White Paper
Strategic Directions Moving the Decimal Point:
An Introduction to 10 Gigabit Ethernet
10 Gigabit Ethernet was formally ratified as an IEEE 802.3 Ethernet standard in June 2002. This technology is the next step for scaling the performance and functionality of enterprise and service provider networks because it combines multigigabit bandwidth and intelligent services in order to achieve scaled, intelligent, multigigabit networks with network links that range in speed from 10 Mbps to 10,000 Mbps. Since March 1999 the Ethernet industry has been working on increasing the speed of Ethernet from one to ten gigabits per second. This technology is very significant because not only will Ethernet run at 10 Gigabits per second and serve as a local-area network (LAN) connection, but it will also work in metropolitan-area networks (MANs) and wide-area networks (WANs). With 10 Gigabit Ethernet, network managers will be able to build LANs, MANs, and WANs using Ethernet as the end-to-end Layer 2 transport.
Introduction
Managers of enterprise and service provider networks have many choices when they design networks. They have multiple media, technologies, and interfaces to choose from to build campus and metro connections, including OC-12 (622 Mbps), OC-48 (2.488 Mbps), synchronous optical network (SONET) and its European and international equivalent, synchronous digital hierarchy (SDH), packet over SONET (POS), dynamic packet transport (DPT), and resilient packet ring (RPR). With this new Ethernet technology, bandwidth can be scaled from one to ten gigabits per second without sacrificing any of the intelligent network services such as multiprotocol label switching (MPLS), Layer 3 switching, quality of service (QoS), caching, server load balancing, security, and policy-based networking. These services can be delivered at 10 Gbps line rates over the Ethernet network and supported over all network physical infrastructures in the LAN, MAN, and WAN.
10 Gigabit Ethernet is Ethernet. 10 Gigabit Ethernet uses the IEEE 802.3 Ethernet media access control (MAC) protocol, the IEEE 802.3 Ethernet frame format, and the IEEE 802.3 frame size. 10 Gigabit Ethernet is full duplex, just like full-duplex Fast Ethernet and Gigabit Ethernet; therefore, it has no inherent distance limitations. Because 10 Gigabit Ethernet is still Ethernet, it minimizes the IT manager's learning curve by maintaining the same management tools and architecture.
The IEEE 802.3ae 10 Gigabit Ethernet Task Force was chartered with developing the 10 Gigabit Ethernet Standard. This group is a subcommittee of the larger 802.3 Ethernet Working Group. In contrast to previous Ethernet standards, 10 Gigabit Ethernet targets three application spaces: the LANs, MANs, and WANs.
Cisco began shipping 10 Gigabit Ethernet products to customers in 2001 and by mid 2002 was shipping standards-compliant 10 Gigabit Ethernet interfaces on multiple products including the Cisco Catalayst 6500 and the Cisco 12000.
This white paper presents an overview of 10 Gigabit Ethernet technology and communicates Cisco's strategic direction regarding IEEE 802.3ae Ethernet by addressing the following topics:
•
Technology and application trends
•
10 Gigabit Ethernet and other higher-layer services
•
Expected LAN applications
•
Expected MAN applications
•
Expected WAN access applications
•
10 Gigabit Ethernet technology and standard
•
Goals of the IEEE 802.3ae Task Force
•
Optical transceivers and media supported
•
Fiber infrastructure issues
•
Recommendations for new fiber installation
Technology and Application Trends
The last incarnation of Ethernet, 1000BASE-T, extended Gigabit Ethernet operation over the installed Category 5 copper infrastructure and delivered Gigabit bandwidth and intelligence to enterprise and service provider data centers and server farms. The newest version of Ethernet, 10 Gigabit Ethernet, moves the decimal point from one to ten gigabits per second, enabling Ethernet to match the speed of the fastest technology on the WAN backbone, OC-192, which runs at approximately 9.5 Gbps.
The compelling reasons to develop 10 Gigabit Ethernet technology (also known as 10GBASE-X) are that it achieves the following:
•
Supports all services (packetized voice and video, data) and Layer 3 through Layer 7 intelligence
•
Easily scales enterprise and service provider networks
•
Leverages the 300 million plus installed base of Ethernet switch ports
•
Supports LANs, MANs, and WANs
•
Matches the MAN/WAN backbone speed of OC-192
Not only does 10 Gigabit Ethernet match the data rate of SDH or SONET OC-192, but the IEEE 802.3ae 10 Gigabit Ethernet Task Force has specified an optional interface that delivers Ethernet data at a rate compatible with SONET/SDH. This WAN physical layer (PHY) interface enables the attachment of packet-based IP/Ethernet switches to SONET/SDH access equipment.
