Table Of Contents
Fibre Channel Commands
cfs distribute
cfs ipv4 distribute
cfs ipv4 mcast-address
cfs ipv6 distribute
cfs ipv6 mcast-address
cfs region
cfs staggered-merge
clear device-alias
clear fcdomain
clear fcflow stats
clear fcns statistics
clear fcsm log
clear fcs statistics
clear fctimer session
clear fspf counters
clear port-security
clear rlir
clear rscn session
clear rscn statistics
clear zone
device-alias abort
device-alias commit
device-alias database
device-alias distribute
device-alias import fcalias
device-alias mode
device-alias name
device-alias rename
discover custom-list
discover scsi-target
fabric profile
fabric-binding activate
fabric-binding database copy
fabric-binding database diff
fabric-binding database vsan
fabric-binding enable
fcalias clone
fcalias name
fcalias rename
fcdomain
fcdomain abort vsan
fcdomain commit vsan
fcdomain distribute
fcdomain rcf-reject
fcdroplatency
fcflow stats
fcid-allocation
fcinterop fcid-allocation
fcns no-auto-poll
fcns proxy-port
fcns reject-duplicate-pwwn vsan
fcping
fcroute
fcs plat-check-global
fcs register
fcs virtual-device-add
fcsp
fcsp dhchap
fcsp enable
fcsp reauthenticate
fcsp timeout
fctimer
fctimer abort
fctimer commit
fctimer distribute
fctrace
fdmi suppress-updates
feature npiv
fspf config
fspf cost
fspf dead-interval
fspf enable
fspf hello-interval
fspf passive
fspf retransmit-interval
in-order-guarantee
interface fc
interface san-port-channel
interface vfc
lldp
lldp (interface)
logging abort
logging commit
logging distribute
member (fcalias configuration mode)
member (zone configuration mode)
member (zoneset configuration mode)
npiv enable
npv auto-load-balance disruptive
npv enable
npv traffic-map
port-security
port-security abort
port-security commit
port-security database
port-security distribute
port-security enable
port-track enable
port-track force-shut
port-track interface
purge fcdomain fcid
rlir preferred-cond fcid
rscn
rscn abort
rscn commit
rscn distribute
rscn event-tov
san-port-channel persistent
scsi-target
switchport
switchport ignore bit-errors
system default switchport
system default zone default-zone permit
system default zone distribute full
trunk protocol enable
vsan database
wwn secondary-mac
wwn vsan
zone clone
zone commit
zone compact
zone copy
zone default-zone
zone merge-control restrict vsan
zone mode enhanced
zone name (configuration mode)
zone name (zone set configuration mode)
zone rename
zoneset (configuration mode)
zoneset (EXEC mode)
Fibre Channel Commands
This chapter describes the Cisco NX-OS Fibre Channel and virtual Fibre Channel commands available on Cisco Nexus 5000 Series switches.
cfs distribute
To enable or disable Cisco Fabric Services (CFS) distribution on the switch, use the cfs distribute command. To disable this feature, use the no form of the command.
cfs distribute
no cfs distribute
Syntax Description
This command has no other arguments or keywords.
Command Default
CFS distribution is enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
By default CFS is in the distribute mode. In the distribute mode, fabric-wide distribution is enabled. Applications can distribute configuration data to all CFS-capable switches in the fabric where the application exists. This is the normal mode of operation.
If you disable CFS distribution by entering the no cfs distribute command, the following events occur:
•
The CFS commands continue to operate. However, CFS and the applications using CFS on the switch are isolated from the rest of the fabric even though there is physical connectivity.
•
All CFS operations are restricted to the isolated switch.
•
CFS operations (for example, lock, commit, and abort) initiated at other switches do not have any effect at the isolated switch.
•
CFS distribution is disabled over both Fibre Channel and IP.
Examples
The following example shows how to disable CFS distribution:
switch(config)# no cfs distribute
The following example shows how to reenable CFS distribution:
switch(config)# cfs distribute
Related Commands
Command
|
Description
|
show cfs status
|
Displays whether CFS distribution is enabled or disabled.
|
cfs ipv4 distribute
To enable Cisco Fabric Services (CFS) distribution over IPv4 for applications that want to use this feature, use the cfs ipv4 command. To disable this feature, use the no form of the command.
cfs ipv4 distribute
no cfs ipv4 distribute
Syntax Description
This command has no arguments or keywords.
Command Default
CFS distribution is enabled. CFS over IP is disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
All CFS over IP enabled switches with similar multicast addresses form one CFS over IP fabric. CFS protocol-specific distributions, such as the keepalive mechanism for detecting network topology changes, use the IP multicast address to send and receive information.
Observe the following guidelines when using this command:
•
If a switch is reachable over both IP and Fibre Channel, application data will be distributed over Fibre Channel.
•
You can select either an IPv4 or IPv6 distribution when CFS is enabled over IP.
•
Both IPv4 and IPv6 distribution cannot be enabled on the same switch.
•
A switch that has IPv4 distribution enabled cannot detect a switch that IPv6 distribution enabled. The switches operate as if they are in two different fabrics even though they are connected to each other.
Examples
The following example shows how to disable CFS IPv4 distribution:
switch(config)# no cfs ipv4 distribute
This will prevent CFS from distributing over IPv4 network.
Are you sure? (y/n) [n]
The following example shows how to reenable CFS IPv4 distribution:
switch(config)# cfs ipv4 distribute
Related Commands
Command
|
Description
|
cfs ipv4 mcast-address
|
Configures an IPv4 multicast address for Cisco Fabric Services (CFS) distribution over IPv4.
|
show cfs status
|
Displays whether CFS distribution is enabled or disabled.
|
cfs ipv4 mcast-address
To configure an IPv4 multicast address for Cisco Fabric Services (CFS) distribution over IPv4, use the cfs ipv4 mcast-address command. To disable this feature, use the no form of the command.
cfs ipv4 mcast-address ipv4-address
no cfs ipv4 mcast-address ipv4-address
Syntax Description
ipv4-address
|
Specifies an IPv4 multicast address for CFS distribution over IPv4. The range of valid IPv4 addresses is 239.255.0.0 through 239.255.255.255, and 239.192.0.0 through 239.251.251.251.
|
Command Default
Multicast address: 239.255.70.83.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Before using this command, enable CFS distribution over IPv4 using the cfs ipv4 distribute command.
All CFS over IP enabled switches with similar multicast addresses form one CFS over IP fabric. CFS protocol-specific distributions, such as the keepalive mechanism for detecting network topology changes, use the IP multicast address to send and receive information.
CFS distributions for application data use directed unicast.
You can configure a value for a CFS over IP multicast address. The default IPv4 multicast address is 239.255.70.83.
Examples
The following example shows how to configure an IP multicast address for CFS over IPv4:
switch(config)# cfs ipv4 mcast-address 239.255.1.1
Distribution over this IP type will be affected
Change multicast address for CFS-IP ?
Are you sure? (y/n) [n] y
The following example shows how to revert to the default IPv4 multicast address for CFS distribution over IPv4:
switch(config)# no cfs ipv4 mcast-address 10.1.10.100
Distribution over this IP type will be affected
Change multicast address for CFS-IP ?
Are you sure? (y/n) [n] y
Related Commands
Command
|
Description
|
cfs ipv4 distribute
|
Enables or disables Cisco Fabric Services (CFS) distribution over IPv4.
|
show cfs status
|
Displays whether CFS distribution is enabled or disabled.
|
cfs ipv6 distribute
To enable Cisco Fabric Services (CFS) distribution over IPv6 for applications using CFS, use the cfs ipv6 distribute command. To disable this feature, use the no form of the command.
cfs ipv6 distribute
no cfs ipv6 distribute
Syntax Description
This command has no arguments or keywords.
Command Default
CFS distribution is enabled. CFS over IPv4 is disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
All CFS over IP enabled switches with similar multicast addresses form one CFS over IP fabric. CFS protocol-specific distributions, such as the keepalive mechanism for detecting network topology changes, use the IP multicast address to send and receive information.
Observe the following guidelines when using this command:
•
If a switch is reachable over both IP and Fibre Channel, application data will be distributed over Fibre Channel.
•
You can select either an IPv4 or IPv6 distribution when CFS is enabled over IP.
•
Both IPv4 and IPv6 distribution cannot be enabled on the same switch.
•
A switch that has IPv4 distribution enabled cannot detect a switch that IPv6 distribution enabled. The switches operate as if they are in two different fabrics even though they are connected to each other.
Examples
The following example shows how to disable CFS IPv6 distribution:
switch(config)# no cfs ipv6 distribute
This will prevent CFS from distributing over IPv6 network.
Are you sure? (y/n) [n]
The following example shows how to reenable CFS IPv6 distribution:
switch(config)# cfs ipv6 distribute
Related Commands
Command
|
Description
|
cfs ipv6 mcast-address
|
Configures an IPv6 multicast address for Cisco Fabric Services (CFS) distribution over IPv6.
|
show cfs status
|
Displays whether CFS distribution is enabled or disabled.
|
cfs ipv6 mcast-address
To configure an IPv6 multicast address for Cisco Fabric Services (CFS) distribution over IPv6, use the cfs ipv6 mcast-address command. To disable this feature, use the no form of the command.
cfs ipv6 mcast-address ipv6-address
no cfs ipv6 mcast-address ipv6-address
Syntax Description
ipv6-address
|
Specifies an IPv6 multicast address or CFS distribution over IPv6. The IPv6 Admin scope range is [ff15::/16, ff18::/16].
|
Command Default
Multicast address: ff15::efff:4653.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Before using this command, enable CFS distribution over IPv6 using the cfs ipv6 distribute command.
All CFS over IP enabled switches with similar multicast addresses form one CFS over IP fabric. CFS protocol-specific distributions, such as the keepalive mechanism for detecting network topology changes, use the IP multicast address to send and receive information. CFS distributions for application data use directed unicast.
You can configure a CFS over IP multicast address value for IPv6. The default IPv6 multicast address is ff15::efff:4653. Examples of the IPv6 Admin scope range are ff15::0000:0000 to ff15::ffff:ffff and ff18::0000:0000 to ff18::ffff:ffff.
Examples
The following example shows how to configure an IP multicast address for CFS over IPv6:
switch(config)# cfs ipv6 mcast-address ff13::e244:4754
Distribution over this IP type will be affected
Change multicast address for CFS-IP ?
Are you sure? (y/n) [n] y
The following example shows how to revert to the default IPv6 multicast address for CFS distribution over IPv6:
switch(config)# no cfs ipv6 ff13::e244:4754
Distribution over this IP type will be affected
Change multicast address for CFS-IP ?
Are you sure? (y/n) [n] y
Related Commands
Command
|
Description
|
cfs ipv6 distribute
|
Enables or disables Cisco Fabric Services (CFS) distribution over IPv6.
|
show cfs status
|
Displays whether CFS distribution is enabled or disabled.
|
cfs region
To create a region that restricts the scope of application distribution to the selected switches, use the cfs region command. To disable this feature, use the no form of this command.
cfs region region-id
no cfs region region-id
Syntax Description
region-id
|
Specifies the region identifier. The range is from 1 to 255. A total of 200 regions are supported.
|
Command Default
The default region identifier is 0.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
An application can only be a part of one region on a given switch. By creating the region ID and assigning it to an application, the application distribution is restricted to switches with a similar region ID.
