) AIDs and their descriptions for the NCS frame-level AID set. The VC4 AID formats are as follows:
VC4 for the STM4 card and VC4-4c for the STM4-4 card
VC4-{1-4,14-17}-{1-4}-{1-2}
VC4-3c for the STM4-4 card
VC4-{1-4,14-17}-{1-4}-{1-3}
VC4-2c for the STM4-4 card
VC4-{1-4,14-17}-{1-4}-{1-4}
VC4 for the STM4-4 card
VC4-{1-4,14-17}-{1-8}-1
VC4 for the STM1-8 card
VC4-{1-6,12-17}-1
VC4 for E1 card
VC4-{1-6,12-17}-1-1
VC4-4c for the STM-4 card. VC4-16c for the STM-16 card
VC4-{1-6,12-17}-1-{1,2,3,5,6,7,9,10,11,13,14,15}
VC4-2c for the STM-16 card
VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}
VC4-3c for the STM-16
VC4-{1-6,12-17}-1-{1,5,9,13}
VC4-4c for the STM-16 card
VC4-{1-6,12-17}-1-{1-16}
VC4 for the STM-16 card
VC4-{1-6,12-17}-1-{1-2}
VC4-3c for the STM-4 card
VC4-{1-6,12-17}-1-{1-3}
VC4-2c for the STM-4 card
VC4-{1-6,12-17}-1-{1-4}
VC4 for the STM-4 card
VC4-{1-6,12-17}-1-{1-9}
VC4-8c for the STM-16 card (454)
VC4-{1-6,12-17}-{1-4}
VC4 for DS3i-N-12, E3, G1000 cards
VC4-{1-6,12-17}-{1-4}-1
VC4 for STM-1 card
27.33 WDMANS
The WDMANS AID is used to access the automatic optical node setup (AONS) application of the NE. Table 27-32 lists the synchronization switch (SYNCSW) AIDs and their descriptions.
Table 27-32 WDMANS
Pattern
Description
WDMSIDE-{UNKNOWN,A,B,C,D,E,F,G,H}
Automatic MSTP node setup identifier
WDMNODE
Automatic MSTP node setup identifier
27.34 WLEN
This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line), the wavelengths contained are all the available wavelengths in the node (currently 32). If the facility is of type OCH (CHAN), the wavelength is the one correspondent wavelength customized for that channel. Table 27-33 lists the WLEN AIDs and their descriptions.