Support for All Other Services
Because 10 Gigabit Ethernet is Ethernet and requires no change to the Ethernet media access control (MAC) protocol or packet format, 10 Gigabit Ethernet supports all upper-layer services. These include all of the Cisco Intelligent Network Services that operate at Layer 2 and Layer 3 and higher of the OSI seven-layer model: high availability, MPLS, QoS including voice-over-IP (VoIP) services, security and policy enforcement, server load balancing (SLB) and Web caching. 10 Gigabit Ethernet will also support all standard Layer 2 functions: 802.1p, 802.1Q VLANS, EtherChannel, and spanning tree.
Simple to Scale
Because almost all network traffic today starts out as Ethernet and Internet Protocol (IP) traffic, building Ethernet networks with the next step up in speed will be the easiest way to scale enterprise and service-provider networks. A fundamental rule of building switched networks is that a faster technology is always needed to aggregate multiple, lower-speed segments. As the density and the number of 100-Mbps segments at the edge of the network increase, 1000BASE-X and 1000BASE-T will become the uplink technology from the wiring closet to the core of the network. At the close of 2000, the Ethernet industry is shipping over 250 thousand Gigabit ports a month. 10 Gigabit is needed to aggregate these Gigabit segments.
In short, for enterprise LAN applications, 10 Gigabit Ethernet will enable network managers to scale their Ethernet networks from 10 Mbps, 100 Mbps, or 1000 Mbps to 10,000 Mbps, while leveraging their investments in Ethernet as they increase their network performance. For service provider metropolitan and wide-area applications, 10 Gigabit Ethernet will provide high-performance, cost-effective links that are easily managed with Ethernet tools.
Leverages the Installed Base of Ethernet: 10/100/10000
Over 300 million switched Ethernet ports have been installed worldwide. The development of 10 Gigabit Ethernet will not only enable network managers to take advantage of their investments in the installed equipment, network management and analysis tools, and IT staff expertise, it will also enable the Ethernet industry to take advantage of merchant silicon and optical components.
10 Gigabit Ethernet will be a cost-effective means of building 10-Gbps links. The reasons for this are two-fold. First, there is the design philosophy of the Ethernet industry, which assumes high-volume manufacturing and low-cost design. In fact, the Task Force adopted as a design goal the objective to develop 10 Gigabit Ethernet interfaces that would offer ten times the performance at three to four times the cost of the previous generation of Ethernet.
Second, because the whole industry, from chipset vendors and optical components manufacturers up the value chain to systems vendors, participates in the standards process, the 802.3 Ethernet interfaces are very well defined and can be implemented with available technology. This process enables intense market competition at every stage of the value chain, which lowers the costs of components and subsystems and lowers the costs of the systems that are available to the IT managers who are the final end customers. This process also means that most of the complexity of the encoding schemes and electronic circuitry becomes embedded in merchant silicon, which lowers costs and increases competition among vendors. The contribution of Ethernet to technical innovation, competition, and increasingly lower costs to final end users is evident in the traditional Ethernet cost curves witnessed with Ethernet, Fast Ethernet, and, most recently, Gigabit Ethernet. Finally, in contrast to a 10-Gbps telecommunications laser, 10 Gigabit Ethernet short links (less than 40 km on single-mode fiber) will use low-cost, uncooled optics and, in the future, vertical cavity surface emitting lasers (VCSELs), which are very low cost.
Network Applications of 10 Gigabit Ethernet
LAN Applications
10 Gigabit Ethernet has many potential applications for both service provider and enterprise networks. Figure 1 shows the standard LAN applications for 10 Gigabit Ethernet, which include the following:
•
Server interconnect for clusters of servers
•
Aggregation of multiple 1000BASE-X or 1000BASE-T segments into 10 Gigabit Ethernet downlinks
•
Switch-to-switch links for very high-speed connections between switches in the same data center, in an enterprise backbone, or in different buildings
The building cabling media supported for LAN applications will be single-mode fiber, FDDI-grade multimode fiber, and the new, higher-bandwidth (2000 MHz*km) multimode fiber.
Figure 1
10 Gigabit in the LAN
10 Gigabit Ethernet is used to link the core switches in both Campus A and Campus B. In fact, a primary use of 10 Gigabit Ethernet in the LAN will be to aggregate multiple Gigabit Ethernet segments. By 2003, the Dell`Oro Group forecasts shipments of 24 million Gigabit Ethernet ports. Most of these Gigabit ports will require 10 Gigabit Ethernet as an aggregation technology.
