Table Of Contents
About This Guide
Document Objectives
Audience
Document Organization
Document Conventions
Installation Warnings
Where to Find Safety and Warning Information
Obtaining Documentation and Submitting a Service Request
About This Guide
This preface includes the following sections:
•
Document Objectives
•
Audience
•
Document Organization
•
Document Conventions
•
Installation Warnings
•
Obtaining Documentation and Submitting a Service Request
Document Objectives
This guide describes how to perform installation and maintenance procedures on the Cisco ASA 5505 Adaptive Security Appliance.
Audience
This guide is for network administrators who perform any of the following tasks:
•
Managing network security
•
Installing and configuring firewalls
•
Managing default and static routes, and TCP and UDP services
Document Organization
This guide includes the following chapters and appendices:
•
Chapter 1, "Overview," describes the product overview, LEDs and memory requirements.
•
Chapter 2, "Preparing for Installation," describes the installation overview, safety recommendations, and general site requirements.
•
Chapter 3, "Installing the Cisco ASA 5505," describes how to connect the interface cables, and rack or wall mount the chassis .
•
Chapter 4, "Maintenance and Upgrade Procedures," describes the adaptive security appliance maintenance and upgrade procedures.
•
Appendix 1, "Cable Pinouts," describes the cable pinouts.
Document Conventions
Command descriptions use these conventions:
•
Braces ({ }) indicate a required choice.
•
Square brackets ([ ]) indicate optional elements.
•
Vertical bars (|) separate alternative, mutually exclusive elements.
•
Boldface indicates commands and keywords that are entered literally as shown.
•
Italics indicate arguments for which you supply values.
Examples use these conventions:
•
Examples depict screen displays and the command line in screen font.
•
Information you need to enter in examples is shown in boldface screen
font.
•
Variables for which you must supply a value are shown in italic screen font.
Graphical user interface examples uses these conventions:
•
Boldface indicates buttons and menu items.
•
Selecting a menu item (or pane) is indicated by the following convention:
Choose Start > Settings > Control Panel.
Note
Means reader take note. Notes contain helpful suggestions or references to material not covered in the manual.
Installation Warnings
Be sure to read the Regulatory Compliance and Safety Information for the Cisco ASA 5500 Series document that accompanied this device before installing the chassis. This document contains important safety information. This section includes the following warnings:
•
Power Supply Disconnection Warning
•
Jewelry Removal Warning
•
Wrist Strap Warning
•
Work During Lightning Activity Warning
•
Installation Instructions Warning
•
Chassis Warning for Rack-Mounting and Servicing
•
Short-Circuit Protection Warning
•
SELV Circuit Warning
•
Ground Conductor Warning
•
Blank Faceplates and Cover Panels Warning
•
Product Disposal Warning
•
Short-Circuit Protection Warning
•
Compliance with Local and National Electrical Codes Warning
•
DC Power Connection Warning
•
AC Power Disconnection Warning
•
TN Power Warning
•
48 VDC Power System
•
Multiple Power Cord
•
Circuit Breaker (15A) Warning
•
Grounded Equipment Warning
•
Safety Cover Requirement
•
Faceplates and Cover Panel Requirement
Power Supply Disconnection Warning
Warning
Before working on a chassis or working near power supplies, unplug the power cord on AC units; disconnect the power at the circuit breaker on DC units. Statement 12
Jewelry Removal Warning
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Statement 43
Wrist Strap Warning
Warning
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94
Work During Lightning Activity Warning
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001
Installation Instructions Warning
Warning
Read the installation instructions before connecting the system to the power source. Statement 1004
Chassis Warning for Rack-Mounting and Servicing
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: This unit should be mounted at the bottom of the rack if it is the only unit in the rack.When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006
Short-Circuit Protection Warning
Warning
This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045
SELV Circuit Warning
Warning
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Statement 1021
Ground Conductor Warning
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Blank Faceplates and Cover Panels Warning
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1029
Product Disposal Warning
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040
Short-Circuit Protection Warning
Warning
This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045
Compliance with Local and National Electrical Codes Warning
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
DC Power Connection Warning
Warning
After wiring the DC power supply, remove the tape from the circuit breaker switch handle and reinstate power by moving the handle of the circuit breaker to the ON position. Statement 8
AC Power Disconnection Warning
Warning
Before working on a chassis or working near power supplies, unplug the power cord on AC units. Statement 246
TN Power Warning
Warning
The device is designed to work with TN power systems. Statement 19
48 VDC Power System
Warning
The customer 48 volt power system must provide reinforced insulation between the primary AC power and the 48 VDC output. Statement 128
Multiple Power Cord
Warning
This unit has more than one power cord. To reduce the risk of electric shock when servicing a unit, disconnect the power cord of the power strip that the unit is plugged into. Statement 137
Circuit Breaker (15A) Warning
Warning
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors). Statement 13
Grounded Equipment Warning
Warning
This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use. Statement 39
Safety Cover Requirement
Warning
The safety cover is an integral part of the product. Do not operate the unit without the safety cover installed. Operating the unit without the cover in place will invalidate the safety approvals and pose a risk of fire and electrical hazards. Statement 117
Faceplates and Cover Panel Requirement
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 142
Where to Find Safety and Warning Information
For safety and warning information, see the Regulatory Compliance and Safety Information for the Cisco ASA 5500 Series document that accompanied the product. This document describes the international agency compliance and safety information for the Cisco ASA 5505 Adaptive Security Appliance. It also includes translations of the safety warnings.
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS Version 2.0.