Cisco Fabric Services (CFS) regions provide the ability to create distribution islands within the application scope. Currently, the regions are supported only for physical scope applications. In the absence of any region configuration, the application will be a part of the default region. The default region is region ID 0.
Examples
The following example shows how to create a region ID:
switch(config)# cfs region 1
The following example shows how to assign an application to a region:
switch(config)# cfs region 1
switch(config-cfs-region)# ntp
The following example shows how to remove an application assigned to a region:
switch# cfs region 1
switch(config-cfs-region)# no ntp
Related Commands
Command
|
Description
|
show cfs regions
|
Displays all configured applications with peers.
|
cfs staggered-merge
CFS can merge the data from multiple VSANs. To disable this feature, use the no form of this command.
cfs staggered-merge enable
no cfs staggered-merge enable
Syntax Description
enable
|
Enables the CFS staggered-merge option.
|
Command Default
Staggered merge is disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to enable CFS staggered merge:
switch(config)# cfs staggered-merge enable
Related Commands
Command
|
Description
|
show cfs status
|
Displays whether staggered merge is enabled.
|
clear device-alias
To clear device alias information, use the clear device-alias command.
clear device-alias {database | session | statistics}
Syntax Description
database
|
Clears the device alias database.
|
session
|
Clears session information.
|
statistics
|
Clears device alias statistics.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear the device alias session:
switch# clear device-alias session
Related Commands
Command
|
Description
|
show device-alias
|
Displays device alias database information.
|
clear fcdomain
To clear the entire list of configured hosts, use the clear fcdomain command.
clear fcdomain session vsan vsan-id
Syntax Description
session
|
Clears session information.
|
vsan vsan-id
|
Clears Fibre Channel domains for a specified VSAN ranging from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command clears only the list of configured hosts. Existing connections are not terminated.
Examples
The following example shows how to clear the entire list of configured hosts for remote capture:
Related Commands
Command
|
Description
|
show fcdomain
|
Displays the list of hosts configured for a remote capture.
|
clear fcflow stats
To clear Fibre Channel flow statistics, use the clear fcflow stats command.
clear fcflow stats [aggregated] index flow-index
Syntax Description
aggregated
|
(Optional) Clears the Fibre Channel flow aggregated statistics.
|
index
|
Clears the Fibre Channel flow counters for a specified flow index.
|
flow-index
|
Specifies the flow index number.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear aggregated Fibre Channel flow statistics for flow index 1:
switch(config)# clear fcflow stats aggregated index 1
Related Commands
Command
|
Description
|
show fcflow
|
Displays the fcflow statistics.
|
clear fcns statistics
To clear the name server statistics, use the clear fcns statistics command.
clear fcns statistics vsan vsan-id
Syntax Description
vsan vsan-id
|
Clears the FCS statistics for a specified VSAN ranging from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear the name server statistics:
switch# clear fcns statistics vsan 1
Related Commands
Command
|
Description
|
show fcns statistics
|
Displays the name server statistics.
|
clear fcsm log
To clear the FCSM log, use the clear fcsm log command.
clear fcsm log
Syntax Description
This command has no arguments or keywords.
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear the FSCM log:
Related Commands
Command
|
Description
|
show fcs
|
Displays the fabric configuration server information.
|
clear fcs statistics
To clear the fabric configuration server statistics, use the clear fcs statistics command.
clear fcs statistics vsan vsan-id
Syntax Description
vsan vsan-id
|
Clears the FCS statistics for a specified VSAN ranging from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear the fabric configuration server statistics for VSAN 10:
switch# clear fcs statistics vsan 10
Related Commands
Command
|
Description
|
show fcs statistics
|
Displays the fabric configuration server statistics information.
|
clear fctimer session
To clear fctimer Cisco Fabric Services (CFS) session configuration and locks, use the clear fctimer session command.
clear fctimer session
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear an fctimer session:
switch# clear fctimer session
Related Commands
Command
|
Description
|
show fctimer
|
Displays fctimer information.
|
clear fspf counters
To clear the Fabric Shortest Path First (FSPF) statistics, use the clear fspf counters command.
clear fspf counters vsan vsan-id [interface type]
Syntax Description
vsan
|
Indicates that the counters are to be cleared for a VSAN.
|
vsan-id
|
The ID of the VSAN is from 1 to 4093.
|
interface type
|
(Optional). The counters are to be cleared for an interface. The interface types are fc (Fibre Channel) and san-port-channel (SAN port channel).
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
If the interface is not specified, then all of the counters of a VSAN are cleared. If the interface is specified, then the counters of the specific interface are cleared.
Examples
The following example clears the FSPF statistics on VSAN 1:
switch# clear fspf counters vsan 1
The following example clears FSPF statistics in VSAN 1 for the specified Fibre Channel interface:
switch# clear fspf counters vsan 1 interface fc 3/2
Related Commands
Command
|
Description
|
show fspf
|
Displays global FSPF information for a specific VSAN.
|
clear port-security
To clear the port security information on the switch, use the clear port-security command.
clear port-security {database auto-learn {interface fc slot/port | san-port-channel port} |
session | statistics} vsan vsan-id
Syntax Description
database
|
Clears the port security active configuration database.
|
session
|
Clears the port security CFS configuration session and locks.
|
statistics
|
Clears the port security counters.
|
auto-learn
|
Clears the automatically learned entries for a specified interface or VSAN.
|
interface fc slot/port
|
Clears entries for the specified Fibre Channel interface.
|
san-port-channel port
|
Clears entries for a specified SAN port channel. The range is 1 to 128.
|
vsan vsan-id
|
Clears entries for a specified VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The active database is read-only and the clear port-security database command can be used when resolving conflicts.
Examples
The following example clears all existing statistics from the port security database for a specified VSAN:
switch# clear port-security statistics vsan 1
The following example clears learned entries in the active database for a specified interface within a VSAN:
switch# clear port-security database auto-learn interface fc2/1 vsan 1
The following example clears learned entries in the active database up to for the entire VSAN:
switch# clear port-security database auto-learn vsan 1
Related Commands
Command
|
Description
|
show port-security
|
Displays the configured port security information.
|
clear rlir
To clear Registered Link Incident Report (RLIR) information, use the clear rlir command.
clear rlir {history | recent {interface fc slot/port | portnumber port} | statistics vsan vsan-id}
Syntax Description
history
|
Clears RLIR incident link history.
|
recent
|
Clears recent link incidents
|
interface fc slot/port
|
Clears entries for the specified interface
|
portnumber port
|
Displays the port number for the link incidents
|
statistics
|
Clears the RLIR statistics.
|
vsan vsan-id
|
Clears the RLIR statistics for a VSAN. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear RLIR statistics for VSAN 1:
switch# clear rlir statistics vsan 1
Related Commands
Command
|
Description
|
show rlir
|
Displays RLIR information.
|
clear rscn session
To clear a Registered State Change Notification (RSCN) session for a specified VSAN, use the clear rscn session command.
clear rscn session vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN where the RSCN session should be cleared. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example clears an RSCN session on VSAN 1:
switch# clear rscn session vsan 1
Related Commands
Command
|
Description
|
rscn
|
Configures an RSCN.
|
show rscn
|
Displays RSCN information.
|
clear rscn statistics
To clear the registered state change notification statistics for a specified VSAN, use the clear rscn statistics command.
clear rscn statistics vsan vsan-id
Syntax Description
vsan
|
Clears the RSCN statistics for a VSAN.
|
vsan-id
|
The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to clear RSCN statistics for VSAN 1:
switch# clear rscn statistics vsan 1
Related Commands
Command
|
Description
|
show rscn
|
Displays RSCN information.
|
clear zone
To clear all configured information in the zone server for a specified VSAN, use the clear zone command.
clear zone {database | lock | statistics} vsan vsan-id
Syntax Description
database
|
Clears zone server database information.
|
lock
|
Clears a zone server database lock.
|
statistics
|
Clears zone server statistics.
|
vsan
|
Clears zone information for a VSAN.
|
vsan-id
|
The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
After entering a clear zone database command, you need to explicitly enter the copy running-config startup-config to ensure that the running configuration is used when you next start the switch.
When you enter the clear zone lock command from a remote switch, only the lock on that remote switch is cleared. When you enter the clear zone lock command from the switch where the lock originated, all locks in the VSAN are cleared. The recommended method to clear a session lock on a switch where the lock originated is by entering the no zone commit vsan command.
Examples
The following example shows how to clear all configured information in the zone server for VSAN 1:
switch# clear zone database vsan 1
Related Commands
Command
|
Description
|
show zone
|
Displays zone information for any configured interface.
|
device-alias abort
To discard a Distributed Device Alias Services (device alias) Cisco Fabric Services (CFS) distribution session in progress, use the device-alias abort command.
device-alias abort
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to discard a device alias CFS distribution session in progress:
switch(config)# device-alias abort
Related Commands
Command
|
Description
|
device-alias database
|
Configures and activates the device alias database.
|
device-alias distribute
|
Enables CFS distribution for device aliases.
|
show device-alias
|
Displays device alias information.
|
device-alias commit
To apply the pending configuration pertaining to the Distributed Device Alias Services (device alias) Cisco Fabric Services (CFS) distribution session in progress in the fabric, use the device-alias commit command.
device-alias commit
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to commit pending changes to the active DPVM database:
switch(config)# device-alias commit
Related Commands
Command
|
Description
|
device-alias database
|
Configures and activates the device alias database.
|
device-alias distribute
|
Enables CFS distribution for device aliases.
|
show device-alias
|
Displays device alias information.
|
device-alias database
To initiate a Distributed Device Alias Services (device alias) session and configure the device alias database, use the device-alias database command. To deactivate the device alias database, use the no form of the command.
device-alias database
no device-alias database
Syntax Description
This command has no other arguments or keywords.
Command Default
Deactivated.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Usage Guidelines
The device-alias database command starts a device alias session that locks all the databases on all the switches in this fabrics. When you exit device alias database configuration mode, the device alias session ends and the locks are released.
You can only perform all modifications in the temporary device alias database. To make the changes permanent, use the device-alias commit command.
Examples
The following example shows how to activate a device alias session and enter device alias database configuration mode;
switch(config)# device-alias database
switch(config-device-alias-db)#
Related Commands
Command
|
Description
|
device-alias commit
|
Commits changes to the temporary device alias database to the active device alias database.
|
show device-alias
|
Displays device alias database information.
|
device-alias distribute
To enable Cisco Fabric Services (CFS) distribution for Distributed Device Alias Services (device alias), use the device-alias distribute command. To disable this feature, use the no form of the command.
device-alias distribute
no device-alias distribute
Syntax Description
This command has no other arguments or keywords.
Command Default
Enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Usage Guidelines
Use the device-alias commit command to apply pending changes to the CFS distribution session.
Examples
The following example shows how to enable distribution for device alias information:
switch(config)# device-alias distribute
Related Commands
Command
|
Description
|
device-alias commit
|
Commits changes to the active device alias database.
|
device-alias database
|
Configures and activates the device alias database.
|
show device-alias
|
Displays device alias information.
|
device-alias import fcalias
To import device alias database information from another VSAN, use the device-alias import fcalias command. To revert to the default configuration or factory defaults, use the no form of the command.
device-alias import fcalias vsan vsan-id
no device-alias import fcalias vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Usage Guidelines
You can import legacy device name configurations using this feature without losing data, if they satisfy the following restrictions:
•
Each fcalias has only one member.
