Data Sheet
Cisco ONS 15540 ESPx
Extended Services Platform
The Cisco® ONS 15540 ESPx Extended Services Platform is a highly modular, flexible, and scalable 32-channel, next-generation dense wavelength-division multiplexing (DWDM) platform that integrates storage area networking (SAN), data networking, SONET, and SDH technologies over an ultra-high bandwidth, intelligent optical infrastructure that can support any packet, over any wavelength, on any platform.
ONS 15540ESPx

Key Product Benefits
- Scalable, flexible, modular architecture in a high-density compact footprint—Provides excellent operational support and scalable network expansion through its hot-swappable, modular lines cards, transponders, and optical multiplexers
- Simple network consolidation and comprehensive Multiservice support—Cisco ONS 15540 2.5-Gb transparent transponders with Small Form-Factor Pluggable (SFP) transceivers and the 10 GBase-LR Ethernet transponders support a comprehensive range of SAN, data, and SONET/SDH applications
- Multiservice integration—Transports Enterprise System Connection (ESCON); 1-Gb/2-Gb IBM Fiber Connection (FICON); 1-Gb/2-Gb Fibre Channel SAN protocols; Fast Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet for data networking; and SONET/SDH at OC-3/STM1, OC-12/STM4, and OC-48/STM12 data rates
- Cisco IOS® Software —Robust and reliable operating system with well-known command-line interface (CLI) for smooth integration into existing Cisco IOS network infrastructures
- High availability for mission-critical networks—Provides 99.999 percent availability for demanding managed-network service providers and enterprise business-continuance applications, with hardware redundancy and automatic protection switching
- Scaleable optical multiplexers—4-/8-channel optical add/drop multiplexers (OADMs), along with the 32-channel Array Wave Guide (AWG) optical multiplexer module, provides optical multiplexing optimized for low channel count and effective wavelength use, or high-density applications and improved cost per lambda
- Flexible cable management system—Provides efficient control of all client and system optical cables through cable storage and cross-connect drawers
- Front panel access to transponder International Telecommunication Union (ITU) wavelengths—Provides flexible input/output (I/O) connectivity options and improved installation and maintenance
- Direct I/O access to multiplexer/demultiplexer (mux/demux)—Supports direct DWDM wavelength insertion of subtending platforms into the Cisco ONS 15540 ESPx filters
- Variable-rate SFPs—SFP transceivers for Type 2 transponders support any transmission speed between 16-Mbps and 2.5-Gbps
- Cisco Systems® service and support—Cisco SMARTnet® service and support for the Cisco ONS Family of optical products easily integrates into existing Cisco SMARTnet service programs
Platform Features
- Support for 32 protected or 64 unprotected 2.5-Gb wavelengths
- Support for 16 protected or 32 unprotected 10-Gb Ethernet wavelengths
- Multiplexer motherboards (MMMB) with or without integrated optical supervisory channel (OSC)
- Flexible 4- and 8-channel OADM with or without OSC support
- High Density 32-channel AWG terminal multiplexer/demultiplexer with OSC
- Dual CPU modules using Cisco IOS Software
- -48VDC power inputs or optional 100-240VAC redundant rectifiers
- 2.5-Gb line card motherboards (LCMBs) providing splitter or nonsplitter support for up to 4 x 2.5-Gb transponders (8 LCMBs per chassis for 32-channel support)
- 10-Gb LCMBs providing splitter or nonsplitter support for up to 2 x 10 Gigabit Ethernet transponders (8 LCMBs per chassis for 16-ch support)
- Transponders types
-
- Type 1—Tunable ITU Wavelength—Variable Client rate 16-622 Mbps 1310 nm multimode transponder
- Type 1—Tunable ITU Wavelength—Variable client rate 16-Mbps/2.5-Gbps 1310 nm single-mode transponder
- Type 2—Tunable ITU Wavelength extended-range transponder with SFP client support for 850 nm multimode and 1310 nm multimode/single-mode interfaces
- 10 GBase-LR 1310 nm single-mode 10 GbE transponder with comprehensive performance monitoring
- Multiprotocol support includes:
-
- IBM ESCON and Geographically Dispersed Parallel Sysplex (GDPS)
- 1-Gb/2-Gb FICON (ISC1 and ISC3),
- 1-Gb/2-Gb Fibre Channel
- Token ring
- Fiber Distributed Data Interface (FDDI)
- Fast Ethernet
- Gigabit Ethernet
- 10 Gigabit Ethernet (10GBase-LR)
- ATM/SONET/SDH at OC-3/STM1, OC-12/STM4, and OC-48/STM12
- D1 video
- Fault-tolerant hot-swappable modules
- Modular optical interconnect system with external connectorization
-
- "Direct-connect" cross-connect system with multipath push-on (MPO) cables between LCMB and MMMB
- "Cross-connect" fiber management system with cross-connect drawer(s) for access to individual ITU wavelengths between LCMB and MMMB
Node Topologies
- Point to point
- Hubbed ring
- Mesh ring
Protection
- Optical—Unidirectional path switched ring (O-UPSR)
- Automatic protection switching (APS), uni- or bi-directional
- Client side: 1+1 and Y cable
- Trunk side: 1+1 and splitter
- Fiber route diversity: 1:1 path protection with switchover time < 50ms
Optical Management
- Per-fiber OSC at 2.5-Gb
- Per wavelength OSC with 10-Gbps transponders
Network Management Support
- Cisco IOS Software—Robust, reliable operating system and CLI
- CiscoView—Resource, configuration, and security management,
- Cisco Transport Manager—Comprehensive network and element management
- Simple Network Management Protocol (SNMP)—Open Systems MIB support
CPU Module Specifications
- Two redundant CPU modules per chassis
- RJ-45 RS-232 console port and auxiliary port
- Fast Ethernet port (network management)
- One PCMCIA slot
- Status and alarm LEDs
- Cisco IOS Software, Web-based GUI, and SNMP management
Tables 1-5 list the specifications for the Cisco ONS 15540 ESPx transponder, SFP (multirate), SFP (variable rate), OADM, and 32-channel terminal multiplexer/demultiplexer, respectively.