Many LAN customers expect to need 10 Gbps bandwidth soon. For example, network planners at Lawrence Berkeley National Laboratory have estimated their network bandwidth needs for 2001 to range between 5 and 40 Gbps. The applications expected to drive this demand for bandwidth include computations, real-time steering, remote visualization, and remote I/O. (M. Bennett, "A User's Perspective for Ten Gigabit Ethernet," Presentation to IEEE 802.3 Higher Speed Study Group, June 1, 1999.)
10 Gigabit Ethernet will be used in service provider and enterprise data centers and LANs. Initially, network managers will use 10 Gigabit Ethernet to provide high-speed interconnection between large-capacity switches inside the data center or computer room, or between buildings. As the need for bandwidth increases, 10 Gigabit Ethernet will be deployed throughout the entire LAN, including switch to server and MAN and WAN access applications.
MAN Applications
Dark Fiber Metro Applications
One of the most exciting innovations in the Gigabit space has been the growth in the deployment of long distance Gigabit Ethernet using long wavelength optics (1000BASE-LX and 1000BASE-ZX) on dark fiber to build network links that reach metropolitan distances. Cisco led the way with long distance Gigabit Ethernet, helping customers to build links ranging up to 100 kilometers with the use of pluggable transceivers called gigabit interface converters or GBICs.
10 Gigabit Ethernet will be deployed in MAN applications over dark fiber, over dark wavelengths, and as a fundamental transport for facility services. The term dark fiber refers to unused single-mode fiber capacity from fiber that has been installed for long distance applications that usually reach up to 100 kilometers without amplifiers or optical repeaters. This fiber is not currently "lit," meaning that it is not carrying traffic and is not terminated.
Service provider and local exchange carriers (LECs) are evaluating the use of 10 Gigabit Ethernet as the backbone technology to build out highly cost-effective, large-scale Layer 2 and Layer 3 infrastructures over which a service could be delivered to customers.
It is important to point out that the use of the term MAN in this context refers to the type of distances reached by the whole network and the type of service delivered to the customer. The actual physical and logical topology is that of a very large LAN because the facility provider is not building a traditional SONET/ATM MAN, but instead is using 10 Gigabit Ethernet to build point-to-point links between Layer 3 through 4 switches. TCP/IP or other services can be delivered over the Ethernet network.
Figure 2
10 Gigabit Ethernet Metropolitan Network
As shown in Figure 2, 10 Gigabit Ethernet metropolitan networks will enable service providers to reduce the cost and complexity of their networks while increasing backbone capacity to 10 Gbps by eliminating the need to build out an infrastructure that contains not only several network elements required to run TCP/IP and data traffic but also the network elements and protocols originally designed to transport voice. Reduction in the number of network elements and network layers lowers equipment costs, lowers operational costs, and simplifies the network architecture. With 10 Gigabit Ethernet backbone networks, service providers will be able to offer native 10/100/1000 Mbps Ethernet as a public service to customers, namely offering the customer twice the bandwidth of the fastest public MAN services OC-3 (155 Mbps) or OC-12 (622 Mbps) with no need for the added complexity of SONET or ATM and no need for protocol conversion.
Dark Wavelength Metro Applications with DWDM
As Figure 3 shows, 10 Gigabit Ethernet will be a natural fit with dense wave division multiplexing (DWDM) equipment as more of the latter is deployed in metropolitan applications. For enterprises, access to 10 Gigabit Ethernet services over DWDM will enable serverless buildings, remote backup, and disaster recovery. For service providers, 10 Gigabit Ethernet in the MAN will enable the provisioning of dark wavelength gigabit services at very competitive costs.
Figure 3
10 Gigabit Ethernet in the MAN over DWDM
The term dark wavelength or dark lambda refers to unused capacity available on a DWDM system. WDM is a long established technology in the WAN backbone that enables multiple data streams to be transformed into multiple independent wavelengths. DWDM refers to systems that apply the tight wavelength spacing specified by the International Telecommunications Union (ITU), which is normally less than a nanometer (nm). Coarse or wide wavelength division multiplexing (CWDM) refers to much cheaper systems that use wider spacing between wavelengths, which is normally about 10 nm. The WDM device then multiplexes the multiple (16, 32, and 64) streams into one stream of "white light" across one fiber pair, increasing the bandwidth capacity of the link by 16-, 32-, or 64. At the opposite end, the multiple wavelengths are demultiplexed into the original data streams. Many MANs and much of the WAN backbone today contain installed DWDM equipment that has unused capacity or dark wavelengths.