•
The member type is supported by the device name implementation.
If any name conflict exists, the fcaliases are not imported. The device name database is completely independent from the VSAN dependent fcalias database.
When the import operation is complete, the modified global fcalias table can distributed to all other switches in the physical fabric using the device-alias distribute command so that new definitions are available everywhere.
Examples
The following example shows how to import device alias information:
switch(config)# device-alias import fcalias vsan 10
Related Commands
Command
|
Description
|
device-alias database
|
Configures and activates the device alias database.
|
device-alias distribute
|
Distributes fcalias database changes to the fabric.
|
show device-alias
|
Displays device alias database information.
|
device-alias mode
To configure device alias enhanced mode, use the device-alias mode command. To remove device alias enhanced mode, use the no form of the command.
device-alias mode enhanced
no device-alias mode enhanced
Syntax Description
enhanced
|
Specifies enhanced mode.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to device alias enhanced mode:
switch(config)# device-alias mode enhanced
Related Commands
Command
|
Description
|
device-alias database
|
Enters device alias database configuration mode.
|
show device-alias
|
Displays device alias database information.
|
device-alias name
To configure device names in the device alias database, use the device-alias name command. To remove device names from the device alias database, use the no form of the command.
device-alias name device-name pwwn pwwn-id
no device-alias name device-name
Syntax Description
device-name
|
Specifies the device name. Maximum length is 64 characters.
|
pwwn pwwn-id
|
Specifies the pWWN ID. The format is hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal number.
|
Command Default
None
Command Modes
Device alias database configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to configure a device name alias entry in the device name database:
switch(config)# device-alias database
switch(config-device-alias-db)# device-alias name Device1 pwwn 21:00:00:20:37:6f:db:bb
Related Commands
Command
|
Description
|
device-alias database
|
Enters device alias database configuration mode.
|
show device-alias
|
Displays device alias database information.
|
device-alias rename
To configure device names in the device alias database, use the device-alias rename command. To remove device names from the device alias database, use the no form of the command.
device-alias rename device-name1 device-name2
no device-alias rename device-name
Syntax Description
device-name1
|
Specifies the current device name.
|
device-name2
|
Specifies the new device name. Maximum length is 64 characters.
|
Command Default
None
Command Modes
Device alias database configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to configure a device name alias entry in the device name database:
switch(config)# device-alias database
switch(config-device-alias-db)# device-alias rename Device1 Device2
Related Commands
Command
|
Description
|
device-alias database
|
Enters device alias database configuration mode.
|
show device-alias
|
Displays device alias database information.
|
discover custom-list
To selectively initiate discovery for specified domain IDs in a VSAN, use the discover custom-list command.
discover custom-list {add | delete} vsan vsan-id domain domain-id
Syntax Description
add
|
Adds a targets to the customized list.
|
delete
|
Deletes a target from the customized list.
|
vsan vsan-id
|
Discovers SCSI targets for the specified VSAN ID. The range is 1 to 4093.
|
domain domain-id
|
Discovers SCSI targets for the specified domain ID. The range is 1 to 239.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example selectively initiates discovery for the specified VSAN and domain ID:
switch# discover custom-list add vsan 1 domain 2
The following example deletes the specified VSAN and domain ID from the customized list:
switch# discover custom-list delete vsan 1 domain 2
discover scsi-target
To discover SCSI targets on local storage to the switch or remote storage across the fabric, use the discover scsi-target command.
discover scsi-target {custom-list | local | remote | vsan vsan-id fcid fc-id} os {aix | all | hpux |
linux | solaris | windows} [lun | target]
Syntax Description
custom-list
|
Discovers SCSI targets from the customized list.
|
local
|
Discovers local SCSI targets.
|
remote
|
Discovers remote SCSI targets.
|
vsan vsan-id
|
Discovers SCSI targets for the specified VSAN ID. The range is 1 to 4093.
|
fcid fc-id
|
Discovers SCSI targets for the specified FCID. The format is 0xhhhhhhh, where h is a hexadecimal digit.
|
os
|
Discovers the specified operating system.
|
aix
|
Discovers the AIX operating system
|
all
|
Discovers all operating systems
|
hpux
|
Discovers the HPUX operating system
|
linux
|
Discovers the Linux operating system
|
solaris
|
Discovers the Solaris operating system
|
windows
|
Discovers the Windows operating system
|
lun
|
(Optional) Discovers SCSI targets and LUNs.
|
target
|
(Optional) Discovers SCSI targets.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to discover local targets assigned to all OSs:
switch# discover scsi-target local os all
discovery started
The following example shows how to discover remote targets assigned to the Windows OS:
switch# discover scsi-target remote os windows
discovery started
The following example shows how to discover SCSI targets for the specified VSAN (1) and FCID (0x9c03d6):
switch# discover scsi-target vsan 1 fcid 0x9c03d6 os aix
discover scsi-target vsan 1 fcid 0x9c03d6
VSAN: 1 FCID: 0x9c03d6 PWWN: 00:00:00:00:00:00:00:00
PRLI RSP: 0x01 SPARM: 0x0012...
The following example begins discovering targets from a customized list assigned to the Linux operating system:
switch# discover scsi-target custom-list os linux
discovery started
fabric profile
To utilize a preset QoS setting, use the fabric profile command. To restore the default, use the no form of the command.
fabric profile {reliable-multicast | unicast-optimized}
no fabric profile
Syntax Description
reliable-multicast
|
Optimizes the QoS parameters in the fabric to ensure reliable delivery of multicast traffic.
|
unicast-optimized
|
Optimizes the QoS parameters in the fabric for unicast traffic.
|
Command Default
Unicast-optimized.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example sets the fabric to ensure reliable delivery of multicast traffic:
switch(config)# fabric profile reliable-multicast
The following example sets the fabric profile to the default value:
switch(config)# no fabric profile
Related Commands
Command
|
Description
|
show fabric profile
|
Displays the current setting of the fabric.
|
fabric-binding activate
To activate fabric binding in a VSAN, use the fabric-binding activate command. To disable this feature, use the no form of the command.
fabric-binding activate vsan vsan-id [force]
no fabric-binding activate vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN. The ID of the VSAN is from 1 to 4093.
|
force
|
(Optional) Forces fabric binding activation.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example activates the fabric binding database for the specified VSAN:
switch(config)# fabric-binding activate vsan 1
The following example deactivates the fabric binding database for the specified VSAN:
switch(config)# no fabric-binding activate vsan 10
The following example forcefully activates the fabric binding database for the specified VSAN
switch(config)# fabric-binding activate vsan 3 force
The following example reverts to the previously configured state or to the factory default (if no state is configured):
switch(config)# no fabric-binding activate vsan 1 force
Related Commands
Command
|
Description
|
fabric-binding database
|
Configures a fabric-binding database.
|
fabric-binding enable
|
Enables fabric-binding.
|
fabric-binding database copy
To copy from the active fabric binding database to the configuration fabric binding database, use the fabric-binding database copy command.
fabric-binding database copy vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Fabric binding is configured on a per-VSAN basis and can be implemented in both FICON VSANs and Fibre Channel VSANs.
If the configured database is empty, this command is not accepted.
Examples
The following example copies from the active database to the configuration database in VSAN 1:
switch# fabric-binding database copy vsan 1
Related Commands
Command
|
Description
|
fabric-binding diff
|
Provides the differences between the fabric-binding databases.
|
fabric-binding database diff
To view the differences between the active database and the configuration database in a VSAN, use the fabric-binding database diff command.
fabric-binding database diff {active | config} vsan vsan-id
Syntax Description
active
|
Provides information about the differences in the active database relating to the configuration database.
|
config
|
Provides information about information on the differences in the configuration database relating to the active database.
|
vsan vsan-id
|
Specifies the VSAN. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Fabric binding is configured on a per-VSAN basis and can be implemented in both FICON VSANs and Fibre Channel VSANs.
Examples
The following example displays the differences between the active database and the configuration database in VSAN 1:
switch# fabric-binding database diff active vsan 1
The following example displays information about the differences between the configuration database and the active database:
switch# fabric-binding database diff config vsan 1
Related Commands
Command
|
Description
|
fabric-binding copy
|
Copies from the active to the configuration fabric binding database.
|
fabric-binding database vsan
To configure a user-specified fabric binding list in a VSAN, use the fabric-binding database vsan command. To disable the fabric binding, use the no form of the command.
fabric-binding database vsan vsan-id
swwn switch-wwn domain domain-id
fabric-binding database vsan vsan-id
no swwn switch-wwn domain domain-id
no fabric-binding database vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN. The ID of the VSAN is from 1 to 4093.
|
swwn switch-wwn
|
Configures the switch WWN in dotted hex format.
|
domain domain-id
|
Specifies the specified domain ID. The domain ID is a number from 1 to 239.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Fabric binding is configured on a per-VSAN basis. In a Fibre Channel VSAN, only the switch world wide name (sWWN_ is required; the domain ID is optional.
A user-specified fabric binding list contains a list of switch WWNs (sWWNs) within a fabric. If an sWWN attempts to join the fabric and that sWWN is not on the list, or the sWWN is using a domain ID that differs from the one specified in the allowed list, the ISL between the switch and the fabric is automatically isolated in that VSAN and the switch is denied entry into the fabric.
Examples
The following example enters the fabric binding database mode and adds the sWWN and domain ID of a switch to the configured database list:
switch(config)# fabric-binding database vsan 5
switch(config-fabric-binding)# swwn 21:00:05:30:23:11:11:11 domain 102
The following example deletes a fabric binding database for the specified VSAN:
switch(config)# no fabric-binding database vsan 10
The following example deletes the sWWN and domain ID of a switch from the configured database list:
switch(config)# fabric-binding database vsan 5
switch(config-fabric-binding)# no swwn 21:00:15:30:23:1a:11:03 domain 101
Related Commands
Command
|
Description
|
fabric-binding activate
|
Activates fabric-binding.
|
fabric-binding enable
|
Enables fabric-binding.
|
fabric-binding enable
To enable fabric binding in a VSAN, use the fabric-binding enable command. To disable fabric binding, use the no form of the command.
fabric-binding enable
no fabric-binding enable
Syntax Description
This command has no other arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Fabric binding is configured on a per-VSAN basis.
The fabric binding feature must be enabled in each switch in the fabric that participate in the fabric binding.
Examples
The following example enables fabric binding on that switch:
switch(config)# fabric-binding enable
The following example disables fabric binding on that switch:
switch(config)# no fabric-binding enable
Related Commands
Command
|
Description
|
fabric-binding activate
|
Activates fabric-binding.
|
fabric-binding database
|
Configures a fabric-binding database.
|
fcalias clone
To clone a Fibre Channel alias, use the fcalias clone command.
fcalias clone origFcalias-Name cloneFcalias-Name vsan vsan-id
Syntax Description
origFcalias-Name cloneFcalias-Name
|
Clones a Fibre Channel alias from the current name to a new name. Maximum length of names is 64 characters.
|
vsan
|
The clone Fibre Channel alias is for a VSAN.
|
vsan-id
|
The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
To disable a Fibre Channel alias, use the no form of the fcalias name command.
