The Cisco MDS SANTap feature provides CLI commands that support scripting and advanced operations.

This appendix contains a list of alphabetically arranged commands that are unique to Cisco MDS SANTap.

clear santap module

To clear SANTap information, use the clear santap module command.

clear santap module slot-number {avt avt-pwwn [lun avt-lun] | itl target-pwwn host-pwwn |
session session-id}

Syntax Description

slot-number

Specifies the Storage Services Module (SSM) module number. The range is 1 through 13.

avt avt-pwwn

Removes the appliance virtual target (AVT) pWWN. The format is hh:hh:hh:hh:hh:hh:hh:hh.

lun avt-lun

(Optional) Removes the appliance virtual target (AVT) LUN. The format is 0xhhhh[:hhhh[:hhhh[:hhhh]]].

itl target-pwwn host-pwwn

Removes the SANTap Initiator Target LUN (ITL) triplet. The format of the target-pwwn and the host-pwwn is hh:hh:hh:hh:hh:hh:hh:hh.

session session-id

Removes a session. The range for session ID is 0 through 2147483647.


Defaults

None.

Command Modes

EXEC mode.

Command History

Release
Modification

3.0(1)

This command was introduced.


Usage Guidelines

None.

Examples

The following example shows how to remove a SANTap session:

switch# clear santap module 13 session 2020

Related Commands

Command
Description

santap module

Configures the mapping between the Storage Services Module (SSM) and the VSAN where the appliance is configured.

show santap module

Displays the configuration and statistics of the SANTap feature.


clear ssm-nvram santap module

To clear the SANTap configuration for a specific slot stored on the supervisor flash, use the clear ssm-nvram santap module command in the configuration mode.

clear ssm-nvram santap module slot

Syntax Description

slot

Displays SANTap configuration for a module in the specified slot.


Defaults

None.

Command Modes

EXEC mode.

Command History

Release
Modification

3.2(1)

This command was introduced.


Usage Guidelines

None.

Examples

The following example shows how to clear the SANTap configuration for a slot 2:

switch# clear ssm-nvram santap module 2

Related Commandss

Command
Description

ssm enable feature

Enables the SANTap feature on the SSM.


santap module

To configure the mapping between the Storage Services Module (SSM) and the VSAN where the appliance is configured, use the santap module command in configuration mode. To disable this feature, use the no form of the command.

santap module slot-number {appl-vsan vsan-id [cvt-name cvt-name] |
dvt target-pwwn target-pwwn target-vsan target-vsan-id dvt-name dvt-name dvt-vsan dvt-vsan-id [dvt-port port-number] [lun-size-handling enable/disable] [io-timeout timeout-value]}

no santap module slot-number {appl-vsan vsan-id [cvt-name cvt-name] |
dvt target-pwwn target-pwwn}

Syntax Description

slot-number

Specifies the slot number of the SSM where the control virtual target (CVT) is created.

appl-vsan vsan-id

Specifies the appliance VSAN identification number used to communicate with the appliance. The range is 1 to 4093.

cvt-name cvt-name

(Optional) Specifies the control virtual target (CVT) name. The maximum size is 80 characters.

dvt

Configures the data virtual target (DVT).

target-pwwn target-pwwn

Specifies the target pWWN for the DVT. The format is hh:hh:hh:hh:hh:hh:hh:hh.

target-vsan target-vsan-id

Specifies the target VSAN for the DVT. The range for the real target-vsan-id is 1 through 4093.

dvt-name dvt-name

Specifies the DVT name. The maximum size is 80 characters.

dvt-vsan dvt-vsan-id

Specifies the DVT VSAN. The range for the dvt-vsan-id is 1 through 4093.

dvt-port port-number

(Optional) Specifies the DVT port. The range for the port number is 1 through 32.

lun-size-handling enable/disable

(Optional) Enables or disables LUN size handling. Specify 1 to enable or 0 to disable LUN size handling, with the default being enable.

io-timeout timeout-value

(Optional) Specifies the I/O timeout value. The range is 10 to 200 seconds, with the default being 10 seconds.


Defaults

Disabled.

The IO-timeout is 10 seconds.

Lun-size-handling is Enabled.

Command Modes

Configuration mode.

Command History

Release
Modification

2.1(1a)

This command was introduced.