10 Gigabit Ethernet WAN Applications
WAN applications for 10 Gigabit Ethernet look very similar to MAN applications: Dark fiber, dark wavelength, and support for SONET infrastructure. Figure 4 shows multilayer switches and terabit routers attaching via 10 Gigabit Ethernet to the SONET optical network, which includes add drop multiplexers (ADMs) and DWDM devices. When dark wavelengths are available, 10 Gigabit Ethernet can be transmitted directly across the optical infrastructure reaching distances from 70 to 100 km.
SONET is the dominant transport protocol in the WAN backbone today and most MAN public services are offered as SONET OC-3 (155 Mbps) or OC-12 (622 Mbps).
Figure 4
10 Gigabit Ethernet in the WAN
Because most of today's installed optical infrastructure is built out with a specific architecture and specific timing requirements to support OC-192 SONET, the IEEE 802.3ae Task Force specified an Ethernet interface that attaches to the SONET-based TDM access equipment at a data rate compatible with the payload rate of OC-192c/SDH VC-4-64c. This is accomplished by means of a physical layer link based on the WAN PHY between Gigabit or Terabit switches and Ethernet line-terminating equipment (LTE) which is attached to the SONET network. The WAN PHY interface does not attach directly to a SONET OC-192 interface. This WAN PHY interface will allow the construction of MANs and WANs that connect geographically dispersed LANs between campuses or POPs through the SONET transport network. In other words, 10 Gigabit Ethernet interfaces that are compatible with SONET OC-192 payload rate facilitate the transport of native Ethernet packets across the WAN transport network with no need for protocol conversion at Layer 3 at the WAN edge. The conversion or encapsulation happens at Layer 1 in the PHY.
As stated above, reducing the need for protocol conversion increases the performance of the network and makes it simpler, easier to manage, and less costly because protocol conversion is CPU-intensive and adds complexity and additional elements to the network. Figure 4 shows that this WAN PHY interface will enable Internet service providers (ISPs) and network service providers (NSPs) to create very high-speed links at very low cost between co-located, carrier-class switches and routers. Note that in certain applications, this WAN PHY link might well be less than 300 meters.
The flexibility, compatibility, and simplicity of 10 Gigabit Ethernet cannot be overemphasized. It will be deployed in LANs and MANs. It will be used with OC-48 and OC-192. It will also be used over dark fiber without OC-192 or SONET.
10 Gigabit Ethernet: Technology and Standard
The Ubiquity of Ethernet
Without question, 10/100/1000 Mbps Ethernet is the world's most ubiquitous networking technology. Over 90 percent of today's network-attached desktops are attached with Ethernet. Since 1985, over 300 million 10, 100, and 1000 Mbps Ethernet ports have shipped with a market value exceeding billions of U.S. dollars. Once volume shipments begin to ramp, 10 Gigabit Ethernet interfaces are expected to be a very cost-effective means of deploying 10-Gbps bandwidth. The ubiquity of Ethernet makes it easy to find human and other resources to manage Ethernet networks. Because 10 Gigabit Ethernet is still Ethernet, it minimizes the IT manager's learning curve by maintaining the same management tools and architecture.
10 Gigabit Ethernet is the next stage in the natural evolution of Ethernet. All Gigabit Ethernet ports shipped today are full duplex and switched; Gigabit Ethernet is no longer a shared domain, half-duplex technology. 10 Gigabit Ethernet will also be a full-duplex, switched technology, maintaining compatibility with the 802.3 Ethernet MAC protocol and the Ethernet frame format.