Examples
The following example shows how to clone a fcalias named origAlias to cloneAlias on VSAN 45:
switch(config)# fcalias clone origAlias cloneAlias vsan 45
Related Commands
Command
|
Description
|
show fcalias
|
Displays the member name information in a Fibre Channel alias (fcalias).
|
fcalias name
To configure a Fibre Channel alias, use the fcalias name command. To disable a Fibre Channel alias, use the no form of the command.
fcalias name alias-name vsan vsan-id
no fcalias name alias-name vsan vsan-id
Syntax Description
alias-name
|
The name of the fcalias. Maximum length is 64 characters.
|
vsan
|
The fcalias is for a VSAN.
|
vsan-id
|
The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
To include multiple members in any alias, use the FCID, fWWN, or pWWN values.
Examples
The following example shows how to configure an fcalias called AliasSample on VSAN 3:
switch(config)# fcalias name AliasSample vsan 3
Related Commands
Command
|
Description
|
member (fcalias configuration mode)
|
Configures alias members for a specified zone.
|
fcalias rename
To rename a Fibre Channel alias (fcalias), use the fcalias rename command.
fcalias rename current-name new-name vsan vsan-id
no fcalias rename current-name new-name vsan vsan-id
Syntax Description
current-name
|
Specifies the current fcalias name. The maximum length is 64.
|
new-name
|
Specifies the new fcalias name. The maximum length is 64.
|
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to rename an fcalias:
switch(config)# fcalias rename oldalias newalias vsan 10
Related Commands
Command
|
Description
|
fcalias name
|
Configures fcalias names.
|
show fcalias
|
Displays fcalias information.
|
fcdomain
To configure the Fibre Channel domain feature, use the fcdomain command. To disable the Fibre Channel domain, use the no form of the command.
fcdomain {allowed domain vsan vsan-id | auto-reconfigure vsan vsan-id | contiguous-allocation
vsan vsan-id | domain id {preferred | static} vsan vsan-id | fabric-name name vsan vsan-id |
fcid {database | persistent vsan vsan-id} | optimize fast-restart vsan vsan-id | priority value
vsan vsan-id | restart [disruptive] vsan vsan-id | vsan vsan-id}
no fcdomain {allowed domain vsan vsan-id | auto-reconfigure vsan vsan-id |
contiguous-allocation vsan vsan-id | domain id {preferred | static} vsan vsan-id |
fabric-name name vsan vsan-id | fcid {database | persistent vsan vsan-id} | optimize
fast-restart vsan vsan-id | priority value vsan vsan-id | restart [disruptive] vsan vsan-id |
vsan vsan-id}
Syntax Description
allowed domain
|
Configures the allowed domain ID list ranging from 1 to 239.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
auto-reconfigure
|
Configures autoreconfigure.
|
contiguous-allocation
|
Configures contiguous allocation.
|
domain id
|
Configures the domain ID and its type. The range is 0 to 239.
|
preferred
|
Configures the domain ID as preferred. By default, the local switch accepts the domain ID assigned by the principal switch and the assigned domain ID becomes the runtime domain ID.
|
static
|
Configures the domain ID as static. The assigned domain ID is discarded, all local interfaces are isolated, and the local switch assigns itself the configured domain ID, which becomes the runtime domain ID.
|
fabric-name name
|
Specifies the fabric name. The name format is hh:hh:hh:hh:hh:hh:hh:hh.
|
fcid
|
Configures Fibre Channel domain persistent FC IDs.
|
database
|
Enters persistent FC IDs mode.
|
persistent
|
Enables or disables Fibre Channel domain persistent FC IDs.
|
optimize fast-restart
|
Enables a domain manager fast restart on a specified VSAN.
|
priority value
|
Specifies the Fibre Channel domain priority. The range is 1 to 254.
|
restart
|
Starts a disruptive or nondisruptive reconfiguration.
|
disruptive
|
(Optional) Forces the disruptive fabric reconfiguration.
|
Command Default
Enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
You can use this command to select the principal switch, configure domain ID distribution, reconfigure the fabric, and allocate FC IDs.
We recommend using the optimize fast-restart option on most fabrics, especially those with a large number of logical ports (3200 or more), where a logical port is an instance of a physical port in a VSAN.
Examples
The following example shows how to configure a preferred domain ID for VSAN 87:
switch(config)# fcdomain domain 3 preferred vsan 87
The following example shows how to specify disruptive fabric reconfiguration for VSAN 1:
switch(config)# fcdomain restart disruptive vsan 1
The following example shows how to enable domain manager fast restart for VSANs 7 through 10:
switch(config)# fcdomain optimize fast-restart vsan 7 - 10
The following example shows how configure the fabric world wide name (fWWN) for VSAN3:
switch(config)# fcdomain fabric-name 20:1:ac:16:5e:0:21:01 vsan 3
Related Commands
Command
|
Description
|
show fcdomain
|
Displays global information about the Fibre Channel domain configurations.
|
fcdomain abort vsan
To flush cached data without committing and release the lock, use the fcdomain abort vsan command. To disable the flushing of cached data, use the no form of the command.
fcdomain abort vsan vsan-id
no fcdomain abort vsan vsan-id
Syntax Description
vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
Enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to flush cached data:
switch(config)# fcdomain abort vsan 10
Related Commands
Command
|
Description
|
fcdomain
|
Configures Fibre Channel domain features.
|
fcdomain commit vsan
|
Commits cached data and releases the lock.
|
show fcdomain
|
Displays global information about the Fibre Channel domain configurations.
|
fcdomain commit vsan
To commit cached data and release the lock, use the fcdomain commit vsan command. To release the lock without committing the cached data, use the no form of the command.
fcdomain commit vsan vsan-id
no fcdomain commit vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
Enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to commit cached data:
switch(config)# fcdomain commit vsan 10
Related Commands
Command
|
Description
|
fcdomain
|
Configures Fibre Channel domain features.
|
fcdomain abort vsan
|
Flushes cached data without committing and releases the lock.
|
show fcdomain
|
Displays global information about the Fibre Channel domain configurations.
|
fcdomain distribute
To enable fabric distribution using Cisco Fabric Services (CFS), use the fcdomain distribute command. To disable fabric distribution using CFS, us the no form of the command.
fcdomain distribute
no fcdomain distribute
Syntax Description
This command has no arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example enables fabric distribution using CFS:
switch(config)# fcdomain distribute
The following example disables fabric distribution using CFS:
switch(config)# no fcdomain distribute
Related Commands
Command
|
Description
|
fcdomain
|
Configures Fibre Channel domain features.
|
show fcdomain
|
Displays global information about the Fibre Channel domain configurations.
|
fcdomain rcf-reject
To enable the RCF reject flag for a Fibre Channel interface, use the fcdomain option. To disable this feature, use the no form of the command.
fcdomain rcf-reject vsan vsan-id
no fcdomain rcf-reject vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
Enabled.
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Use this option to configure the RCF reject option for the selected Fibre Channel or virtual Fibre Channel interface.
Examples
The following example shows how to configure the FCIP RCF reject fcdomain feature on a virtual Fibre Channel interface:
switch(config)# interface vfc 3
switch(config-if)# fcdomain rcf-reject vsan 1
Related Commands
Command
|
Description
|
show fcdomain
|
Displays global information about the Fibre Channel domain configurations.
|
show interface fc
|
Displays an interface configuration for a specified Fibre Channel interface.
|
fcdroplatency
To configure the network and switch Fibre Channel drop latency time, use the fcdroplatency command. To disable the Fibre Channel latency time, use the no form of the command.
fcdroplatency {network milliseconds [vsan vsan-id] | switch milliseconds}
no fcdroplatency {network milliseconds [vsan vsan-id] | switch milliseconds}
Syntax Description
network milliseconds
|
Specifies network latency. The range is 500 to 60000.
|
vsan vsan-id
|
(Optional) Specifies a VSAN ID. The range is 1 to 4093.
|
switch milliseconds
|
Specifies switch latency. The range is 0 to 60000 milliseconds.
|
Command Default
2000 millisecond network latency.
500 millisecond switch latency.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to configure the network latency to 5000 milliseconds:
switch(config)# fcdroplatency network 5000
The following example shows how to revert to the default switch latency:
switch(config)# no fcdroplatency switch 4000
Related Commands
Command
|
Description
|
show fcdroplatency
|
Displays the configured Fibre Channel drop latency parameters.
|
fcflow stats
To configure fcflow statistics, use the fcflow stats command. To disable the counter, use the no form of the command.
fcflow stats {aggregated index flow-number vsan vsan-id | index flow-number destination-fcid
source-fcid netmask vsan vsan-id}
no fcflow stats {aggregated index flow-number | index flow-number}
Syntax Description
aggregated
|
Configures aggregated fcflow statistics.
|
index flow-number
|
Specifies a flow index. The range is 1 to 2147483647.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
destination-fcid
|
Enters the destination FCID in hexadecimal format.
|
source-fcid
|
Enters the source FCID in hexadecimal format.
|
netmask
|
Enters the mask for the source and destination FCID (restricted to 6 hexadecimal characters ranging from 0xff0000 to 0xffffff).
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
If you enable flow counters, you can enable a maximum of 1024 entries for aggregate flow and flow statistics. Be sure to assign an unused flow index or each new flow. The number space for flow index is shared between the aggregate flow statistics and the flow statistics.
Examples
The following example enables the aggregated flow counter:
switch(config)# fcflow stats aggregated index 1005 vsan 1
The following example disables the aggregated flow counter:
switch(config)# no fcflow stats aggregated index 1005
The following example enables the flow counter for a specific flow:
switch(config)# fcflow stats index 1 0x145601 0x5601 0xffffff vsan 1
The following example disables the flow counter for index 1001:
switch(config)# no fcflow stats index 1001
Related Commands
Command
|
Description
|
show fcflow stats
|
Displays the configured Fibre Channel drop latency parameters.
|
fcid-allocation
Use the fcid-allocation command to manually add a FCID to the default area company ID list. Use the no form of the command to remove a FCID from the default area company ID list.
fcid-allocation area company-id company-id
no fcid-allocation area company-id company-id
Syntax Description
area
|
Modifies the auto area list of company IDs.
|
company-id company-id
|
Configures the company IDs.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Fibre Channel standards require a unique FCID to be allocated to an N port attached to a Fx port in any switch. To conserve the number of FCIDs used, Cisco Nexus 5000 Series switches use a special allocation scheme.
Some HBAs do not discover targets that have FC IDs with the same domain and area. The switch software maintains a list of tested company IDs that do not exhibit this behavior. These HBAs were allocated with single FC IDs, and for others a full area was allocated.
To allow further scalability for switches with numerous ports, the switch software maintains a list of HBAs exhibiting this behavior. Each HBA is identified by its company ID (also known as Organizational Unique Identifier, or OUI) used in the pWWN during a fabric log in. A full area is allocated to the N ports with company IDs that are listed and for the others, a single FC ID is allocated. Regardless of the type (whole area or single) of FC ID allocated, the FC ID entries remain persistent.