3.0(1)

Added the following options: cvt-name, dvt, target-pwwn, target-vsan, dvt-name, dvt-vsan, dvt-port, lun-size-handling, and io-timeout.


Usage Guidelines

To access this command, you must first enable the SANTap feature on the SSM using the ssm enable feature command.

When the lun-size-handling option is set (enabled), the maximum logical block addressing (LBA) for DVT LUN is set to 2 TB. As a result, there is no issue with LUN resizing.


Note You can delete the dvt target-pwwn option using the no santap module slot dvt target-pwwn command. Other dvt options are not supported by the no form of the command.


Examples

The following example shows the configuration of the SSM where the SANTap feature is enabled and the VSAN used to communicate with the appliance:

switch# config terminal
Enter configuration commands, one per line.  End with CNTL/Z.
switch(config)# santap module 1 appl-vsan 1

Related Commands

Command
Description

show santap module

Displays the configuration and statistics of the SANTap feature.

ssm enable feature

Enables the SANTap feature on the SSM.


santap module dvt target

To configure SANTap target pWWN on a DVT, use the santap module dvt target-pwwn command in configuration mode.

santap module slot-number dvt target-pwwn target-pwwn target-vsan target-vsan-id dvt-name dvt-name dvt-vsan dvt-vsan-id [dvt-port port-number]

Syntax Description

slot-number

Specifies the slot number of the SSM where the control virtual target (CVT) is created.

dvt

Configures the data virtual target (DVT).

target-pwwn target-pwwn

Specifies the target pWWN for the DVT. The format is hh:hh:hh:hh:hh:hh:hh:hh.

target-vsan target-vsan-id

Specifies the target VSAN for the DVT. The range for the real target-vsan-id is 1 through 4093.

dvt-name dvt-name

Specifies the DVT name. The maximum size is 80 characters.

dvt-vsan dvt-vsan-id

Specifies the DVT VSAN. The range for the dvt-vsan-id is 1 through 4093.

dvt-port port-number

(Optional) Specifies the DVT port. The range for the port number is 1 through 32.


Defaults

None.

Command Modes

Configuration mode.

Command History

Release
Modification

2.1(1a)

This command was introduced.

3.0(1)

Added the following options: cvt-name, dvt, target-pwwn, target-vsan, dvt-name, dvt-vsan, and dvt-port


Usage Guidelines

To access this command, you must first enable the SANTap feature on the SSM using the ssm enable feature command.


Note You can delete dvt target-pwwn using the no santap module slot dvt target-pwwn command. Other dvt options are not supported by the no form of the command.


Examples

The following example shows how to configure SANTap target pwwn on a DVT:

switch# config terminal
Enter configuration commands, one per line.  End with CNTL/Z.
switch(config)# santap module 1 dvt target-pwwn 50:06:0e:80:03:81:32:36 taget-vs
an 9 dvt-name MYDVT dvt-vsan 12 dvt-port 1

Related Commands

Command
Description

show santap module

Displays the configuration and statistics of the SANTap feature.

ssm enable feature

Enables the SANTap feature on the SSM.


show santap module

To display the SANTap configuration on the Storage Services Module (SSM), use the show santap module command in EXEC mode.

show santap module slot {avt [name | brief] | avtlun | cvt [cvt-id | brief] | dvt [name | brief] | dvtlun | [name | brief] | session [session-id | brief] | tech-support}

Syntax Description

slot

Displays SANTap configuration for a module in the specified slot.

avt name

Displays the appliance virtual target (AVT) configuration.

(Optional) Specifies the user name.

brief

(Optional) Displays a brief format version of the display.

avtlun

Displays the appliance AVT LUN configuration.

cvt

Displays the control virtual target (CVT) configuration.

cvt-id

(Optional) Specifies a user configured CVT ID. The range is 1 to 65536.

dvt

Displays the data virtual target (DVT) configuration.

dvtlun

Displays the DVT LUN configuration.

session

Displays the SANTap session information.

session-id

(Optional) Specifies a user configured session ID. The range is 1 to 65536.

tech-support

Displays information for technical support.


Defaults

None.

Command Modes

EXEC mode.

Command History

Release
Modification

2.1(1a)

This command was introduced.

3.1(2)

Added the tech-support option.


Usage Guidelines

None.

