March 16, 2006
NOTICE:
THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Products Affected
SCE SCAS BB - 3.0.0
Problem Description
Link failure-reflection and connection-mode configurations under LineCard interface configuration are not saved correctly to the startup-config and/or presented correctly in the running-config.
Non-default lines are not read into the running config. The system is otherwise unaffected.
The problem occurs only if the failure-reflection or connection-mode configuration parameters are different from the default setting.
Background
The startup-config is a text file that includes all the non-default configurations to be applied after the SCE reloads. It is created upon execution of the CLI command and/or after applying the Service Configuration (PQB) file. Due to a bug in the procedure that creates the configuration file, the two lines that should include the link failure-reflection and connection-mode configuration, if their state is not the default, are incorrectly written to the configuration file.
The same procedure is used also to display the running-config, so this problem applies to the running-config as well.
Problem Symptoms
The startup configuration and the running configuration include the following lines:
interface LineCard 0 on-all-portsconnection-mode inline
When the SCE executes the startup-config, after reload, these lines fail to run and the default configuration of link failure-reflection and connection-mode are applied.
Workaround/Solution
Manually edit the /tffs0/system/p3hidden/config/genstart.txt file. If it does not already exist, create it. See Note 1.
Add the configuration you wish to be applied after the SCE reloads. Since the link failure-reflection and connection-mode are part of the LineCard interface configuration, you must add the line before these commands.
For example:
LineCard interface 0 link failure-reflection on-all-ports connection-mode inline
Note 1 - File Creation Instructions
-
Copy from the SCE or create a file with the name genstart.txt
-
Edit the file and add the configuration lines that are non default.
For example:
interface LineCard 0 link failure-reflection on-all-ports connection-mode inline
-
Copy the file to the SCE /tffs0/system/p3hidden/config/genstart.txt
DDTS
To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.
DDTS |
Description |
---|---|
CSCsd36257 (registered customers only) |
link reflection & connection mode configurations aren't saved correctly |
Revision History
Revision |
Date |
Comment |
---|---|---|
1.0 |
16-MAR-2006 |
Initial Public Release |