Examples
The following example adds a new company ID to the default area company ID list:
switch(config)# fcid allocation area company-id 0x003223
fcinterop fcid-allocation
To allocate FCIDs on the switch, use the fcinterop fcid-allocation command. To disable FCIDs on the switch, use the no form of the command.
fcinterop fcid-allocation {auto | flat | none}
no fcinterop fcid-allocation {auto | flat | none}
Syntax Description
auto
|
Assigns single FCID to compatible HBAs.
|
flat
|
Assign single FCID.
|
none
|
Assigns FCID range.
|
Command Default
The default is automatic allocation of FCIDs.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command defines how the switch assigns FCIDs.
Examples
The following example sets the FCID allocation to flat:
switch(config)# fcinterop fcid-allocation flat
Related Commands
Command
|
Description
|
show flogi database
|
Displays the fabric login (FLOGI) table.
|
fcns no-auto-poll
To enable or disable automatic polling in the name server database, use the fcns no-auto-poll command.
fcns no-auto-poll [vsan vsan-id] | [wwn wwn-id]
no fcns no-auto-poll [vsan vsan-id] | [wwn wwn-id]
Syntax Description
vsan vsan-id
|
(Optional) Specifies a VSAN ID. The range is 1 to 4093.
|
wwn wwn-id
|
(Optional) Specifies the port WWN, with the format hh:hh:hh:hh:hh:hh:hh:hh.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to disable automatic polling for VSAN 2:
switch(config)# fcns no-auto-poll vsan 2
Related Commands
Command
|
Description
|
show fcns
|
Displays the name server database and statistical information for a specified VSAN or for all VSANs.
|
fcns proxy-port
To register a name server proxy, use the fcns proxy-port command.
fcns proxy-port wwn-id vsan vsan-id
no fcns proxy-port wwn-id vsan vsan-id
Syntax Description
wwn-id
|
Specifies the port WWN, with the format hh:hh:hh:hh:hh:hh:hh:hh.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
One name server can be configured to proxy another name server and name server information can be displayed using the CLI. The name server can be viewed using the CLI or the Cisco Fabric Manager.
All name server registration requests come from the same port whose parameter is registered or changed. If it does not, then the request is rejected.
Examples
The following example shows configuring a proxy port for VSAN 2:
switch(config)# fcns proxy-port 21:00:00:e0:8b:00:26:d vsan 2
Related Commands
Command
|
Description
|
show fcns
|
Displays the name server database and statistical information for a specified VSAN or for all VSANs.
|
fcns reject-duplicate-pwwn vsan
To reject duplicate Fibre Channel name server (FCNS) proxies on a VSAN, use the fcns reject-duplicate-pwwn vsan command.
fcns reject-duplicate-pwwn vsan vsan-id
no fcns reject-duplicate-pwwn vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example rejects duplicate FCNS pWWNs for VSAN 2:
switch(config)# fcns reject-duplicate-pwwn vsan 2
Related Commands
Command
|
Description
|
show fcns
|
Displays the name server database and statistical information for a specified VSAN or for all VSANs.
|
fcping
To ping an N port, use the fcping command.
fcping {device-alias aliasname | fcid {fc-port | domain-controller-id} | pwwn pwwn-id} vsan
vsan-id [count number [timeout value [usr-priority priority]]]
Syntax Description
device-alias aliasname
|
Specifies the device alias name. Maximum length is 64 characters.
|
fcid
|
The FCID of the destination N port.
|
fc-port
|
The port FCID, with the format 0xhhhhhh.
|
domain-controller-id
|
Verifies connection to the destination switch.
|
pwwn pwwn-id
|
Specifies the port WWN of the destination N port, with the format hh:hh:hh:hh:hh:hh:hh:hh.
|
vsan vsan-id
|
Specifies the VSAN ID of the destination N port. The range is 1 to 4093.
|
count number
|
(Optional) Specifies the number of frames to send. A value of 0 sends forever. The range is 0 to 2147483647.
|
timeout value
|
(Optional) Specifies the timeout value in seconds. The range is 1 to 10.
|
usr-priority priority
|
(Optional) Specifies the priority the frame receives in the switch fabric. The range is 0 to 1.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
To obtain the domain controller ID, concatenate the domain ID with FFFC. For example, if the domain ID is 0xda(218), the concatenated ID is 0xfffcda.
Examples
The following example shows a fcping operation for the FCID of the destination. By default, five frames are sent.
switch# fcping fcid 0xd70000 vsan 1
The following example shows the setting of the number of frames to be sent using the count option. The range is from 0 through 2147483647. A value of 0 will ping forever.
switch# fcping fcid 0xd70000 vsan 1 count 10
The following example shows the setting of the timeout value. The default period to wait is 5 seconds. The range is from 1 through 10 seconds.
switch# fcping fcid 0xd500b4 vsan 1 timeout 10
The following example displays fcping operation using the device alias of the specified destination:
switch# fcping device-alias x vsan 1
fcroute
To configure Fibre Channel routes and to activate policy routing, use the fcroute command. To remove a configuration or revert to factory defaults, use the no form of the command.
fcroute {fcid [network-mask] interface {fc slot/port | san-port-channel port | vfc vfc-id} domain
domain-id {metric number | remote | vsan vsan-id}}
no fcroute {fcid network-mask interface {fc slot/port | san-port-channel port | vfc vfc-id} domain
domain-id {metric number | remote | vsan vsan-id}}
Syntax Description
fcid
|
Specifies the FC ID. The format is 0xhhhhhh.
|
network-mask
|
Specifies the network mask of the FC ID. The format is 0x0 to 0xffffff.
|
interface
|
Specifies an interface.
|
fc slot/port
|
Specifies a Fibre Channel interface.
|
san-port-channel port
|
Specifies a SAN port channel interface.
|
vfc vfc-id
|
Specifies a virtual Fibre Channel interface.
|
domain domain-id
|
Specifies the route for the domain of the next hop switch. The range is 1 to 239.
|
metric number
|
Specifies the cost of the route. The range is 1 to 65535. Default cost is 10.
|
remote
|
Configures the static route for a destination switch remotely connected.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Use this command to assign forwarding information to the switch and to activate a preferred path route map.
Examples
The following example specifies the Fibre Channel interface and the route for the domain of the next hop switch for VSAN 2:
switch(config)# fcroute 0x111211 interface fc3/1 domain 3 vsan 2
The following example specifies the SAN port channel interface and the route for the domain of the next hop switch for VSAN 4:
switch(config)# fcroute 0x111211 interface san-port-channel 1 domain 3 vsan 4
The following example specifies the Fibre Channel interface, the route for the domain of the next hop switch, and the cost of the route for VSAN 1:
switch(config)# fcroute 0x031211 interface fc1/1 domain 3 metric 1 vsan 1
The following example specifies the Fibre Channel interface, the route for the domain of the next hop switch, the cost of the route, and configures the static route for a destination switch remotely connected for VSAN 3:
switch(config)# fcroute 0x111112 interface fc3/1 domain 3 metric 3 remote vsan 3
Related Commands
Command
|
Description
|
show fcroute
|
Displays Fibre Channel routes.
|
fcroute-map
|
Specifies a preferred path Fibre Channel route map.
|
show fcroute-map
|
Displays the preferred path route map configuration and status.
|
fcroute policy fcroute-map
|
Activates the preferred path Fibre Channel route map.
|
fcs plat-check-global
To enable FCS platform and node-name checking fabric wide, use the fcs plat-check-global command. To disable this feature, use the no form of the command.
fcs plat-check-global vsan vsan-id
no fcs plat-check-global vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID for platform checking, which is from 1 to 4096.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to enable FCS platform and node-name checking fabric wide:
switch(config)# fcs plat-check-global vsan 2
Related Commands
Command
|
Description
|
show fcs
|
Displays fabric configuration server information.
|
fcs register
To register FCS attributes, use the fcs register command. To disable this feature, use the no form of the command.
fcs register
no fcs register
Syntax Description
This command has no arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to register FCS attributes:
switch(config)# fcs register
Related Commands
Command
|
Description
|
show fcs
|
Displays fabric configuration server information.
|
fcs virtual-device-add
To include a virtual device in a query about zone information from an FCS, use the fcs virtual-device-add command. To remove a virtual device, use the no form of the command.
fcs virtual-device-add [vsan-ranges vsan-ids]
no fcs virtual-device-add [vsan-ranges vsan-ids]
Syntax Description
vsan-ranges vsan-ids
|
(Optional) Specifies one or multiple ranges of VSANs. The range is 1 to 4093.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
VSAN ranges are entered as vsan-ids-vsan-ids. When you specify more than one range, separate each range with a comma. If no range is specified, the command applies to all VSANs.
Examples
The following example shows how to add to one range of VSANs:
switch(config)# fcs virtual-device-add vsan-ranges 2-4
The following example shows how to add to more than one range of VSANs:
switch(config)# fcs virtual-device-add vsan-ranges 2-4,5-8
Related Commands
Command
|
Description
|
show fcs
|
Displays fabric configuration server information.
|
fcsp
To configure an Fibre Channel Security Protocol (FC-SP) authentication mode for a specific interface in a FC-SP-enabled switch, use the fcsp command. To disable an FC-SP on the interface, use the no form of the command.
fcsp {auto-active | auto-passive | on | off} [timeout-period]
no fcsp
Syntax Description
auto-active
|
Configures the auto-active mode to authenticate the specified interface.
|
auto-passive
|
Configures the auto-passive mode to authenticate the specified interface.
|
on
|
Configures the on mode to authenticate the specified interface.
|
off
|
Configures the off mode to authenticate the specified interface.
|
timeout-period
|
(Optional) Specifies the time out period to reauthenticate the interface. The time ranges from 0 (default—no authentication is performed) to 100,000 minutes.
|
Command Default
Auto-passive mode
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
To use this command, FC-SP must be enabled using the fcsp enable command.
Examples
The following example turns on the authentication mode for Fibre Channel interface in port 1 of slot 2:
switch(config)# interface fc 2/1
switch(config-if)# fcsp on
The following example reverts to the factory default of auto-passive for the selected interface:
switch(config-if)# no fcsp
The following example changes the selected interface to initiate FC-SP authentication, but does not permit reaunthentication:
switch(config-if)# fcsp auto-active 0
Related Commands
Command
|
Description
|
fcsp enable
|
Enables FC-SP.
|
show interface
|
Displays an interface configuration for a specified interface.
|
fcsp dhchap
To configure DHCHAP options in a switch, use the fcsp dhchap command. This command is only available when the FC-SP feature is enabled. Use the no form of the command to revert to factory defaults.
fcsp dhchap {devicename switch-wwn password [0 | 7] password |
dhgroup [0] [1][2][3 ][4] | hash [md5 | sha1] | password [0 | 7] password [wwn wwn-id]}
no fcsp dhchap {devicename switch-wwn password [0 | 7] password |
dhgroup [0 | 1| 2 | 3 | 4] | hash [md5] [sha1] | password [0 | 7] password [wwn-id]}
Syntax Description
devicename
|
Configures a password of another device in the fabric.
|
switch-wwn
|
Provides the WWN of the device being configured.
|
password
|
Configures DHCHAP password for the local switch.
|
0
|
(Optional) Specifies a clear text password.
|
7
|
(Optional) Specifies a password in encrypted text.
|
dhgroup
|
Configures DHCHAP Diffie-Hellman group priority list.
|
0
|
(Optional) Null DH—no exchange is performed (default).
|
1 | 2 | 3 | 4
|
(Optional) Specifies one or more of the groups specified by the standards.
|
hash
|
Configures DHCHAP hash algorithm priority list in order of preference.
|
md5
|
(Optional) Specifies the MD5 hash algorithm.
|
sha1
|
(Optional) Specifies the SHA-1 hash algorithm.
|
wwn wwn-id
|
(Optional) The WWN ID with the format hh:hh:hh:hh:hh:hh:hh:hh.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
You can only see the fcsp dhchap command if you enter the fcsp enable command.