Regulatory Standards Compliance
Products bear CE marking indicating compliance with the 89/366/EEC and 73/23/EEC directives, which include the following safety and EMC standards:
Safety
- UL 60950
- CAN/CSA-C22.2 No. 60950-00
- EN 60950
- IEC 60950
- TS 001
- AS/NZS 3260
- IEC 60825-1, -2
- EN 60825-1, -2
- 21CFR 1040
EMC
- FCC Part 15 (CFR 47) Class A
- ICES-003 Class A
- EN 55022 Class A
- CISPR22 Class A
- AS/NZS 3548 Class A
- VCCI Class A
- EN 55024
- ETS 300 386
- EN 50082-1
- EN 61000-3-2
- EN 61000-3-3
Industry EMC, Safety and Environmental Standards
- GR-63-Core NEBS Level 3 Requirements
- GR-1089-Core NEBS Level 3 Requirements
- ETSI 300-019
Table 1 Cisco ONS 15540 ESPx Transponder Specifications
|
ONS 15540 ESPx Transparent Transponder Type 1/Multimode |
ONS 15540 ESPx Transparent Transponder Type 1/Single mode |
ONS 15540 ESPx Extended Range Type 2 |
|
Client |
Trunk |
Client |
Trunk |
Client |
Trunk |
Tx Power |
-5 dBm
|
4 to 8 dBm
|
-5 dBm
|
4 to 8 dBm
|
SFP specific
|
5 to 10 dBm
|
Rx Sensitivity |
-25 dBm
|
-28 dBm
|
-19 dBm
|
-28 dBm
|
SFP specific
|
-28 dBm
|
Dispersion |
1800 ps/nm
|
1800 ps/nm
|
3200 ps/nm
|
Supported Protocols |
- Fast Ethernet
- Multimode ESCON
- Sysplex Timer external throughput rate (ETR)
- Control Link Oscillator (CLO)
- FDDI
- D1 video
- ONET/SDH OC-3/STM-1, OC-12/STM-4
- Packet over SONET (POS) for OC-3 and OC-12
|
- Fast Ethernet
- Single Mode ESCON
- Sysplex Timer (ETR)
- CLO
- FDDI
- D1 video
- SONET/SDH OC-3/STM-1, OC-12/STM-4,OC-48/STM-16
- POS
- Gigabit Ethernet
- 1-Gb/2-Gb FICON/ISC1/ISC3
- 1-Gb/2-Gb Fibre Channel
|
- Fast Ethernet
- MM/SM ESCON
- Sysplex Timer (ETR)
- CLO
- FDDI
- D1 video
- SONET/SDH OC-3/STM-1, OC-12/STM-4, OC-48/STM-16
- POS
- Gigabit Ethernet
- 1-Gb/2-Gb FICON/ISC1/ISC3
- 1-Gb/2-Gb Fibre Channel
|
Bit Rate Range |
16-Mb to 622-Mb
|
16-Mb to 2.5-Gb
|
16-Mb to 2.5-Gb
|
Client Interface |
MM ((62.5/125mm)—1310nm
BER—10-12 (10-15 ESCON)
Connector type-SC
|
SM (ITU-T G.652)—1310/1550nm
BER—10-12 (10-15 ESCON)
Connector type-SC
|
MM—850/1310 (62.5/125mm)
SM—1310/1550 (ITU-T G.652)
BER—10-12 (10-15 ESCON)
Connector type-SFP dependent
|
Trunk Interface |
Tunable ITU laser
Fiber—SM (ITU-T G.652)
Connector-MU
|
Tunable ITU laser
Fiber—SM (ITU-T G.652)
Connector-MU
|
Tunable ITU laser
Fiber—SM (ITU-T G.652)
Connector-MU
|
|
Note: All Cisco ONS 15500 transponders have 3R (regeneration, retiming, reshaping) capabilities, digital monitoring, and are hot-swappable.