Examples

The following example displays the SANTap AVT configuration:

switch# show santap module 2 avt

 AVT Information :
        avt pwwn     = 2a:4b:00:05:30:00:22:25
        avt nwwn     = 2a:60:00:05:30:00:22:25
        avt id       = 12
        avt vsan     = 4
        avt if_index = 0x1080000
        hi pwwn      = 21:00:00:e0:8b:07:61:aa
        tgt pwwn     = 22:00:00:20:37:88:20:ef
        tgt vsan     = 1

The following example displays the SANTap AVT LUN configuration:

switch# show santap module 2 avtlun

 AVT LUN Information :
        avt pwwn     = 2a:4b:00:05:30:00:22:25
        avt lun      = 0x0
        xmap id      = 16
        avt id       = 12
        tgt lun      = 0x0

The following example displays the SANTap CVT configuration:

switch# show santap module 2 cvt

 CVT Information :
        cvt pwwn     = 25:3c:00:05:30:00:22:25
        cvt nwwn     = 25:3d:00:05:30:00:22:25
        cvt id       = 1
        cvt xmap_id  = 2
        cvt vsan     = 10

The following example displays the SANTap DVT configuration:

switch# show santap module 2 dvt

 DVT Information :
        dvt pwwn     = 22:00:00:20:37:88:20:ef
        dvt nwwn     = 20:00:00:20:37:88:20:ef
        dvt id       = 3
        dvt mode     = 3
        dvt vsan     = 3
        dvt fp_port  = 0
        dvt if_index = 0x1080000
        dvt name     = MYDVT

The following example displays the SANTap DVTLUN configuration:

switch# show santap module 2 dvtlun

 DVT LUN Information :
        dvt pwwn     = 22:00:00:20:37:88:20:ef
        dvt lun      = 0x0
        xmap id      = 8
        dvt id       = 3
        dvt mode     = 0
        dvt vsan     = 3
        tgt pwwn     = 22:00:00:20:37:88:20:ef
        tgt lun      = 0x0
        tgt vsan     = 1

The following example displays the SANTap configuration session:

switch# show santap module 2 session

 Session Information :
        session id    = 1
        host pwwn     = 21:00:00:e0:8b:07:61:aa
        dvt pwwn      = 22:00:00:20:37:88:20:ef
        dvt lun       = 0x0
        tgt pwwn      = 00:00:00:00:00:00:00:00
        tgt lun       = 0x0
        adt pwwn      = 77:77:77:77:77:77:77:77
        adt lun       = 0x0
        num ranges    = 0
        dvt id        = 0
        vdisk id      = 0
        session state = 0
        mrl requested = 1
        pwl requested = 1
        iol requested = 0

The following example displays information for technical support:

switch# show santap module 4 tech-support

 DVT Information :
        dvt pwwn     = 22:00:00:20:37:39:b1:00
        dvt nwwn     = 20:00:00:20:37:39:b1:00
        dvt id       = 0x83fe924
        dvt mode     = 3
        dvt vsan     = 1
        dvt if_index = 0x1180000
        dvt fp_port  = 1
        dvt name     = MYDVT3
        dvt tgt-vsan = 2
        dvt io timeout            = 10 secs
        dvt lun size handling     = 1
        dvt app iofail behaviour  = 0
        dvt quiesce behavior      = 0
        dvt tgt iofail behavior   = 0
        dvt appio failover time   = 0 secs
        dvt inq data behavior     = 0

 DVT Information :
        dvt pwwn     = 22:00:00:20:37:88:20:ef
        dvt nwwn     = 20:00:00:20:37:88:20:ef
        dvt id       = 0x8405bbc
        dvt mode     = 3
        dvt vsan     = 1
        dvt if_index = 0x1186000
        dvt fp_port  = 7
        dvt name     = MYDVT3
        dvt tgt-vsan = 2
        dvt io timeout            = 10 secs
        dvt lun size handling     = 1
        dvt app iofail behaviour  = 0
        dvt quiesce behavior      = 0
        dvt tgt iofail behavior   = 0
        dvt appio failover time   = 0 secs
        dvt inq data behavior     = 0

