Document ID: 116739
Updated: Nov 15, 2013
Contributed by Carlos Lopez and Matthew Wronkowski, Cisco TAC Engineers.
Contents
Introduction
This document describes the best practices to use when you deploy port channels on the Cisco Nexus 1000V Series switch (N1KV). The N1KV requires port channels for port profiles that contain more than one interface per host.
Prerequisites
Requirements
Cisco recommends that you have knowledge of these topics:
- N1KV
- Cisco Unified Computing System (UCS)
- Cisco Nexus and Catalyst Series Switches
Components Used
The information in this document is based on these software and hardware versions:
- N1KV
- UCS
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
Configure
This section contains these configurations:
- N1KV on UCS B-Series Servers in End-Host Mode
- N1KV on UCS C-Series Servers or Rack Mount Servers Connected to Nexus 5000/7000 Switches with vPC
- N1KV on UCS C-Series Servers or Rack Mount Servers Connected to Switches without vPC
- N1KV on UCS C-Series Servers or Rack Mount Servers Connected to 6500 Virtual Switching System (VSS) or Stacking Switches
- N1KV on UCS C-Series Servers or Rack Mount Servers Connected to a Single Upstream Switch with a Static Port Channel
N1KV on UCS B-Series Servers in End-Host Mode
Cisco UCS uses two diverse paths between the blade and the upstream network. Currently, the Fabric Interconnects do not support Link Aggregation Control Protocol (LACP)/Virtual Port Channel (vPC) southbound toward the blades. This means that a static port channel from the N1KV perspective must be used. MAC Pinning is required, since the upstream switches do not support multichassis EtherChannel.
# VSM configuration
port-profile type ethernet system-uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 100, 101, 102, 103, 200 - 300
channel-group auto mode on mac-pinning
no shutdown
system vlan 100,101,102,103 state enabled
# Upstream switch configuration
-None required
N1KV on UCS C-Series Servers or Rack Mount Servers Connected to Nexus 5000/7000 Switches with vPC
In this topology, each rack server is physically connected to two different Nexus switches - one cable to each switch. LACP is the preferred mode, because it allows the best traffic distribution and non-disruptive addition/subtraction of links. It is assumed that the upstream Nexus switches already have a vPC peer link configured.
# VSM configuration
feature lacp
lacp offload
port-channel load-balance ethernet source-mac
port-profile type ethernet system-uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 100, 101, 102, 103, 200 - 300
channel-group auto mode active
no shutdown
system vlan 100,101,102,103
state enabled
# Nexus 5k/7k switches #1 & #2 configuration
interface port-channel1000
switchport mode trunk
vpc 1000
switchport trunk allowed vlan 100-103,200-300
spanning-tree port type edge trunk
spanning-tree bpduguard enable
spanning-tree bpdufilter enable
no lacp suspend-individual <- Nexus 7k only!!!
!
interface Ethernet1/11
description ESX-Host1
switchport mode trunk
switchport trunk allowed vlan 100-103,200-300
spanning-tree port type edge trunk
spanning-tree bpduguard enable
spanning-tree bpdufilter enable
channel-group 1000 mode active
N1KV on UCS C-Series Servers or Rack Mount Servers Connected to Switches without vPC
In this topology, each rack server is physically connected to two different switches, but vPC is not available. The only supported configuration is MAC Pinning. This configuration is identical to that used on UCS B-Series servers. A static port channel (mode on) is not supported, since the upstream switches do not support a multichassis EtherChannel technology.
# VSM configuration
port-profile type ethernet system-uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 100, 101, 102, 103, 200 - 300
channel-group auto mode on mac-pinning
no shutdown
system vlan 100,101,102,103
state enabled
# Upstream switch configuration
-None required
N1KV on UCS C-Series Servers or Rack Mount Servers Connected to 6500 VSS or Stacking Switches
In this topology, the upstream switches act as a single chassis. This allows the N1KV to connect with LACP.
# VSM configuration
feature lacp
lacp offload
port-profile type ethernet system-uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 100, 101, 102, 103, 200 - 300
channel-group auto mode active
no shutdown
system vlan 100,101,102,103
state enabled
# 6500 VSS configuration
interface Port-channel1000
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 100-103,200-300
switchport mode trunk
spanning-tree portfast edge trunk
spanning-tree bpduguard enable
spanning-tree bpdufilter enable
!
interface GigabitEthernet1/1/1
description ESX-Host1 adapter 1
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 100-103,200-300
switchport mode trunk
spanning-tree portfast edge trunk
spanning-tree bpduguard enable
spanning-tree bpdufilter enable
channel-group 1000 mode active
!
interface GigabitEthernet2/1/1
description ESX-Host1 adapter 2
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 100-103,200-300
switchport mode trunk
spanning-tree portfast edge trunk
spanning-tree bpduguard enable
spanning-tree bpdufilter enable
channel-group 1000 mode active
N1KV on UCS C-Series Servers or Rack Mount Servers Connected to a Single Upstream Switch with a Static Port Channel
In this topology, the servers are single-homed to an upstream switch. This topology provides no switch redundancy and is not a best practice.
# VSM configuration
port-profile type ethernet system-uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 100, 101, 102, 103, 200 - 300
channel-group auto mode on
no shutdown
system vlan 100,101,102,103
state enabled
# Upstream Nexus switch
interface port-channel 1000
switchport mode trunk
switchport trunk allowed vlan 100-103,200-300
spanning-tree port type edge trunk
spanning-tree bpduguard enable
spanning-tree bpdufilter enable
!
interface Ethernet1/11
description ESX-Host1
switchport mode trunk
switchport trunk allowed vlan 100-103,200-300
spanning-tree port type edge trunk
spanning-tree bpduguard enable
spanning-tree bpdufilter enable
channel-group 1000 mode on
Verify
Use this section in order to confirm that your configuration works properly.
show run interface po{X} membership
show port-channel summary
Troubleshoot
This section provides information you can use in order to troubleshoot your configuration.
show port-channel summary
show port-channel internal event-history [all|errors]debug lacp all
Open a Support Case (Requires a Cisco Service Contract.)
Related Cisco Support Community Discussions
The Cisco Support Community is a forum for you to ask and answer questions, share suggestions, and collaborate with your peers.
Refer to Cisco Technical Tips Conventions for information on conventions used in this document.