Using SHA-1 as the hash algorithm may prevent RADIUS or TACACS+ usage.
If you change the DH group configuration, ensure to change it globally for all switches in the fabric.
Examples
The following example enables FC-SP:
switch(config)# # fcsp enable
The following example configures the use of only the SHA-1 hash algorithm:
switch(config)# fcsp dhchap hash sha1
The following example configures the use of only the MD-5 hash algorithm:
switch(config)# fcsp dhchap hash md5
The following example defines the use of the default hash algorithm priority list of MD-5 followed by SHA-1 for DHCHAP authentication:
switch(config)# fcsp dhchap hash md5 sha1
The following example reverts to the factory default priority list of the MD-5 hash algorithm followed by the SHA-1 hash algorithm:
switch(config)# no fcsp dhchap hash sha1
The following example prioritizes the use of DH group 2, 3, and 4 in the configured order:
switch(config)# fcsp dhchap group 2 3 4
The following example configures a clear text password for the local switch:
switch(config)# fcsp dhchap password 0 mypassword
The following example configures a clear text password for the local switch to be used for the device with the specified WWN:
switch(config)# fcsp dhchap password 0 mypassword 30:11:bb:cc:dd:33:11:22
The following example configures a password entered in an encrypted format for the local switch:
switch(config)# fcsp dhchap password 7 sfsfdf
Related Commands
Command
|
Description
|
fcsp enable
|
Enable FC-SP.
|
show fcsp
|
Displays configured FC-SP information.
|
fcsp enable
To enable the Fibre Channel Security Protocol (FC-SP) in a switch, use the fcsp enable command. Additional FC-SP commands are available when the FC-SP feature is enabled. To disable FC-SP, use the no form of the command.
fcsp enable
no fcsp enable
Syntax Descriptionf
fcsp
|
Specifies the FC-SP feature in the switch.
|
enable
|
Enables the FC-SP feature in this switch.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example enables FC-SP:
switch(config)# fcsp enable
Related Commands
Command
|
Description
|
show fcsp
|
Displays configured FC-SP information.
|
fcsp reauthenticate
To reauthenticate a Fibre Channel or virtual Fibre Channel interface, use the fcsp reauthenticate command. Use the no form of the command to revert to factory defaults.
fcsp reauthenticate interface { fc slot/port | vfc vfc-id }
no fcsp reauthenticate interface { fc slot/port | vfc vfc-id }
Syntax Description
interface
|
Specifies the interface on which to perform the reauthentication.
|
interface fc slot/port
|
Specifies the Fibre Channel interface by slot and port number.
|
vfc vfc-id
|
Specifies the virtual Fibre Channel interface by virtual interface group number and virtual interface ID.
|
Command Default
30 seconds
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example configures the FCSP reauthentication on a virtual Fibre Channel interface:
switch# fcsp reauthenticate vfc 1
Related Commands
Command
|
Description
|
fcsp enable
|
Enable FC-SP.
|
show fcsp
|
Displays configured FC-SP information.
|
fcsp timeout
To configure the timeout value for FC-SP message, use the fcsp timeout command. Use the no form of the command to revert to factory defaults.
fcsp timeout timeout-period
no fcsp timeout timeout-period
Syntax Description
timeout-period
|
Specifies the time out period. The time ranges from 20 to 100 seconds.
|
Command Default
30 seconds.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
You can only see the fcsp timeout command if you enter the fcsp enable command.
Examples
The following example configures the FCSP timeout value:
switch(config)# fcsp enable
switch(config)# fcsp timeout 60
Related Commands
Command
|
Description
|
fcsp enable
|
Enable FC-SP.
|
show fcsp
|
Displays configured FC-SP information.
|
fctimer
To change the default Fibre Channel timers, use the fctimer command. To revert to the default values, use the no form of the command.
fctimer {d_s_tov milliseconds | e_d_tov milliseconds | r_a_tov milliseconds} [vsan vsan-id]
no fctimer {d_s_tov milliseconds | e_d_tov milliseconds | r_a_tov milliseconds} [vsan vsan-id]
Syntax Description
d_s_tov milliseconds
|
Specifies the distributed services timeout value (DS_TOV). The range is 5000 to 100000 milliseconds.
|
e_d_tov milliseconds
|
Specifies the error detect timeout value (ED_TOV). The range is 1000 to 100000 milliseconds, with a default of 2000.
|
r_a_tov milliseconds
|
Specifies the resolution allocation timeout value (RA_TOV). The range is 5000 to 100000 milliseconds with a default of 10000.
|
vsan vsan-id
|
(Optional) Specifies the VSAN ID. The range is 1 to 4096.
|
Command Default
The Fibre Channel timers have the following default values:
•
30 seconds for DS_TOV.
•
2 seconds for ED_TOV.
•
10 seconds for RA_TOV.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The Cisco, Brocade, and McData FC Error Detect (ED_TOV) and Resource Allocation (RA_TOV) timers default to the same values. They can be changed if needed. In accordance with the FC-SW2 standard, these values must be the same on each switch in the fabric.
Use the vsan option to configure different TOV values for specific VSANs.
Examples
The following example shows how to change the default Fibre Channel timers:
switch(config)# fctimer e_d_tov 5000
switch(config)# fctimer r_a_tov 7000
Related Commands
Command
|
Description
|
show fctimer
|
Displays the configured Fibre Channel timer values.
|
fctimer abort
To discard a Fibre Channel timer (fctimer) Cisco Fabric Services (CFS) distribution session in progress, use the fctimer abort command.
fctimer abort
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to discard a CFS distribution session in progress:
switch(config)# fctimer abort
Related Commands
Command
|
Description
|
fctimer distribute
|
Enables CFS distribution for fctimer.
|
show fctimer
|
Displays fctimer information.
|
fctimer commit
To apply the pending configuration pertaining to the Fibre Channel timer (fctimer) Cisco Fabric Services (CFS) distribution session in progress in the fabric, use the fctimer commit command.
fctimer commit
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Examples
The following example shows how to commit changes to the active Fibre Channel timer configuration:
switch(config)# fctimer commit
Related Commands
Command
|
Description
|
fctimer distribute
|
Enables CFS distribution for fctimer.
|
show fctimer
|
Displays fctimer information.
|
fctimer distribute
To enable Cisco Fabric Services (CFS) distribution for Fibre Channel timer (fctimer), use the fctimer distribute command. To disable this feature, use the no form of the command.
fctimer distribute
no fctimer distribute
Syntax Description
This command has no other arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Before distributing the Fibre Channel timer changes to the fabric, the temporary changes to the configuration must be committed to the active configuration using the fctimer commit command.
Examples
The following example shows how to change the default Fibre Channel timers:
switch(config)# fctimer distribute
Related Commands
Command
|
Description
|
fctimer commit
|
Commits the Fibre Channel timer configuration changes to the active configuration.
|
show fctimer
|
Displays fctimer information.
|
fctrace
To trace the route to an N port, use the fctrace command.
fctrace {device-alias aliasname | fcid fcid | pwwn pwwn-id} vsan vsan-id [timeout seconds]
Syntax Description
device-alias aliasname
|
Specifies the device alias name. Maximum length is 64 characters.
|
fcid fcid
|
The FCID of the destination N port, with the format 0xhhhhhh
|
pwwn pwwn-id
|
The PWWN of the destination N port, with the format hh:hh:hh:hh:hh:hh:hh:hh.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
timeout seconds
|
Configures the timeout value. The range is 1 to 10.
|
Command Default
By default, the period to wait before timing out is 5 seconds.
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example traces a route to the specified fcid in VSAN 1:
switch# fctrace fcid 0x660000 vsan 1
The following example traces a route to the specified device alias in VSAN 1:
switch# fctrace device-alias x vsan 1
fdmi suppress-updates
To suppress FDMI updates, use the fdmi suppress-updates command.
fdmi suppress-updates vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
By default, FDMI updates are not suppressed.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example suppresses FDMI updates in VSAN 1:
switch# fdmi suppress-updates vsan 1
feature npiv
To enable N Port Identifier Virtualization (NPIV) for all Virtual SANs (VSANs) on a switch, use the feature npiv command. To disable NPIV, use the no form of this command.
feature npiv
no feature npiv
Syntax Description
This command has no arguments or keywords.
Command Default
Disabled
Command Modes
Global configuration mode
Command History
Release
|
Modification
|
4.1(3)N1(1)
|
This command was introduced.
Note On a Cisco Nexus 5000 Series switch that runs a Cisco NX-OS release prior to 4.1(3)N1(1), this command was known as the npiv enable command.
|
Usage Guidelines
NPIV provides a means to assign multiple port IDs to a single N port. This feature allows multiple applications on the N port to use different identifiers and allows access control, zoning, and port security to be implemented at the application level.
You must globally enable NPIV for all VSANs on the switch to allow the NPIV-enabled applications to use multiple N port identifiers.
Examples
This example shows how to enable NPIV for all VSANs on the switch:
switch(config)# feature npiv
This example shows how to disable NPIV for all VSANs on the switch:
switch(config)# no feature npiv
Related Commands
Command
|
Description
|
show interface
|
Displays interface configurations.
|
fspf config
To configure an FSPF feature for an entire VSAN, use the fspf config command. This command enters FSPF configuration mode, which includes four commands (each with a no form).
To delete FSPF configuration for the entire VSAN, use the no form of the command.
fspf config vsan vsan-id
min-ls-arrival ls-arrival-time
min-ls-interval ls-interval-time
region region-id
spf {hold-time spf-holdtime | static}
no min-ls-arrival
no min-ls-interval
no region
no spf {hold-time | static}
no fspf config vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
min-ls-arrival ls-arrival-time
|
This command specifies the minimum time before a new link state update for a domain will be accepted by switch. The parameter ls-arrival-time is an integer specifying time in milliseconds. The range is 0 to 65535.
|
min-ls-interval ls-interval-time
|
This command specifies the minimum time before a new link state update for a domain will be generated by the switch. The parameter ls-interval-time is an integer specifying time in milliseconds. The range is 0 to 65535.
|
region region-id
|
This command specifies the autonomous region to which the switch belongs. The backbone region has region-id=0. The parameter region-id is an unsigned integer value ranging from 0 to 255.
|
spf
|
This command specifies parameters related to SPF route computation.
|
hold-time spf-holdtime
|
Specifies the time between two consecutive SPF computations. If the time is small then routing will react faster to changes but CPU usage will be more. The parameter spf-holdtime is an integer specifying time in milliseconds. The range is 0 to 65535.
|
static
|
Forces static SPF computation.
|
Command Default
In FSPF configuration mode, the default is dynamic SPF computation.
If configuring spf hold-time, the default value for FSPF is 0.
