Document ID: 116122
Updated: May 03, 2013
Contributed by Dixon Ho and Vishal Mehta, Cisco TAC Engineers.
Contents
Introduction
This document describes failure messages and general troubleshooting procedures for the Cisco Fabric Extender (FEX) power supply.
Continuous Messages for GPIO Access Failure
In this example, the logs reveal continuous messages for general purpose input/output (GPIO) access failure:
%SATCTRL-FEX133-2-SOHMS_DIAG_ERROR: FEX-133 Module 1: Runtime diag detected major event: GPIO access failure
%SATCTRL-FEX133-4-SOHMS_PS_GPIO: FEX-133 System PS access failure
on Power supply: 1
%SATCTRL-FEX133-4-SOHMS_PS_GPIO: FEX-133 System PS access failure
on Power supply: 2
The appropriate solution depends upon the software version on the Nexus 5000 or Nexus 7000.
Nexus 5000 and NX-OS Version Earlier than 5.0(3)N2(1)
This is a known cosmetic issue; see Cisco bug ID CSCtl77867 (FEX PS runtime diag detected major event: GPIO access failure). The solution is to reload the FEX or upgrade to version 5.0(3)N2(1) or later.
Nexus 5000 and NX-OS Version 5.0(3)N2(1) or Later
See Cisco bug ID CSCtz84683 (continuous GPIO access failure message seen on FEX).
Nexus 7000
See Cisco bug ID CSCtr77620 (FEX: System minor alarm on power supply 1 & Recovered).
Other Failure Messages for FEX Power Supply
This example shows other failure messages for the FEX power supply:
%SATCTRL-FEX104-2-SOHMS_DIAG_ERROR: FEX-104 Module 1: Runtime diag detected major event:
Voltage failure on power supply: 1
%SATCTRL-FEX104-2-SOHMS_DIAG_ERROR: FEX-104 System minor alarm on power supply 1: failed
%SATCTRL-FEX104-2-SOHMS_DIAG_ERROR: FEX-104 Recovered: System minor alarm on power
supply 1: failed
Methods to resolve these issues include:
- Reseat the FEX power supply; use the redundant power supply to ensure the power does not go offline.
- Submit a Return Material Authorization (RMA) for the FEX power supply; use the redundant power supply to ensure the power does not go offline.
- Repeat these steps for the second power supply.
Troubleshooting
The first step in troubleshooting is to check for hardware and power issues. If you have a software issue, error messages continue even after you swap hardware.
Review and answer these questions in order to help define the circumstances of the failure:
- How many FEX power supplies are affected ?
- For a minor alarm, did you swap the input source, and did that make any difference?
- Do you have other FEX power supplies that are having issues?
- Do you have any other boxes of the same power source?
- Did you replace the power cord?
- Was there a power surge or glitch in the environment?
Gather output from these commands in order to investigate the failures:
- show sprom fex 100 all
- show logging log | no-more
- show tech fex 100 | no-more
- attach fex 100
- show platform software satctrl trace
Related Information
Open a Support Case (Requires a Cisco Service Contract.)
Related Cisco Support Community Discussions
The Cisco Support Community is a forum for you to ask and answer questions, share suggestions, and collaborate with your peers.
Refer to Cisco Technical Tips Conventions for information on conventions used in this document.