Roles of the IEEE 802.3ae Task Force and 10 Gigabit Ethernet Alliance
In March 1999, representatives from Cisco Systems helped start the IEEE 802.3 10 Gigabit Ethernet standards effort by participating in the creation of a study group called the Higher Speed Study Group (HSSG). This study group concluded its work in November 1999 and in February 2000 became the IEEE 802.3ae 10 Gigabit Ethernet Task Force. When the IEEE 802.3ae document was ratified as a formal Standard in June 2002, the Task Force had accomplished its goals and ceased work. In February 2000, Cisco cofounded with six other companies the 10 Gigabit Ethernet Alliance (10GEA), an industry consortium with three primary aims:
•
Promote industry awareness, acceptance, and advancement of the 10 Gigabit Ethernet standard
•
Provide a forum for technical discussion and provide technical contributions to the IEEE 802.3ae Task Force; thus accelerating the standards effort
•
Provide resources to establish and demonstrate multivendor interoperability of 10 Gigabit Ethernet products
The IEEE 802.3 Working Group, with its subcommittees such as the IEEE 802.3ae Task Force, is a standards body where individuals not companies participate and vote. In comparison, the Alliance is an industry consortium whose membership consists of companies. The Alliance does not write the standard, but supports the IEEE 802.3 standards effort. Cisco helps lead the activities of the Alliance by serving on the Alliance Board of Directors. A representative from Cisco is currently Vice President of the Alliance. By September 2000, membership of the 10 GEA reached over 80 members including all the major networking and telecommunications equipment vendors and many startup companies.
Scope of the Standards Effort
Like all previous Ethernet technologies, 10 Gigabit Ethernet is a layered protocol (see Figure 5). The standard will define protocols and interfaces at and below the MAC layer, including additions to the MAC layer, management objects, and encoding schemes for transmission and signaling over supported media. This means that the scope of the Task Force's work includes defining 10 Gigabit Ethernet at Layer 2, and at Layer 1 defining the physical layer devices (PHYs) and defining the optical transceivers or PMDs.
IEEE 802.3 Task Forces always define the scope of their work by defining formal objectives. The objectives of the 802.3ae Task Force included the following:
•
Preserve the 802.3 Ethernet frame format at the MAC client service interface
•
Preserve the minimum and maximum frame size of the current IEEE 802.3 Standard
•
Support full-duplex operation only
•
Support star-wired LANs using point-to-point and structured cabling topologies
•
Specify an optional media-independent interface
•
Support the IEEE 802.3ad standard for link aggregation
•
Support a speed of 10.000 Gbps at the service interface between the MAC and the physical layer signaling sublayer (PLS)
•
Define two families of physical layers (PHYs):
–
A LAN PHY operating at a data rate of 10.000 Gbps
–
A WAN PHY operating at a data rate compatible with the payload rate of OC-192c/SDH VC-4-64c
•
Define a mechanism to adapt the MAC/PLS data rate to the data rate of the WAN PHY
•
Support fiber media selected from the second edition of the international and European building wiring standards, ISO/IEC 11801
Figure 5
10 Gigabit Ethernet Layered Protocol
In terms of the classical OSI layer model, Ethernet is a Layer 2 protocol. Just like previous generations of Ethernet such as 1000BASE-X and 1000BASE-T remained Ethernet, 10 Gigabit Ethernet remains Ethernet. 10 Gigabit Ethernet uses the IEEE 802.3 Ethernet MAC protocol and the same Ethernet frames as 10, 100, and 1000 Mbps Ethernet.
Although the IEEE 802.3 standard for Gigabit Ethernet supported both full and half duplex, customers selected only products that provided full-duplex operation. For this reason, the IEEE 802.3ae Task Force decided unanimously that 10 Gigabit Ethernet would be full duplex only. Because 10 Gigabit Ethernet is full duplex only, it is unlimited in reach. Only the physics of transmission and the physical media limit the distance of the link. In other words, because there are no packet collisions in a full-duplex link, the link distances are determined by optics and not by the diameter of an Ethernet collision domain.
Ethernet remains an asynchronous link protocol, so that timing or synchronization is maintained within each character in the bit stream of data and the receiving router, switch, or hub has the opportunity to retime the data and resynchronize at the beginning of the character. In contrast, each device in a SONET network must share the same clock in order to avoid timing drift between transmission and reception.
Layer 1: Physical Layer Devices
In order to address the LAN, MAN, and WAN applications, most of the work of the Task Force involved defining appropriate PHYs. The Ethernet PHY at Layer 1 of the OSI model connects the media to the MAC (Layer 2) and defines electrical and optical signaling, line states, clocking guidelines, data encoding, and circuitry needed for data transmission and reception. Contained within the PHY are several sublayers that perform these functions, including the physical coding sublayer (PCS) and the optical transceiver or physical media dependent (PMD) sublayer for fiber media. The PCS is made up of coding (for example, 8b/10b) and serializer or multiplexing functions.
