Guest

Cisco Lightstream ATM Switches

LightStream 1010 New Processor Introduction

Product Bulletin No. 802


LightStream 1010 New Processor Introduction


Cisco Systems, Inc., is announcing the introduction of a new processor for the LightStream® 1010 multiservice ATM switch. This product bulletin explains the features and benefits of the new processor and compares it with the existing processor.

Orderability for the L1010-ASP-C-FC1 and L1010-ASP-C-FCPFQ will be turned on Calendar Q4, `98. Two part numbers will be available that are consistent with the current shipping CPU platforms.

Table 1   LS1010 Product Description and Software Release

New CPU Description Minimum Software Release

L1010-ASP-C-FC1

ATM switch processor with FC-per-class queuing

WAS3-6 or WAS4-6

L1010-ASP-C-FCPFQ

Multiservice ATM switch route processor existing CPU

WAS4-6

L1010-ASP-B-FC1

ATM switch processor with FC-per-class queuing

WAS1-3

L1010-ASP-B-FCPFQ

ATM switch processor with FC-per-flow queuing

WAS4-2

Comparison of the L1010-ASP-B-FC1 and the L1010-ASP-C-FC1

The two versions of the ATM switch processor (ASP) with FC-1 are functionally equivalent. The modules have no differences in feature, functionality, or performance.

The ASP with FC-1 is ideally suited for campus backbone networks and workgroups where the need for enhanced traffic management is minimal.

Comparison of the L1010-ASP-B-FCPFQ and the L1010-ASP-C-FCPFQ

For ATM-only applications, the L1010-ASP-B-FCPFQ and L1010-ASP-C-FCPFQ are functionally equivalent. The modules have no differences in feature, functionality, or performance.

The ASP with FC-PFQ is ideally suited to the enterprise edge and alternative service provider backbones. Below is a table of the features and benefits associated with the FC-PFQ feature card. FC-PFQ is recommended for all low-speed interfaces such as T3, E3, and below and for any unit that interfaces to a WAN or service provider.

Table 2   NEED CAPTION

Feature Benefit

TAG Switching (MPLS)

IP and ATM integration

VC Merge

Resource sharing, AAL5 Frame sequencing

Per-VC and-VP Queuing

Rate limiting to slow-speed destinations or to meet contract

Shaped VP Tunnels

Single service category over ATM WANs

Hierarchical-Shaped VP Tunnels

Multiservice applications over ATM WANs

Per-VC Snooping

Nondisruptive monitoring and troubleshooting

ABR Support (EFCI and RR)

Standards-based ABR support

Weighted Early Packet Discard

Differentiated service (up to 16)

Enhanced Clock Capabilities

Smooth switchover of clock source

Table 3   Future Hardware for which FC-PFQ is Required

Part Number Description

C85MS-8E1-IMA-120

8-port E1 120-ohm IMA port adapter module

C85MS-8E1-IMA-75

8-port E1 75-ohm IMA port adapter module

C85MS-8T1-IMA

8-port TI IMA port adapter module

The unique value that the L1010-ASP-C-FCPFQ brings is its ability with future platform enhancements to support both Layer 3 and ATM switching within a single platform. The ASP-B will not support Layer 3 interfaces.

The L1010-ASP-C-FCPFQ is identical to the C8515-MSRP, which will be the processor used in the Catalyst 8510 multiservice switch router (MSR). This Layer 3 and ATM integration will require an additional future hardware component that will utilize one entire slot in the LightStream 1010 or Catalyst® 8510 MSR.

Table 4   Layer 3 Capabilities

Processor Platform Layer 3 (Ethernet) and ATM Switching

L1010-ASP-B-FCPFQ

LightStream 1010, Catalyst 5500

No

L1010-ASP-C-FCPFQ

LightStream 1010, Catalyst 5500

Yes

C8515-MSRP

LightStream 1010, Catalyst 5500, Catalyst 8500

Yes

Most anticipated questions and answers follow:

Q. When will the hardware ship that enables the Layer 3 and ATM switching integration?

A. See the Catalyst 8500 series FAQ.

Q. Which Catalyst 85xx campus switch router (CSR) interfaces can be deployed in the MSR?

A. With future software and one-slot card, Catalyst 8510 CSR interfaces will be deployable in the Catalyst 8510 MSR. With future software and one-slot card, Catalyst 8540 CSR interfaces will be deployable in the Catalyst 8540 MSR.

Q. Can Catalyst 85xx CSR modules be deployed in the MSR prior to this hardware integration?

A. No.

Q. Will there be an upgrade path to the MSR technology from FC-1-based cards or from an L1010-ASP-B-FCPFQ?

A. Absolutely. Use the technology migration plan.

Q. Why is the silkscreen on the L1010-ASP-C-FCPFQ not consistent with previous ASP modules?

A. A LightStream 1010 with L1010-ASP-C-FCPFQ is functionally equivalent to a C8515-MSRP. Hence for ease of identification they have the same silkscreen. This setup enables Layer 3 and ATM-capable units to be easily identified in the field.

Q. Can a C8515-MSRP work in a LightStream 1010 or Catalyst 5500?

A. Yes, it is the same as an L1010-ASP-C-FCPFQ.

Q. Can an L1010-ASP-C-FCPFQ work in a Catalyst 8510 MSR?

A. Yes, it is the same as a C8515-MSRP.