March 15, 2007
NOTICE:
THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Products Affected
Products Affected |
Top Assembly |
Comments |
|
---|---|---|---|
Part Number |
Revision |
||
CRS-16-FC/M |
800-18561-05 |
C0 |
This rev board and future rev boards are all affected (can be rendered inoperable) if they are downgraded below the minimum ROMMON level. |
CRS-16-LCC-FAN-CT |
800-19837-07 |
E0 |
|
CRS-DRP-CPU |
800-19841-06 |
D0 |
|
CRS-FCC-SFC |
800-18562-09 |
E0 |
|
CRS-MSC |
800-25021-08 |
B0 |
|
CRS-16-ALARM |
800-19835-04 |
D0 |
|
CRS-16-FC/S |
800-18560-08 |
C0 |
|
CRS-FCC-LED |
800-19804-02 |
C0 |
|
CRS-8-FC/S |
800-23168-05 |
D0 |
Problem Description
Some CRS-1 boards have been manually downgraded in the field to a ROMMON level that was lower than the minumum required ROMMON level for that board. Manually downgrading below the minimum ROMMON level for a board will render the board inoperable, and it will need to be RMA'd.
Background
Boards which have shipped from Cisco (from Manufacturing or from the Depots) will have a ROMMON version that will either be at the minimum required level for that particular board, or it will be higher than the minimum required level.
There have been instances in customer networks where boards have been manually downgraded below the minimum required ROMMON level. Downgrading a board below the minimum ROMMON version for a given board, or version of a board, will render the board inoperable. Downgrading a board below the shipping ROMMON level will regress some fixes and enhancements.
If ROMMON is downgraded below the minimum version, field reprogramming will not be possible, and the board will need to be RMA'd.
Do not manually downgrade below the minimum ROMMON level on any CRS-1 boards as it will render the boards inoperable.
Problem Symptoms
Sample error messages after downgrading ROMMON below the minimum level on an MSC:
RP/0/RP1/CPU0:Jan 16 00:44:55.553 : exec[65760]: %MGBL-LIBPARSER-6-HIDDEN_COMMAND : This command has been deprecated: 'show ip interface brief ' RP/0/RP0/CPU0:Jan 16 00:48:23.154 : oir_daemon[273]: %PLATFORM-OIRD-5-OIRIN : OIR: Node 0/4/SP inserted RP/0/RP1/CPU0:Jan 16 00:48:38.000 : shelfmgr[314]: %PLATFORM-SHELFMGR-3-NO_PLIM : Can not power on node 0/4/SP due to absence of PLIM RP/0/RP1/CPU0:Jan 16 00:49:14.204 : oir_daemon[273]: %PLATFORM-OIRD-5-OIRIN : OIR: Node 0/PL4/SP inserted RP/0/RP1/CPU0:Jan 16 00:49:30.000 : shelfmgr[314]: %PLATFORM-MBIMGR-7-IMAGE_VALIDATED : 0/4/SP: MBI tftp:/disk0/hfr-os-mbi-3.2.3.CSCsd63325-1.0.0/sp/mbihfr-sp.vm validated RP/0/RP1/CPU0:Jan 16 00:50:39.506 : shelfmgr[314]: %PLATFORM-MBIMGR-7-IMAGE_VALIDATED : 0/4/CPU0: MBI tftp:/disk0/hfr-os-mbi-3.2.3.CSCsd63325-1.0.0/lc/mbihfr-lc.vm validated RP/0/RP1/CPU0:Jan 16 00:52:45.142 : shelfmgr[314]: %PLATFORM-MBIMGR-7-IMAGE_VALIDATED : 0/4/SP: MBI bootflash:mbis/hfr-os-mbi-3.2.3.CSCsd63325-1.0.0/012dee822d7af69ccbba2556bac04014/mbihfr-sp.vm validated SP/0/4/SP:Jan 16 00:52:54.936 : init[65541]: %OS-INIT-7-MBI_STARTED : total time 7.361 seconds SP/0/4/SP:Jan 16 00:53:07.298 : init[65541]: %OS-INIT-7-INSTALL_READY : total time 19.753 seconds SP/0/4/SP:Jan 16 00:56:41.790 : alphadisplay[100]: %PLATFORM-ALPHA_DISPLAY-6-CHANGE : Alpha display on node 0/4/SP changed to in state default SP/0/4/SP:Jan 16 00:56:49.167 : alphadisplay[100]: %PLATFORM-ALPHA_DISPLAY-6-CHANGE : Alpha display on node 0/4/SP changed to BRINGDOWN in state default
Workaround/Solution
Solution:
Do not manually downgrade below the minimum ROMMON level on any CRS-1 boards as it will render the boards inoperable.
Also, it is highly recommended that ROMMON levels aren't downgraded below the level that ships out from Cisco. There is a risk that downgrading ROMMON on a board will regress some fixes and enhancements.
RMA any boards which have been manually downgraded and rendered inoperable.
Use the following Failure Class and Failure Code in the RMA request form:
Failure Class: Administrative Request Failure
Code: Field Notice Alert
Use the following Table to identify minimum ROMMON levels: CRS-1 Software/Firmware Compatibility Matrix.
Note: This table also lists the recommended minimum ROMMON level to upgrade to (for boards and for IOS-XR Releases).
Revision History
Revision |
Date |
Comment |
---|---|---|
1.0 |
15-MAR-2007 |
Initial Public Release |
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.