The IEEE 802.3ae 10 Gigabit Ethernet Standard defines two PHY types: the LAN PHY and the WAN PHY. The latter is defined by the Standard as an optional WAN PHY that can interface with the existing WAN SONET infrastructure. The goal of the Task Force was to define a SONET-compatible PHY that will operate at a data rate that is compatible with the payload rate of OC-192c/SDH VC-4-64c. This SONET-friendly interface allows 10 Gigabit Ethernet switches and routers to attach to SONET access equipment and to use the SONET infrastructure for Layer 1 transport. The WAN PHY is simply an optional extended operating feature that is added to a LAN PHY. The WAN PHY interface is not SONET compliant or SONET compatible and it does not attach directly to a SONET interface. Finally, it should be pointed out that 10 Gigabit Ethernet PMDs are needed at both ends of the 10 Gigabit Ethernet link between the gigabit switch or router and the LTE (see Table 1).
Both the LAN and WAN PHY will support each physical medium-dependend (PMD) sublayer and, therefore, support the same distances. These PHYs are distinguished solely by the PCS. In other words, the LAN and WAN PHYs are distinguished solely by the PCS encoding sublayer and both will be able to use the same optical transceivers.
The WAN PHY differs from the LAN PHY by the inclusion of a simplified SONET framer. Because the line rate of SONET OC-192 is very close to 10 Gbps, it is simple to implement a MAC that can operate either with a LAN PHY at 10 Gbps or with a WAN PHY at the SONET OC-192 payload rate. To enable low-cost WAN PHY implementations, the Task Force specifically rejected conformance to SONET jitter, stratum clock, and other SONET optical specifications.
The WAN PHY is a PHY that does some SONET framing and supports the SONET/SDH payload rate of 9.58 Gbps. Early in the standards process, representatives from Cisco Systems proposed a unified PHY that would support both LAN and WAN applications by including the SONET framing functionality in a WAN interface sublayer (WIS). This solution has been instantiated by makers of chipsets that include both LAN and WAN PHY functions. Whether WAN PHY or unified PHY with the WIS enabled, such a PHY will most likely be used to build short links between collocated switches and routers and optical line terminating equipment (LTEs) that are attached to the SONET-based optical cloud (see Figure 6).
Figure 6
Use of the WAN PHY
To conclude the discussion of PHYs, 10 Gigabit defines a LAN PHY that, with simple encoding, will transmit Ethernet packets on dark fiber and dark wavelengths. The LAN PHY is intended to support the existing Ethernet applications at ten times the bandwidth with the most cost-effective solution. 10 Gigabit Ethernet also defines an optional WAN PHY that is used to attach data equipment, like switches or routers, to SONET/SDH access equipment. This allows the creation of Ethernet links that are extended over the SONET/SDH network. It is of course possible to build optical networks without SONET/SDH. Over time it is expected that the LAN PHY will be used in pure optical switching environments for MANs and WANs.
10 Gigabit Ethernet and Fiber Infrastructure Issues
Optical Transceivers (PMDs) and Supported Media
The 802.3ae Task Force investigated, in some detail, media and distance goals for 10 Gigabit Ethernet which are listed in Table 2.
Optical transceivers or PMDs are defined for specific media and distances. The PMD sublayer transforms the incoming bit stream of changing voltages into light pulses so that the data can be sent across the fiber optic media. The IEEE 802.3ae Task Force selected four optical transceivers:
•
1310 nm serial PMD to support at least 10 kilometers for single-mode fiber
•
1550 nm serial PMD to support at least 40 kilometers on single-mode fiber
•
850 nm serial PMD to support at least 65 meters on 500 MHz*km 50/125 micron multimode fiber
•
1310 nm CWDM PMD to support at least 300 meters on installed 160 MHz*km 62.5/125 micron multimode fiber (or better)
Support of the 40 km PMD is an acknowledgement that Gigabit Ethernet is already being successfully deployed in metropolitan and private, long-distance applications. The 1550 nm serial laser PMD reaches over 40 km and possibly up to 80 km over existing single-mode fiber. With such 10 Gigabit Ethernet technology, service providers will be able to build simple Ethernet networks with Layer 3 through Layer 4 switches over dark fiber without SONET or ATM and provision high-speed 10/100/1000 Mbps services at very low cost.
The 1310 nm serial PMD is likely to be the PMD of choice when building links to the optical SONET infrastructure.
The 1310 CWDM PMD, based on wavelength division multiplexing, supports installed multimode fiber backbones by transmitting, multiplexing, and demultiplexing upon reception four optical wavelengths across one 62.5/125 micron multimode fiber pair up to 300 meters. This PMD supports the installed base of 62.5/125 micron multimode fiber with 160/500 MHz*km bandwidth up to distances of 300 meters. This type of fiber is commonly known as FDDI-grade fiber. This PMD will also reach up to 10 km on single-mode fiber.