 DVT Information :
        dvt pwwn     = 22:00:00:20:37:39:87:70
        dvt nwwn     = 20:00:00:20:37:39:87:70
        dvt id       = 0x8405b2c
        dvt mode     = 3
        dvt vsan     = 3
        dvt if_index = 0x118c000
        dvt fp_port  = 13
        dvt name     = MYDVT3
        dvt tgt-vsan = 2
        dvt io timeout            = 10 secs
        dvt lun size handling     = 1
        dvt app iofail behaviour  = 0
        dvt quiesce behavior      = 0
        dvt tgt iofail behavior   = 0
        dvt appio failover time   = 0 secs
        dvt inq data behavior     = 0

 CVT Information :
        cvt pwwn     = 29:5d:33:33:33:33:33:36
        cvt nwwn     = 29:5e:33:33:33:33:33:36
        cvt id       = 0x83b11e4
        cvt xmap_id  = 0x83b1204
        cvt vsan     = 2
        cvt name     =

---------------------------------------------------------------------
VSAN                 USAGE COUNT
---------------------------------------------------------------------
2                    4
switch#

Table A-1 describes the significant fields shown in the previous displays.

Table A-1 show santap Field Descriptions 

Field
Description

app lun

Displays the appliance LUN.

app pwwn

Displays the appliance port world wide name.

app vsan

Displays the appliance VSAN number.

avt id

Displays the AVT ID number.

avt if_index

Displays the AVT interface index number.

avt lun

Displays the AVT LUN.

avt nwwn

Displays the AVT node port world wide name.

avt pwwn

Displays the AVT port world wide name

avt vsan

Displays the AVT VSAN number.

cvt id

Displays the CVT ID number.

cvt nwwn

Displays the CVT node port world wide name.

cvt pwwn

Displays the CVT port world wide name

cvt vsan

Displays the CVT VSAN number.

cvt xmap_id

Displays the CVT Xmap ID number.

dvt fp_port

Displays the DVT fabric port number.

dvt id

Displays the DVT.

dvt if_index

Displays the DVT interface index number.

dvt lun

Displays the DVT LUN.

dvt mode

Displays the DVT mode.

dvt name

Displays the DVT name.

dvt nwwn

Displays the DVT node port world wide name.

dvt pwwn

Displays the DVT port world wide name.

dvt vsan

Displays the DVT VSAN number.

host pwwn

Displays the host port world wide name.

num ranges

Displays the number ranges.

session id

Displays the session ID number.

session state

Displays the session state.

tgt lun

Displays the target LUN.

tgt pwwn

Displays the target port world wide name.

tgt vsan

Displays the target VSAN number.

vdisk id

Displays the virtual disk ID number.

xmap id

Displays the Xmap ID number.


Related Commands

Command
Description

santap module

Configures the mapping between the SSM and the VSAN where the appliance is configured.


show santap module dvt brief

To display the SANTap Data Virtual Target (DVT) configuration in a brief format on the Storage Service Module (SSM), use the show santap module dvt brief command in the EXEC mode.

show santap module dvt brief slot

Syntax Description

slot

Displays SANTap configuration for a module in the specified slot.


Defaults

None.

Command Modes

EXEC mode.

Command History

Release
Modification

3.2(1)

This command was introduced.


Usage Guidelines

None.

Examples

The following example displays the SANTap module DVT brief infomation for slot 13:

switch# show santap module 13 dvt brief
-------------------------------------------------------------------------------
DVT WWN                 DVT ID               MD  DVT VSAN    DVTIFIDX
-------------------------------------------------------------------------------
50:06:0e:80:00:c3:e0:46 139639316            3   30          0x1604000 
switch# attach  module 13
Attaching to module 13 ...
To exit type 'exit', to abort type '$.' 
Bad terminal type: "xterm". Will assume vt100.

The following example displays the SANTap vttbl DVT configuration.

switch# attach module 2 
module-3# show santap vttbl dvt 50:00:1f:e1:50:0c:3b:09
DVT Entry  : 
        Activated        : FALSE
        Number LUNs     : 16
        Possible Hosts  : 
             hi_pwwn = 10:00:00:00:c9:3f:90:21 : 4 LUNs
             hi_pwwn = 10:00:00:00:c9:4c:c0:e5 : 2 LUNs
             hi_pwwn = 21:00:00:e0:8b:0c:7d:21 : 2 LUNs
             hi_pwwn = 10:00:00:00:c9:56:ed:f2 : 2 LUNs
             hi_pwwn = 50:06:0b:00:00:60:2a:a0 : 4 LUNs
             hi_pwwn = 21:00:00:e0:8b:92:62:92 : 2 LUNs

