Guest

PowerVu Network Centre Management

Cisco PowerVu D9190 Conditional Access Manager Data Sheet

The Cisco PowerVu® D9190 Conditional Access Manager (PCAM) is one of the core components of the PowerVu next-generation system. The Cisco® D9190 is used for encrypting services with Cisco PowerVu Conditional Access (PCA), and is designed for use with the Cisco Digital Content Manager (DCM) to provide a functional replacement for the PowerVu D9140 Advanced Multiplexer.
For network monitoring and control, the Cisco D9190 (Figures 1 and 2) is integrated with Cisco PowerVu Network Centre (PNC).

Figure 1. Cisco PowerVu D9190 Conditional Access Manager

Figure 2. Cisco D9190 Rear Panel

Chassis Overview

The D9190 chassis features dual-redundant and hot-swappable power supplies. It has the capacity to hold up to six modules. The chassis supports advanced internal common synchronization mechanisms that can be used to synchronize the various services being hosted. Dedicated management and auxiliary input ports are also provided for control system monitoring and communication. The PowerVu Conditional Access (CA) modules are field-replaceable to allow for fast service with minimum downtime. A contact-closure output is used to signal a major alarm to the control system when it is active.

Cisco PCA

The PCA module is used to encrypt entitlement control message (ECM) and entitlement management message (EMM) traffic and to communicate with a DCM using various Simulcrypt protocols. The PCA module has four 1000BASE-T Ethernet ports, one of which is used to communicate with the DCM Multiplexer.

Features

• PCA encryption

• Dual-redundant, hot-swappable power supplies

• Support for one PCA module

• PNC management support

• Support for up to 85 services

• Simulcrypt communications support

Specifications

Table 1 lists specifications for the Cisco PowerVu D9190 Conditional Access Manager.

Table 1. Product Specifications

Feature

Description

Conditional Access

Brand

PowerVu CA

Crypto cycle

>= 1 sec

Services

85

Management

Control system

Integrated in PNC

Inputs/Outputs

Number of ports

Port 1 is for Simulcrypt communications

Ports 2, 3, and 4 are unused

Type

Eight-pin RJ-45, MDI

Ethernet type

100/1000BASE-T

Format

Simulcrypt protocols

Environment and Physical

Dimensions

1.73 in. H x 21.42 in. W x 17.36 in. D (4.4 cm H x 54.4 cm W x 44.1 cm D)

1U high, 19 in. rack-mountable, stackable

Operating temperature

32° to 122° F (0° to 50° C)

Storage temperature range

14° to 158° F (-10° to 70° C)

Weight

20.2 lb (9.2 kg)

Relative humidity

0 to 95%, noncondensing

Cooling

Forced cooling with air inlets on front panel, air exit at rear

Power Requirements

Voltage range

90 to 264 VAC input

Line frequency

47 to 63 Hz

Consumption

400W maximum (typical power consumption is 120W)

Regulatory Compliance Standards

CFR 47, Part 15, Subpart B Class A Unintentional Radiators

CISPR 22:2008-09

EN 55022:2006 +A1:2007, Class A - Information Technology Equipment

CISPR 24:1997 +A1:2001, +A2:2002

EN 55024:1998 +A1:2001, +A2:2003 EMC Requirements - Information Technology Equipment - Immunity Characteristics

IEC 61000-3-2:2005/EN 61000-3-2:2006 Harmonic Currents, Class A

IEC 61000-3-3:2002/EN 61000-3-3:1995' +A1:2001, +A2:2005 Flicker

Australia Radio Communications (Electromagnetic Compatibility) Standard 2008

CAN/CSA-C22.2 No. 60950-1-07

UL 60950-1 Ed. 2 Mar 27 2007

IEC 60950-1-am1 ed2.0 (2009-12), including all country and regional differences currently in force

EN 60950-1:2006+A1:2010

Ordering Information

Table 2 provides ordering information for the Cisco PowerVu D9190 Conditional Access Manager.

Table 2. Ordering Information

Chassis

Part Number

Chassis, D9190, 1RU (include 2AC power supply, software)

D9190-1RU

Chassis, D9190, 1RU, spare

CHAS-D9190-1RU=

Hardware Modules

Module, D9190, PCA card

D9190-PCA-K9

Module, D9190, PCA card, spare

D9190-PCA-K9=

Power Supply

PSU, D9036/D9190, AC, 400W, spare

D9036-PWR-400W-AC=

Accessories

Kit, D9036/D9190, fan replacement, 1RU, spare

D9036-FAN-1RU=

Kit, D9036/D9190, air filter, 1RU, spare

D9036D9190-DUST=

Service and Support

Using the Cisco Lifecycle Services approach, Cisco and its partners provide a broad portfolio of end-to-end services and support that can help increase your network's business value and return on investment. This approach defines the minimum set of activities needed by technology and by network complexity to help you successfully deploy and operate Cisco technologies and optimize their performance throughout the lifecycle of your network.

For More Information

To learn more about this product, contact your local account representative.
To subscribe to receive end-of-life/end-of-sale information, go to http://www.cisco.com/cisco/support/notifications.html.