The Task Force identified the need to support low-cost, short-reach optics for 50/125 micron multimode fiber links reaching at least 65 meters for data centers and other short reach applications. The Task Force selected the 850 nm serial PMD for this application. See Table 3 for a summary of the optical transceivers and the media and distances supported.
1. 500 MHz*km is the OFL bandwidth value. Rated laser bandwidth might change when the TIA FO.2 work is complete2. CWDM: Coarse wavelength division multiplexing3. ANSI/TIA/EIA-568-A specifies that the nominal "mode field diameter" shall be 8.7 to 10.0 microns with a tolerance of +/- 0.5 micron at 1310 nm4. N.A. Not applicableTo summarize, the IEEE 802.3ae Task Force has selected four optical transceivers: 1310 nm serial for single-mode fiber, 1550 nm serial for single-mode fiber, 850 nm serial for 50/125 micron multimode fiber, 1310 nm coarse wide wavelength division multiplexing (CWDM) for installed 62.5/125 or FDDI-grade multimode fiber and single-mode fiber. The 802.3 Ethernet Working Group ratified the selection of these four PMDs and the refinement of the distance objectives.
IEEE 802. Port Type Names
The IEEE ascribes names called port types to each of the IEEE 802.3 interfaces. In the case of Gigabit Ethernet, three port types were developed and have found wide deployment in the market: 1000BASE-SX for short wavelength (850 nm lasers) and a PHY with 8B/10B encoding (X) on MM fiber, 1000BASE-LX for long wavelength 1310 nm lasers (L) and 8B/10B encoding on MM or SM fiber, and 1000BASE-T for 1000 Mbps operation over Category 5 (or T for twisted pair) cabling.
Since there are four PMDs and two PHYs, there should be eight 10 Gigabit Ethernet port types. Because there was no market demand for a WAN PHY with -LX4 CWDM optics, there are only seven 10 Gigabit Ethernet port types. See Figure 7 which shows the seven port types in the layer diagram. The port type names consist of a prefix, a base word, and a suffix. The 10 Gigabit prefix is 10G for which identifies the 10 Gbps data rate. The base word "BASE" is all uppercase and stands for baseband communications.
The suffix consist of three values. The first value indicates the wavelength of the laser: S, L, or E stand respectively for 850 nm short wavelength, 1310 nm long wavelength or 1550 nm extended wavelength. The second value indicates LAN or WAN PHY. W stand for WAN PHY, R for LAN PHY, and X is used for 8B/10B encoding. X is always a LAN PHY. The third value when present is a number, one (1) for serial or four (4) for CWDM using four wavelengths. When the port type is a serial PMD, the naming convention is to omit the number one. For example, 10GBASE-LR is 1310 serial laser plus a LAN PHY. 10GBASESW is 850 nm serial laser plus a WAN PHY.
Figure 7
10 GbE Port Types
Recommendations for Fiber Optic Media in New Installations
Various fiber optic and cabling vendors have been marketing 50-micron diameter multimode fiber cable products with enhanced bandwidth specifications. This fiber type recently became standardized. The second edition of the ISO 11801 (the European and International standard for building cabling) completed a ballot process that included the newer MM fibers. This document includes multimode fiber types with bandwidth specifications up to 2000 MHz*km. The Telecommunications Industry Association (TIA), the U.S. standards body for building cabling also finished a ballot process on these specifications as an Addendum to TIA/EIA-568-B.3, the Optical Fiber Cabling Components Standard. More important, the optical component and the fiber manufacturers completed work in the TIA Fiber Optic-2.2.1 Task Group on ways both to characterize the launch of lasers into this media and to measure the higher bandwidth. The IEEE 802.3ae 10 Gigabit Ethernet Standard includes support for the 2000 MHz*km 50 micron MM fiber with 10GBASE-S transceivers. To support the deployment of 10 Gigabit Ethernet, the best choice is to deploy single-mode fiber such as Corning SMF-28 or Mohawk/CDT TruLiteTM or equivalent. When support for legacy 100BASE-FX or 1000BASE-SX ports is required, customers should consider a hybrid single-mode and multimode product that contains as many pairs of single-mode fiber as possible. By use of such a product, network managers achieve backward compatibility with 100BASE-FX and backward compatibility with 1000BASE-SX ports, which are cheaper than 1000BASE-LX ports. Conventional 100BASE-FX uses light-emitting diodes (LEDs) and will not run on single-mode fiber.
