The Prisma II optical network allows for best in class architectures with increased reliability, scalability, and cost-effectiveness. The High Density (HD) Erbium Doped Fiber Amplifier (EDFA) is designed to fit into a Prisma XD chassis or a standard full height Prisma II chassis (with the use of a host module). Up to two HD EDFA modules can be populated into a host module which requires a single service slot in the Prisma II chassis.
Figure 1. High Density EDFA
Features
• EDFA modules for optical amplification
• High density design allowing up to 16 EDFAs in a Prisma II XD chassis or up to 24 in a full height Prisma II chassis with redundant power supplies
• Energy-efficient design with low power consumption
• EDFA modules have both constant power and constant gain modes of operation
• Master/Slave redundancy using Controller Area Network with no external wiring needed
• Multiple setup and control options
– Local Control via Local Craft Interface (LCI)
– Local monitoring via Intelligent Communications Interface Module (ICIM)
– Remote monitoring via ROSA status monitoring and control element manager
High Density EDFA Modules
Table 1. High Density EDFA Specifications
Optical
Unit
EDFA
Gain-Flattened EDFA
Gain-Flattened EDFA, Variable Gain
Notes
17
dBm
20
dBm
22
dBm
17
dBm
20
dBm
17 dBm
20 dBm
21 dBm
Output Power (maximum)
dBm
17
20
22
17
20
17
20
21
1
Gain
dB
12
15
17
Low
High
Low
High
5 - 17
8 - 20
5 - 15
7
12
10
15
Input Power
dBm
0 to +10
-5 to
+10
-10 to
+5
-5 to
+10
-10 to
+5
-14 to +12
-14 to +12
-10 to +16
Input Wavelength
nm
1530 - 1565
1536 - 1562
1530 - 1562
1528 - 1562 for 17 dBm, 21 dBm
Output Power Stability
dB
± 0.3
± 0.4
± 0.4
Return Loss
dB
≥ 50 (exception for input port)
≥ 50
≥ 50
Polarization Sensitivity
dB
0.3
0.3
0.3
Noise Figure @ Input Power
dB
5.5 @ 0 dBm
6.5 @ 0 dBm
6.0 @ 0 dBm
6.0 @ 0 dBm
6.0 @ 5 dBm
Output Power Variation with Wavelength
dB
±0.2
N/A
N/A
Gain Flatness
dB
N/A
±0.75
±0.75
±1.0, for 17 dBm and 21dBm over 1528 - 1562 nm
2
Optical Interfaces
-
SC/APC (2)
SC/APC (2)
SC/APC (2)
Electrical
Power Consumption
W
7.5
7.5
9.0
7.5
7.5
7.5
9.0
9.0
Environmental
Operating Temp Range
Full Specs
Storage
°C
°F
°C
°F
-20 to +65
-4 to +149
-40 to +85
-40 to +185
Humidity Range
%
0 to 95
3
Mechanical
Length x Height x Width
in.
cm
8.8 x 3.48 x 1.03
22.35 x 8.84 x 2.62
Notes:
1. The output power is measured after a typical jumper loss of 0.2 dB.
2. Gain flatness measured under default gain conditions.
3. Non-condensing external to the Prisma II or XD chassis.
Ordering Information
The part numbers for the High Density EDFAs are shown below. Please consult with your Account Representative, Customer Service Representative, or Systems Engineer to determine the best configuration for your particular application.