The following example displays the SANTap vttbl DVT host configuration:

switch# show santap vttbl dvt 50:00:1f:e1:50:0c:3b:09 host 10:00:00:00:c9:3f:90:21
HI-LIST Entry  : 
        State               : PRLI
        UA Power On         : 1
        FIT Created         : 1
        NVP Index           : 0x10000000c93f9021
    HI-LUNS Entry  : 
        Number of LUNs    : 4
        DVT ID              : 0x83f978c
        HI Index            : 0
        LUNs Installed      : TRUE
        Target Lun, DVT Lun pairs : 
        (0, 0)(1, 1)(2, 2)(3, 3)

Related Commands

Command
Description

show santap vttbl

Displays the SANTap VTTBL configuration.


show santap vttbl dvt

To display the host information logged into the Data Virtual Target (DVT) and the LUNs exposed to the hosts, use the show santap vttbl dvt command in the EXEC mode.

show santap vttbl dvt dvt_pwwn

Syntax Description

dvt_pwwn

Displays the pWWN information for DVT.


Defaults

None.

Command Modes

EXEC mode.

Command History

Release
Modification

3.2(1)

This command was introduced.


Usage Guidelines

None.

Examples

The following example displays the host information logged into the DVT:

module-2# show santap vttbl dvt 50:06:04:82:cc:ab:31:8c
    DVT Entry  : 
        Activated      : TRUE
        Number LUNs    : 96
        Possible Hosts : 
             hi_pwwn = 10:00:00:00:c9:63:a0:47  : 48 LUNs
             hi_pwwn = 10:00:00:00:c9:63:9f:b7  : 48 LUNs
             hi_pwwn = 10:00:00:00:c9:63:a1:cc  : 0 LUNs  
             hi_pwwn = 10:00:00:00:c9:63:a1:a6  : 0 LUNs

Related Commands

Command
Description

show santap vttbl

Displays the SANTap VTTBL configuration.

show santap vttbl dvt host

Displays the login status of the host on a DVT.


show santap vttbl dvt host

To display the login status of the host on a Data Virtual Target (DVT), use the show santap vttbl dvt host command in the EXEC mode.

show santap vttbl dvt dvt_pwwn host host_pwwn

Syntax Description

dvt_pwwn

Displays the pWWN information for DVT.

host_pwwn

Displays the pWWN information for host.


Defaults

None.

Command Modes

EXEC mode.

Command History

Release
Modification

3.2(1)

This command was introduced.


Usage Guidelines

None.

Examples

The following example displays the login status of the host on a DVT:

module-2# show santap vttbl dvt 50:06:01:60:41:e0:0a:3f host 21:00:00:e0:8b:9a:07:a3

    HI-LIST Entry  : 
        State          : PRLI
        UA Power On    : 1
        FIT Created    : 1
        NVP Index      : 0x210000e08b9a07a3
    HI-LUNS Entry  : 
        Number of LUNs : 21
        DVT ID         : 0x83f977c
        HI Index       : 5
        LUNs Installed : FALSE
        Target Lun, DVT Lun pairs : 
        (0, 1280)(1, 1281)(2, 1282)(3, 1283)(4, 1284)(5, 1285)(6, 1286)(7, 1287)
        (8, 1288)(9, 1289)(10, 1290)(11, 1291)(12, 1292)(13, 1293)(14, 1294)(15, 1295)
        (16, 1296)(17, 1297)(18, 1298)(19, 1299)(20, 1300)

Related Commands

Command
Description

show santap vttbl

Displays the SANTap VTTBL configuration.


ssm enable feature santap module

To enable SANTap on a particular module in a SSM, use the ssm enable feature santap module command in configuration mode. To disable this feature, use the no form of the command.

ssm enable feature santap module slot-number

no ssm enable feature santap module slot-number

Syntax Description

slot-number

Specifies the slot number of the SSM where SANTap is enabled.


Defaults

None.

Command Modes

Configuration mode.

Command History

Release
Modification

2.1(1a)

This command was introduced.


Usage Guidelines

None.

Examples

The following example shows the configuration of SANTap on an SSM:

switch# config terminal
Enter configuration commands, one per line.  End with CNTL/Z.
switch(config)# ssm enable feature santap module 1

Related Commands

Command
Description

no ssm enable feature

Disables the SANTap feature on the SSM.