It is worth noting that some Cisco customers have chosen to cable not only their networks but also their data centers completely with single-mode fiber. For building backbone distances over 300 meters, single-mode fiber will be the only specified solution. Although the termination and connectors as well as the optical transceivers (switch ports) for single-mode fiber are more expensive than for multimode fiber, it cannot be overemphasized that single-mode fiber is the only media that without exception will support not only 10 Gigabit Ethernet in 2001 and 2002, but also the next generation of Ethernet (100 Gbps) in 2006 and 2007.
The bottom line is that for fiber optic premises cabling inside the building, network managers and planners should deploy a hybrid single-mode and multimode product that contains as many pairs of single-mode fiber as possible, the multimode fiber for legacy support, and the mode for future multigigabit applications. Outside the building and for any link over 300 meters, single-mode fiber is the right choice.
Conclusion and Summary
To conclude, 10 Gigabit Ethernet might well become the technology of choice for enterprise, metropolitan, and wide-area networks. In terms of physical media, 10 Gigabit Ethernet will support distances to 300 meters on installed multimode fiber and over 40 km (or more) on single-mode fiber. With 10 Gigabit Ethernet, network managers will be able to build LANs, MANs, and WANs using Ethernet as the end-to-end Layer 2 transport. Long-distance reach on single-mode fiber enables network managers to build simple, low-cost metropolitan-sized networks with Layer 3 through Layer 4 switches and 10 Gigabit Ethernet backbones. In addition, 10 Gigabit Ethernet will support an optional SONET-friendly PHY to enable transmission of Ethernet over the SONET transport infrastructure.
Web References:
For IEEE presentations, meeting minutes, and tutorials that are in the public domain, refer to the following URL:
http://grouper.ieee.org/groups/802/3/ae/index.html
For an IT manager's perspective on 10 Gigabit Ethernet:
http://grouper.ieee.org/groups/802/3/10G_study/public/june99/bennett_1_0699.pdf
For general and technical information on 10 Gigabit Ethernet:
www.10gea.org
For information on cabling issues:
http://www.bicsi.com/
http://www.mohawk-cdt.com/main.html
Glossary
CWDM—Coarse wavelength division multiplexing. A relatively low-cost WDM technology that uses wide spacing (about 10 nm) between wavelengths and uncooled optics.
DWDM—Dense wavelength division multiplexing. A carrier-class WDM technology that uses expensive, cooled optics and tight spacing between wavelengths of less than a nanometer based on the specifications of the International Telecommunications Union (ITU) DWDM wavelength grid.
HSSG—Higher speed study group. The group commissioned by the IEEE 802.3 Ethernet working group with drafting the technical scope and objectives of the standards effort.
IEEE 802.3 Working Group: The permanent standing Ethernet committee of the IEEE 802 standards body.
IEEE 802.3ae Task Force: The group chartered by the IEEE 802.3 working group with writing the specification for 10 Gigabit Ethernet. IEEE 802.3ae is also the name of the document produced by the Task Force.
IEC/ISO 11801: The international and European standard for building cabling.
MAC: Media access control protocol.
PHY: Physical layer device. The Ethernet PHY at Layer 1 of the OSI model defines the electrical and optical signaling, line states, clocking guidelines, data encoding, and circuitry needed for data transmission and reception. Contained within the PHY are several sublayers that perform these functions including the physical coding sublayer (PCS) and the optical transceiver or physical media dependent (PMD) sublayer for fiber media. The Ethernet PHY connects the media to the MAC (Layer 2).
PAR: Project authorization request. The document drafted by the HSSG requesting that a standards effort be started.
PCS: Physical coding sublayer.
PMD: Physical media dependent sublayer, usually an optical transceiver.
TIA 568: The U.S. standard for building cabling.
VCSEL: Vertical cavity surface emitting laser. A laser technology based on the methods of semiconductor manufacturing and packaging that enable high-volume manufacturing, lower-cost, and greater efficiencies.
WAN PHY: The optional PHY that includes a simple SONET framer and operates at a data rate compatible with the payload rate of OC-192c/SDH VC-4-64c.
WDM: Wavelength division multiplexing: A means of data transmission that uses optical multiplexing to enable two or more wavelengths each with its own data source to share a common fiber optic medium.
WWDM: Wide wavelength division multiplexing. A relatively low-cost WDM technology that uses wide spacing and uncooled optics.
1. For the purposes of this white paper, SONET and SDH will be considered synonymous.