Guest

IBM Presentation Services

Session Switching with DLUR and DLUS Using Static Links and Dynamic PUs

Document ID: 12329

Updated: Sep 09, 2005

   Print

Introduction

This document provides a sample configuration for a Cisco TN3270 Server that is using session switching with a Dependent Logical Unit Requester (DLUR) and a Dependent Logical Unit Server (DLUS) that is using static links and dynamic Physical Units (PUs).

Prerequisites

Requirements

There are no specific requirements for this document.

Components Used

This document is not restricted to specific software and hardware versions.

The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.

Conventions

For more information on document conventions, refer to Cisco Technical Tips Conventions.

Configure

In this section, you are presented with the information to configure the features described in this document.

Note: To find additional information on the commands used in this document, use the Command Lookup Tool (registered customers only) .

Network Diagram

This document uses this network setup:

72-a.gif

Configuration

This is in place for this sample configuration:

  • Two Logical Partitions (LPARs) that are running Multiple Virtual Storage (MVS) in an Enterprise System Connection (ESCON) Multiple Image Facility (EMIF) mainframe:

    • LPAR #1: MVS1 System. This system should be configured as a Network Node (NN) only.

    • LPAR #2: MVS2 System. This system should be configured as an NN and a primary DLUS.

  • No Advanced Peer-to-Peer Networking (APPN) subsystem on the Router, except for the Cisco TN3270 Server DLUR, which is used as an end node.

  • The Cisco TN3270 Server Listening IP address 172.26.19.99 connected to the DLUS (MVS2).

  • Static links configured under the Cisco TN3270 Server DLUR for connection to the MVS1 and MVS2.

  • MVS1 connected to MVS2 through the Channel To Channel (CTC) link.

  • Control Point to Control Point (CP-CP) Connection established between MVS1 and MVS2 over the CTC link via Multi-Path Channel (MPC). (Transport Resource List [TRL] and LOCAL Major Node definitions are required in MVS1 and MVS2.)

This document uses these configurations:

Router Configuration
!
version 11.2
service udp-small-servers
service tcp-small-servers
!
interface TokenRing0/0
 ip address 172.26.7.16 255.255.255.0
 ring-speed 16
!
interface Channel1/0
 csna C010 70                      

!--- This is the Cisco Systems Network Architecture (SNA) connection to MVS1.

 csna C020 71                      

!--- This is the Cisco SNA connection to MVS2.

!
interface Channel1/2
 ip address 172.26.19.98 255.255.255.224
 no keepalive
 lan TokenRing 0
  adapter 1 4000.1241.1000         

!--- This is bound to the TN3270 server.

  adapter 30 4000.aaaa.0000        

!--- This is bound to the MVS1 Cisco SNA connection.

  adapter 31 4000.bbbb.0000        

!--- This is bound to the MVS2 Cisco SNA connection.

 tn3270-server
  dlur NETA.WALL NETA.MVS2         

!--- The DLUR: NETA.WALL and the DLUS: NETA.MVS2.

   lsap token-adapter 1 
    link CPAC  lsap C0   rmac 4000.aaaa.0000 rsap 04
    link MVS2  lsap C0   rmac 4000.bbbb.0000 rsap 04
   pu dlurpup eeeeffff 172.26.19.99
!
router eigrp 109
 network 172.26.0.0
!
line con 0
 exec-timeout 0 0
line aux 0
line vty 0 4
 password cisco
 login
!
end

XCA Major Node in MVS1: XCAMVS1
MVS1870 VBUILD TYPE=XCA
PR870   PORT   ADAPNO=30,CUADDR=870,SAPADDR=04,MEDIUM=RING,TIMER=60
*
GRP870  GROUP  ANSWER=ON,                                              X
               AUTOGEN=(5,U,P),                                        X
               CALL=INOUT,                                             X
               DIAL=YES,                                               X
               DYNPU=YES,                                              X
               DYNPUFX=CN,                                             X
               ISTATUS=ACTIVE

XCA Major Node in MVS2: XCAMVS2
MVS871  VBUILD TYPE=XCA
PR871   PORT   ADAPNO=31,CUADDR=871,SAPADDR=04,MEDIUM=RING,TIMER=60
*
GRP871  GROUP  ANSWER=ON,                                              X
               AUTOGEN=(5,U,P),                                        X
               CALL=INOUT,                                             X
               DIAL=YES,                                               X
               DYNPU=YES,                                              X
               DYNPUPFX=CN,                                            X
               ISTATUS=ACTIVE