Table 2 SFP Specifications (Multi-Rate)
SFP Model Number |
15500-XVRA-01A2 |
15500-XVRA-02C1 |
15500-XVRA-02C2 |
15500-XVRA-03B1 |
15500-XVRA-03B2 |
15500-XVRA-06B1 |
15500-XVRA-07B1 |
Fiber/Data Rates Supported |
1310nm MM OC3/STM1, ESCON |
850 nm MM GE, FC1 |
850 nm MM FC1/ FC2* |
1310 nm SM GE, FC1 |
1310 nm SM GE, FC1 FC2 |
1310 nm SM OC12/STM-4 |
1310 nm SM OC48/STM-16 |
Connector type
|
MTRJ
|
LC
|
LC
|
LC
|
LC
|
LC
|
LC
|
Receiver Specifications |
Receive sensitivity (min)
|
-31 dBm
|
-18 dBm
|
-15 dBm*
|
-20.5 dBm
|
-20.5 dBm*
|
-28 dBm
|
-18 dBm
|
Receive sensitivity (typical)
|
|
-21 dBm
|
-20.5 dBm*
|
-25 dBm
|
-22 dBm*
|
-31 dBm
|
-22 dBm
|
Receive overload
|
-14 dBm
|
0 dBm
|
0dBm
|
-3 dBm
|
-3 dBm
|
-7 dBm
|
-3 dBm
|
Input wavelength
|
1280-1380 nm
|
770-860 nm
|
770-860 nm
|
1270-1600 nm
|
1270-1600 nm
|
1100-1600 nm
|
1270-1600 nm
|
Optical reflectance
|
|
12 dB Ret. Loss
|
12 dB Ret. Loss
|
12 dB Ret. Loss
|
12 dB Ret. Loss
|
|
12 dB Ret. Loss
|
BER
|
10-15
|
10-12
|
10-12
|
10-12
|
10-12
|
10-10
|
|
Fiber type/micron
|
MM 50/62.5
|
MM 50/62.5
|
MM 50/62.5
|
SMF-9
|
SMF-9
|
SMF-9
|
SMF-9
|
Transmitter Specification |
Transmitter power (max)
|
-15 dBm
|
-4 dBm
|
-4 dBm
|
-3 dBm
|
-3 dBm
|
-8 dBm
|
-3 dBm
|
Transmitter power (min)
|
-19.5 dBm
|
-9.5 dBm
|
-9 dBm
|
-9.5 dBm
|
-9.5 dBm
|
-15 dBm
|
-9.5 dBm
|
Output wavelength
|
1280-1380 nm
|
830-860 nm
|
830-860 nm
|
1275-1350 nm
|
1275-1350 nm
|
1261-1360 nm
|
1285-1340 nm
|
Fiber type/micron
|
MM 50/62.5
|
MM 50/62.5
|
MM 50/62.5
|
SMF-9
|
SMF-9
|
SMF- 9
|
SMF-9
|
Typical distance
|
2km Max on MM F
|
500m/50 micron MMF
|
300m/50 micron MMF
|
Up to 10km on SMF
|
Up to 10km on SMF
|
2km on SMF-9
|
2km on SMF-9
|
|
|
300m/62.5 micron MMF
|
150m/62.5 micron MMF
|
|
|
|
|
|
Table 3 Variable Rate SFP Specifications
SFP Model Number |
15500-XVRA-10A1 |
15500-XVRA-10B1 |
15500-XVRA- 11A1 |
15500-XVRA- 11B1 |
15500- XVRA-12B1 |
Fiber/Data Rates Supported |
Low-Band MM 8-200 Mbps |
Low-Band SM 8-200 Mbps |
Mid-Band MM 200-622 Mbps |
Mid-Band SM 200 Mbps -1.25 Gbps |
High-Band SM 1.062-2.488 Gbps |
Wavelength
|
1310 nm
|
1310 nm
|
1310 nm
|
1310 nm
|
1310 nm
|
Connector type
|
LC
|
LC
|
LC
|
LC
|
LC
|
Fiber type/micron
|
MM 62.5/125
|
SM 9/125
|
MM 62.5/125
|
SM 9/125
|
SM 9/125
|
Receiver Specifications |
Receive sensitivity @ 10-10 BER
|
|
|
-26 dBm
|
|
-18 dBm
|
Receive sensitivity @10-12 BER
|
-32 dBm
|
-32 dBm
|
-25 dBm
|
-20 dBm
|
|
Receive sensitivity @ 10-15 BER
|
-29 dBm
|
|
|
|
|
Receive overload @ 10-10 BER
|
|
|
|
-3 dBm
|
-3 dBm
|
Receive overload @10-12 BER
|
-14 dBm
|
- 3 dBm
|
-14 dBm
|
|
|
Input wavelength
|
1000-1600 nm
|
1000-1600 nm
|
1000-1600 nm
|
1000-1600 nm
|
1000-1600 nm
|
Transmitter Specifications |
Transmitter power (max)
|
-14 dBm
|
-4 dBm
|
-14 dBm
|
-3 dBm
|
-3 dBm
|
Transmitter power (min)
|
-19 dBm