If configuring min-ls-arrival, the default value for FSPF is 1000 milliseconds.
If configuring min-ls-interval, the default value for FSPF is 5000 milliseconds.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The fspf config command enters FSPF configuration mode for the specified VSAN. In FSPF configuration mode, the commands configure FSPF for this VSAN .
Examples
The following example configures static SPF computation in VSAN 1 and deletes the FSPF configuration in VSAN 3:
switch(config)# fspf config vsan 1
switch(fspf-config)# spf static
switch(fspf-config)# exit
switch(config)# no fspf config vsan 3
switch(config)#
Related Commands
Command
|
Description
|
show fspf interface
|
Displays information for each selected interface.
|
fspf enable
|
Enables FSPF routing protocol in the specified VSAN
|
fspf cost
|
Configures the cost for the selected interface in the specified VSAN
|
fspf hello-interval
|
Specifies the hello message interval to verify the health of a link in the VSAN
|
fspf passive
|
Disables the FSPF protocol for the specified interface in the specified VSAN
|
fspf retransmit
|
Specifies the retransmit time interval for unacknowledged link state updates in specified VSAN
|
fspf cost
To configure FSPF link cost for an FCIP interface, use the fspf cost command. To revert to the default value, use the no form of the command.
fspf cost link-cost vsan vsan-id
no fspf cost link-cost vsan vsan-id
Syntax Description
link-cost
|
Enters FSPF link cost in seconds. The range is 1 to 65535.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
1000 seconds for 1 Gigabits per second interfaces.
500 seconds for 2 Gigabits per second interfaces.
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command is not applicable to virtual Fibre Channel interfaces.
FSPF tracks the state of links on all switches in the fabric, associates a cost with each link in its database, and then chooses the path with a minimal cost. The cost associated with an interface can be changed using the fspf cost command to implement the FSPF route selection.
Examples
The following example configures the FSPF link cost on an FCIP interface:
switch(config)# interface fc 2/1
switch(config-if)# fspf cost 5000 vsan 1
Related Commands
Command
|
Description
|
show fspf interface
|
Displays information for each selected interface.
|
show interface fc
|
Displays an interface configuration for a specified Fibre Channel interface.
|
fspf dead-interval
To set the maximum interval for which a hello message must be received before the neighbor is considered lost, use the fspf dead-interval command. To revert to the default value, use the no form of the command.
fspf dead-interval seconds vsan vsan-id
no fspf dead-interval seconds vsan vsan-id
Syntax Description
seconds
|
Specifies the FSPF dead interval in seconds. The range is 2 to 65535.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
80 seconds.
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command is not applicable to virtual Fibre Channel interfaces. This value must be the same in the ports at both ends of the ISL.
Caution 
An error is reported at the command prompt if the configured dead time interval is less than the hello time interval.
Examples
The following example configures the maximum interval of 400 seconds for a hello message before the neighbor is considered lost:
switch(config)# interface fc 2/1
switch(config-if)# fspf dead-interval 4000 vsan 1
Related Commands
Command
|
Description
|
show fspf interface
|
Displays information for each selected interface.
|
show interface fc
|
Displays an interface configuration for a specified Fibre Channel interface.
|
fspf enable
To enable FSPF for a VSAN, use the fspf enable command. To disable FSPF routing protocols, use the no form of the command.
fspf enable vsan vsan-id
no fspf enable vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
Enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command configures FSPF on VSANs globally.
Examples
The following example enables FSPF in VSAN 5 and disables FSPF in VSAN 7:
switch(config)# fspf enable vsan 5
switch(config)# no fspf enable vsan 7
Related Commands
Command
|
Description
|
fspf config vsan
|
Configures FSPF features for a VSAN.
|
show fspf interface
|
Displays information for each selected interface.
|
fspf hello-interval
To verify the health of the link, use the fspf hello-interval command. To revert to the default value, use the no form of the command.
fspf hello-interval seconds vsan vsan-id
no fspf hello-interval seconds vsan vsan-id
Syntax Description
hello-interval seconds
|
Specifies the FSPF hello-interval in seconds. The range is 2 to 65535.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
20 seconds.
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command is not applicable to virtual Fibre Channel interfaces.
This command configures FSPF for the specified Fibre Channel interface. This value must be the same in the ports at both ends of the ISL.
Examples
The following example configures a hello interval of 3 seconds on VSAN 1:
switch(config)# interface fc 2/1
switch(config-if)# fspf hello-interval 3 vsan 1
Related Commands
Command
|
Description
|
show fspf interface
|
Displays information for each selected interface.
|
fspf passive
To disable the FSPF protocol for selected interfaces, use the fspf passive command. To revert to the default state, use the no form of the command.
fspf passive vsan vsan-id
no fspf passive vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
FSPF is enabled.
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command is not applicable to virtual Fibre Channel interfaces.
By default, FSPF is enabled on all E ports and TE ports. FSPF can be disabled by setting the interface as passive using the fspf passive command. FSPF must be enabled on the ports at both ends of the ISL for the protocol to operate correctly.
Examples
The following example disables the FSPF protocol for the selected interface on VSAN 1:
switch(config)# interface fc 2/1
switch(config-if)# fspf passive vsan 1
Related Commands
Command
|
Description
|
show fspf interface
|
Displays information for each selected interface.
|
show interface fc
|
Displays an interface configuration for a specified FCIP interface.
|
fspf retransmit-interval
To specify the time after which an unacknowledged link state update should be transmitted on the interface, use the fspf retransmit-interval command. To revert to the default value, use the no form of the command.
fspf retransmit-interval seconds vsan vsan-id
no spf retransmit-interval seconds vsan vsan-id
Syntax Description
seconds
|
Specifies FSPF retransmit interval in seconds. The range is 1 to 65535.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
5 seconds.
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command is not applicable to virtual Fibre Channel interfaces. This value must be the same in the ports at both ends of the ISL.
Examples
The following example specifies a retransmit interval of 6 seconds after which an unacknowledged link state update should be transmitted on the interface for VSAN 1:
switch(config)# interface fc 2/1
switch(config-if)# fspf retransmit-interval 6 vsan 1
Related Commands
Command
|
Description
|
show fspf interface
|
Displays information for each selected interface.
|
show interface fc
|
Displays an interface configuration for a specified FCIP interface.
|
in-order-guarantee
To enable in-order delivery, use the in-order-guarantee command. To disable in-order delivery, use the no form of the command.
in-order-guarantee [vsan vsan-id]
no in-order-guarantee [vsan vsan-id] [,] [-]
Syntax Description
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
[,] [-]
|
(Optional) Allows you to enter multiple VSANs separated by commas, or a range of VSANs separated by a dash.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
In-order delivery of data frames guarantees frame delivery to a destination in the same order that they were sent by the originator.
Examples
The following example shows how to enable in-order delivery for the entire switch:
switch(config) # in-order-guarantee
The following example shows how to disable in-order delivery for the entire switch:
switch(config)# no in-order-guarantee
The following example shows how to enable in-order delivery for a specific VSAN:
switch(config)# in-order-guarantee vsan 3452
The following example shows how to disable in-order delivery for a specific VSAN:
switch(config)# no in-order-guarantee vsan 101
Related Commands
Command
|
Description
|
show in-order-guarantee
|
Displays the in-order-guarantee status.
|
interface fc
To configure a Fibre Channel interface on a Cisco Nexus 5000 Series switch, use the interface fc command. The interface fc command enters interface configuration mode, which includes five commands (each with a no form).
To revert to defaults, use the no form of the command.
interface fc slot/port
channel-group {group-id [force] | auto}
fcdomain rcf-reject vsan vsan-id
fcsp {auto-active | auto-passive | on | off} [timeout-period]
fspf {cost link-cost vsan vsan-id | dead-interval seconds vsan vsan-id | hello-interval seconds
vsan vsan-id | passive vsan vsan-id | retransmit-interval seconds vsan vsan-id}
switchport
no interface fc slot/port
no channel-group {group-id [force] | auto}
no fcdomain rcf-reject vsan vsan-id
no fcsp {auto-active | auto-passive | on | off}
no fspf {cost link-cost vsan vsan-id | dead-interval seconds vsan vsan-id | hello-interval
seconds vsan vsan-id | passive vsan vsan-id | retransmit-interval seconds vsan vsan-id}
switchport
Syntax Description
slot/port
|
Specifies a slot number and port number.
|
channel-group
|
Adds to or removes from a Port Channel.
|
group-id
|
Specifies a Port Channel group number from 1 to 128.
|
force
|
Forcefully adds a port.
|
auto
|
Enables autocreation of port channels.
|
fcdomain
|
Enters the interface mode.
|
rcf-reject
|
Configures the rcf-reject flag.
|
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
fspf
|
Configures FSPF parameters.
|
cost link-cost
|
Configures FSPF link cost. The range is 1 to 65535.
|
dead-interval seconds
|
Configures FSPF dead interval in seconds. The range is 2 to 65535.
|
hello-interval seconds
|
Configures FSPF hello-interval. The range is 1 to 65535.
|
passive
|
Enables or disables FSPF on the interface.
|
retransmit-interval seconds
|
Configures FSPF retransmit interface in seconds. The range is 1 to 65535.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
You can specify a range of interfaces by entering a command with the following example format:
interface fc 1/1 - 5 , fc 2/5 - 7
Refer to the Cisco Nexus 5000 Series CLI Configuration Guide for information on port number allocation.
Use the no shutdown command to enable the interface.
The channel-group auto command enables autocreation of port channels. If autocreation of port channels is enabled for an interface, you must first disable this configuration before downgrading to earlier software versions or before configuring the interface in a manually configured channel group.
Examples
The following example configures ports 1 to 4 in Fibre Channel interface 3:
switch(config)# interface fc 3/1 - 4
The following example enables the Fibre Channel interface in port 1 of slot 3:
switch(config)# interface fc 3/1
switch(config-if)# no shutdown
Related Commands
Command
|
Description
|
show interface
|
Displays an interface configuration for a specified interface.
|
shutdown
|
Disables and enables an interface.
|
interface san-port-channel
To configure a SAN port channel interface on a Cisco Nexus 5000 Series switch, use the interface san-port-channel command. The interface san-port-channel command enters interface configuration mode, which includes six commands (each with a no form).
To revert to defaults, use the no form of the command.
interface san-port-channel port
description line
shutdown [force]
switchport {
mode { E | auto} |
speed { 1000 | 2000 | 4000 | auto} |
trunk { allowed vsan {vsan-id | add vsan-id | all} | mode {auto | on | off}}
}
no interface san-port-channel port
no description
no shutdown
no switchport {
no mode |
no speed |
no trunk { allowed vsan { vsan-id | add vsan-id | all}| mode }
Syntax Description
port
|
Specifies a port number.
|
description line
|
Enters a line of text to describe the interface.
|
shutdown
|
Changes the interface state to administrative down.
|
force
|
Forces the interface state to administrative down.
|
switchport
|
Enters configuration parameters for the SAN port channel .
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Use the no shutdown command to enable the interface.