LU Major Node in MVS2: LUCPCP
LUGRL    VBUILD TYPE=LUGROUP
DLUSYED  LUGROUP
327802   LU    DLOGMOD=D4C32782,LOGAPPL=NETTESTR,                      X
                MODETAB=ISTINCLM,USSTAB=USSL3270,SSCPFM=USS3270
327804E  LU    DLOGMOD=D4C32784,LOGAPPL=NETTESTR,                      X
               MODETAB=ISTINCLM,USSTAB=USSL3270,SSCPFM=USS3270
@        LU    DLOGMOD=D4C32782,LOGAPPL=NETTMVS2,                      X
               MODETAB=ISTINCLM,USSTAB=USSL3270,SSCPFM=USS3270

!--- The NETTESTR application is on MVS1. 
!--- This is specified with LOGAPPL=NETTESTR.

Switched Network (SWNET) Major Node in MVS2: SW1TSYSP
SW1TSYS  VBUILD TYPE=SWNET
*
*
TSYSPU   PU    ADDR=02,                                                X
               IDBLK=EEE,IDNUM=EFFFF,                                  X
               ISTATUS=ACTIVE,                                         X
               LUGROUP=DLUSYED,LUSEED=M3270L##,                        X
               PUTYPE=2,DLOGMOD=D4C32784,MODETAB=ISTINCLM,             X
               SSCPFM=USS3270,PACING=8,VPACING=8
M3270L01 LU    LOCADDR=01,LOGAPPL=TSOMVS1 

!--- PU TSYSPU is used for the Cisco TN3270 Server 
!--- session switching connection.

TRL Network Node in MVS1 for the CTC Connection: MPCM1ICN
************************************************************************
*  MVS1 READ  CUAS: A60,A70 CTC UNITAD 20,30                           *
*  MVS2 WRITE CUAS: B20,B30 CNC UNITAD 20,30                           *
*  MVS1 WRITE CUAS: B40,B50 CNC UNITAD 00,10                           *
*  MVS2 READ  CUAS: A00,A10 CTC UNITAD 00,10                           *
************************************************************************

MPCM1ICN VBUILD TYPE=TRL
MPCM1M2  TRLE  LNCTL=MPC,MAXBFRU=16,                                   X
               READ=(A60,A70),                                         X
               WRITE=(B40,B50)

LOCAL Major Node in MVS1 for the CTC Connection: TRLM1ICN
TRLM1ICN VBUILD TYPE=LOCAL
*       XID=YES,HPR=YES FOR NN ONLY
TRLM1PU1 PU    TRLE=MPCM1M2,                                           X
               ISTATUS=ACTIVE,VPACING=0, *XID=YES,HPR=YES              X
               SSCPFM=USSSCS,CONNTYPE=APPN,CPCP=YES

TRL Network Node in MVS2 for the CTC Connection: MPCM2NN
************************************************************************
*  MVS1 READ  CUAS: A60,A70 CTC UNITAD 20,30                           *
*  MVS2 WRITE CUAS: B20,B30 CNC UNITAD 20,30                           *
*  MVS1 WRITE CUAS: B40,B50 CNC UNITAD 00,10                           *
*  MVS2 READ  CUAS: A00,A10 CTC UNITAD 00,10                           *
************************************************************************

MPCM2NN  VBUILD TYPE=TRL
MPCM2M1  TRLE  LNCTL=MPC,MAXBFRU=16,
               READ=(A00,A10),
               WRITE=(B20,B30)

LOCAL Major Node in MVS2 for the CTC Connection: TRLM2NN
TRLM2NN  VBUILD TYPE=LOCAL
*******      USE XID=YES,HPR=YES  IF OTHER MVS IS NN
TRLM2PU1 PU    TRLE=MPCM2M1,                                           X
               ISTATUS=ACTIVE,VPACING=0,  *XID=YES,HPR=YES,            X
                SSCPFM=USSSCS,CONNTYPE=APPN,CPCP=YES

Verify

There is currently no verification procedure available for this configuration.

Troubleshoot

There is currently no specific troubleshooting information available for this configuration.

Related Information

Updated: Sep 09, 2005
Document ID: 12329