|
-8 dBm
|
-20 dBm
|
-9 dBm
|
-10 dBm
|
Output wavelength
|
1280-1380 nm
|
1260-1360 nm
|
1270-1380 nm
|
1285-1345 nm
|
1266-1360 nm
|
Typical distance
|
2km
|
2km
|
500m
|
10km
|
2km
|
|
Multiplexer Options
The Cisco ONS 15540 ESPx DWDM platform supports five different optical multiplexer options:
- 4-channel OADM with OSC—Bands A-H
- 4-channel OADM without OSC—Bands A-H
- 8-channel OADM with OSC—Bands AB/CD/EF/GH
- 8-channel OADM without OSC—Bands AB/CD/EF/GH
- 32-channel AWG with OSC
Table 4 OADM Specifications
Description |
Specification |
Mux/demux motherboard (MMMB) |
With and without optical splitter
|
Dimensions
|
18 x 9 in (47.5 x 22.9 cm)
|
Weight
|
3.5 lbs (1.59 kg)
|
4- and 8-channel OADM modules |
|
Dimensions
|
1.0 x 3.3 x 7.7 in (2.5 x 8.4 x 19.6 cm)
|
Weight
|
1.0 lbs (0.45 kg)
|
Transport-side mux/demux |
|
OSC
|
1562.23 nm
|
Wavelengths
|
32 ITU G.692
|
Connector Type
|
MU
|
BER |
10E-15 for ESCON, 10E-12 for all other applications
|
Receiver sensitivity |
-32 dBm typical, -28 dBm max
|
OSNR |
To guarantee 10E-12 BER on laser receiver, OSNR should be 19 dB for -28 dBm sensitivity and 23 dB for 32 dBm sensitivity.
|
Receive overload |
-8 dBm max
|
Input wavelength |
1430-1580nm
|
Optical reflectance |
-27 dB
|
Transmitter power |
4 dBm min, 6 dBm typical, 8 dBm max
|
Wavelength accuracy (room temperature) |
±0.015 nm
|
Output wavelength |
1530.33-1560.61 nm
|
Side mode suppression |
30 dB
|
Dispersion tolerance |
1800 ps/nm 2 dB penalty
|
Chirp |
0.35-0.40 amperes (measured)
|
Operating temperature |
0-40° Celsius [ADD F]
|
Relative humidity, maximum |
0-90 to 95% noncondensing
|
|
Table 5 32-Channel Terminal Multiplexer/Demultiplexer Specifications
Description |
Specification |
Mux/demux motherboard (MMMB) |
With and without optical splitter
|
Dimensions
|
18 x 9 in (47.5 x 22.9 cm)
|
Weight
|
3.5 lbs (1.59 kg)
|
32-channel AWG terminal mux/demux |
|
Dimensions
|
13.8 x 8.6 in (33cm x 22 cm)
|
Weight
|
3.5 lbs (1.59 kg)
|
Operating temperature
|
0 ~ 65ºC
|
Storage temperature
|
-40 to +85ºC
|
Requirement |
Pass band
|
±12.5GHz
|
Pass band shape
|
Gaussian
Flattop acceptable
|
Insertion loss
|
< 5.4dB (with connectors)
|
Insertion loss uniformity among 33 channels
|
< 1.35dB (with connectors)
|
Insertion loss uniformity within a band
|
< 0.75dB (with connectors)
|
Total crosstalk
|
< 25dB (DEMUX)
< 15dB (MUX)
|
Tap ratio
|
-20±1dB (with connectors)
|
PDL
|
< 0.5dB
|
Chromatic dispersion
|
< ±15ps/nm
|
PMD
|
< 0.5ps
|
Return loss
|
> 40dB
|
Directivity
|
> 45dB
|
Total taximum optical power
|
> 250mW
|
Fiber type
|
SMF-28 or equivalent
|
Connector for common and OSC, monitor
|
Low loss tuned MU/UPC
|
Connector for add and drop channels
|
Low loss MTP female/APC
|
Insertion loss of MU connector
|
< 0.15 dB
|
Insertion loss of MTP connector
|
< 0.35 dB
|
Bending radius
|