Examples
The following example configures SAN port channel interface 3:
switch(config)# interface san-port-channel 3
Related Commands
Command
|
Description
|
show interface
|
Displays an interface configuration for a specified interface.
|
shutdown
|
Disables and enables an interface.
|
interface vfc
To configure a virtual Fibre Channel interface on a Cisco Nexus 5000 Series switch, use the interface vfc command. To revert to defaults, use the no form of the command.
interface vfc vfc-id
bind interface ethernet slot/port
description line
shutdown [force]
switchport mode F
no interface vfc vfc-id
no bind interface ethernet slot/port
no description
no shutdown
no switchport mode
Syntax Description
vfc-id
|
Specifies a virtual interface ID.
|
bind interface ethernet slot/port
|
Binds the virtual Fibre Channel interface to the specified Ethernet interface.
|
description line
|
Enters a line of text to describe the interface.
|
shutdown
|
Changes the interface state to administrative down.
|
switchport mode F
|
Specifies the mode of the virtual Fibre Channel interface.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
You can specify a range of interfaces by entering a command with the following example format:
interface vfc 1 - 3 , vfc 5 - 7
Use the no shutdown command to enable the interface.
Examples
The following example enters interface configuration mode for virtual Fibre Channel interface 3:
switch(config)# interface vfc 3
Related Commands
Command
|
Description
|
show interface
|
Displays an interface configuration for a specified interface.
|
shutdown
|
Disables and enables an interface.
|
lldp
To configure the Link Layer Discovery Protocol (LLDP) global options, use the lldp command. To remove the LLDP settings, use the no form of this command.
lldp {holdtime seconds | reinit seconds | timer seconds}
no lldp {holdtime | reinit | timer}
Syntax Description
holdtime seconds
|
Specifies the hold time (in seconds) to set the length of time that a device should save LLDP information received before discarding it.
The range is from 10 to 255, and the default is 120 seconds.
|
reinit seconds
|
Specifies the length of time (in seconds) to wait before performing LLDP initialization on any interface.
The range is from 1 to 10 seconds, and the default is 2 seconds.
|
timer seconds
|
Specifies the rate (in seconds) at which LLDP packets are sent.
The range is from 5 to 254 seconds, and the default is 30 seconds.
|
Command Default
Holdtime: 120 seconds.
Reinit: 2 seconds.
Timer: 30 seconds.
Command Modes
Global configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The LLDP settings include the length of time before discarding LLDP information received from peers, the length of time to wait before performing LLDP initialization on any interface, and the rate at which LLDP packets are sent.
Examples
This example shows how to configure the global LLDP holdtime to 200 seconds:
switch(config)# lldp holdtime 200
Related Commands
Command
|
Description
|
lldp (Interface)
|
Configures the LLDP feature on an interface.
|
show lldp
|
Displays the LLDP configuration information.
|
lldp (interface)
To enable the reception, or transmission, of Link Layer Discovery Protocol (LLDP) packets on an interface, use the lldp command. To disable the reception or transmission of LLDP packets, use the no form of this command.
lldp {receive | transmit}
no lldp {receive | transmit}
Syntax Description
receive
|
Specifies that the interface receive LLDP packets.
|
transmit
|
Specifies that the interface transmit LLDP packets.
|
Command Default
None
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
This example shows how to set an interface to transmit LLDP packets:
switch(config)# interface ethernet 2/1
switch(config-if)# lldp transmit
Related Commands
Command
|
Description
|
show interface
|
Displays configuration information about interfaces.
|
logging abort
To discard the logging Cisco Fabric Services (CFS) distribution session in progress, use the logging abort command.
logging abort
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to discard logging CFS distribution session in progress:
switch(config)# logging abort
Related Commands
Command
|
Description
|
show logging
|
Displays logging information.
|
logging commit
To apply the pending configuration pertaining to the logging Cisco Fabric Services (CFS) distribution session in progress in the fabric, use the logging commit command.
logging commit
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to commit changes to the active logging configuration:
switch(config)# logging commit
Related Commands
Command
|
Description
|
show logging
|
Displays logging information.
|
logging distribute
To enable Cisco Fabric Services (CFS) distribution for logging, use the logging distribute command. To disable this feature, use the no form of the command.
logging distribute
no logging distribute
Syntax Description
This command has no other arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Before distributing the Fibre Channel timer changes to the fabric, the temporary changes to the configuration must be committed to the active configuration using the logging commit command.
Examples
The following example shows how to change the distribute logging configuration changes:
switch(config)# logging distribute
Related Commands
Command
|
Description
|
logging commit
|
Commits the logging configuration changes to the active configuration.
|
show logging
|
Displays logging information.
|
member (fcalias configuration mode)
To add a member name to a Fibre Channel alias on a VSAN, use the member command. To remove a member name from a Fibre Channel alias, use the no form of the command.
member {device-alias aliasname | domain-id domain-id port-number port-number | fcid fc-id |
fwwn fwwn-id | interface fc slot/port [domain-id domain-id | swwn swwn-id] | pwwn pwwn-id
| symbolic-nodename nodename}
no member {device-alias aliasname | domain-id domain-id port-number port-number | fcid fc-id
| fwwn fwwn-id | interface fc slot/port [domain-id domain-id | swwn swwn-id] | pwwn pwwn-id
| symbolic-nodename nodename}
Syntax Description
device-alias aliasname
|
Specifies the member device alias. Maximum length is 64 characters.
|
domain-id domain-id
|
Specifies the member domain ID. The range is 1 to 239.
|
fcid fc-id
|
Specifies the member FC ID. The format is 0xhhhhhh, where h is a hexadecimal digit.
|
fwwn fwwn-id
|
Specifies the member fWWN ID. The format is hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal digit.
|
interface fc slot/port
|
Specifies the member interface ID.
|
swwn swwn-id
|
(Optional) Specifies the member sWWN ID. The format is hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal digit.
|
port-number port-number
|
Specifies a port number in the range of 0 to 255.
|
pwwn pwwn-id
|
Specifies the member pWWN ID. The format is hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal digit.
|
symbolic-nodename nodename
|
Specifies the member symbolic node name. The maximum length is 255 characters.
|
Command Default
None
Command Modes
Fcalias configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to add a member to an alias called samplealias:
switch(config)# fcalias name samplealias
The following example defines a Fibre Channel interface for the member:
switch(switch(config-fcalias)# member interface fc3/1
The following example shows how to delete the specified member:
switch(config-fcalias)# no member interface fc3/1
Related Commands
Command
|
Description
|
fcalias name
|
Configures an alias.
|
show fcalias
|
Displays the member name information in an alias.
|
member (zone configuration mode)
To add a member name to a Fibre Channel zone, use the member command. To remove a member name from a zone, use the no form of the command.
member {device-alias aliasname | domain-id domain-id port-number port | fcalias alias-name |
fcid fc-id | fwwn fwwn-id | interface fc slot/port [domain-id domain-id | swwn swwn-id] |
pwwn pwwn-id [lun lun-id] | symbolic-nodename nodename}
no member {device-alias aliasname | domain-id domain-id port-number port | fcid fc-id | fwwn
fwwn-id | interface fc slot/port [domain-id domain-id | swwn swwn-id] | pwwn pwwn-id [lun
lun-id] | symbolic-nodename nodename}
Syntax Description
device-alias aliasname
|
Specifies the member device alias. Maximum length is 64 characters.
|
lun lun-id
|
Specifies the member LUN ID. The format is 0xhhhh[:hhhh[:hhhh[:hhhh]]], where h is a hexadecimal digit.
|
domain-id domain-id
|
Specifies the member domain ID. The range is 1 to 239.
|
alias-name
|
The name of the fcalias. Maximum length is 64 characters.
|
port-number port
|
Specifies the member port number. The range is 0 to 255.
|
fcid fc-id
|
Specifies the member FC ID. The format is 0xhhhhhh, where h is a hexadecimal digit.
|
fwwn fwwn-id
|
Specifies the member fWWN ID. The format is hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal digit.
|
interface fc slot/port
|
Specifies the member interface ID.
|
swwn swwn-id
|
Specifies the member sWWN ID. The format is hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal digit.
|
pwwn pwwn-id
|
Specifies the member pWWN ID. The format is hh:hh:hh:hh:hh:hh:hh:hh, where h is a hexadecimal digit.
|
symbolic-nodename nodename
|
Specifies the member symbolic node name. The maximum length is 255 characters.
|
Command Default
None
Command Modes
Zone set zone configuration mode and zoneset-zone configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Create a zone set zone member only if you need to add member to a zone from the zone set prompt.
Examples
The following example shows how to add a member to a zone called zs1 on VSAN 1:
switch(config)# zone name zs1 vsan 1
switch(config-zone)# member fcid 0x111112
The following example shows how to add a zone to a zoneset called Zoneset1 on VSAN 1:
switch(config)# zoneset name ZoneSet1 vsan 1
switch(config-zoneset-zone)# member fcid 0x111112
The following example shows how to assign a Fibre Channel interface member into a zone:
switch(config)# zoneset name ZoneSet1 vsan 1
switch(config-zoneset-zone)# member interface fc 3/1
The following example shows how to delete the specified device from a zone:
switch(config-zoneset-zone)# no member interface fc 3/1
Related Commands
Command
|
Description
|
zoneset (configuration mode)
|
Used to specify a name for a zone set.
|
zone name (zone set configuration mode)
|
Configures a zone in a zoneset.
|
show zoneset
|
Displays zone set information.
|
member (zoneset configuration mode)
To configure zone set members, use the member command in zone set configuration mode. To remove a zone set member, use the no form of the command.
member member-name
no member member-name
Syntax Description
member-name
|
Specifies the member name. Maximum length is 64 characters.
|
Command Default
None
Command Modes
Zone set configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to add a member zone to a zone set:
switch(config)# zoneset name Zoneset1 vsan 10
switch(config-zoneset)# member ZoneA
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zoneset name
|
Creates a zone set.
|
npiv enable
To enable N Port Identifier Virtualization (NPIV) for all VSANs on a switch, use the npiv enable command. To disable NPIV, use the no form of the command.
npiv enable
no npiv enable
Syntax Description
This command has no arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
4.1(3)N1(1)
|
This command was deprecated and replaced with the feature npiv command. For backward compatibility, it will be maintained for a number of releases.
|
Usage Guidelines
NPIV provides a means to assign multiple port IDs to a single N port. This feature allows multiple applications on the N port to use different identifiers and allows access control, zoning, and port security to be implemented at the application level.
You must globally enable NPIV for all VSANs on the switch to allow the NPIV-enabled applications to use multiple N port identifiers.
Examples
The following example enables NPIV for all VSANs on the switch:
switch(config)# npiv enable
The following example disables NPIV for all VSANs on the switch:
switch(config)# no npiv enable
Related Commands
Command
|
Description
|
show interface
|
Displays interface configurations.
|
npv auto-load-balance disruptive
To enable N Port Virtualization (NPV) disruptive load-balancing, use the npv auto-load-balance disruptive command. To disable this feature, use the no form of the command.
npv auto-load-balance disruptive
no npv auto-load-balance disruptive
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(2a)
|
This command was introduced.
|
Usage Guidelines
Disruptive load-balancing can be configured only in NPV mode.
When disruptive load-balancing is enabled, NPV redistributes the server interfaces across all available NP uplinks when a new NP uplink becomes operational. To move a server interface from one NP uplink to another NP uplink, NPV forces reinitialization of the server interface so that the server performs a new login to the core switch. This action causes traffic disruption on the attached end devices.
To avoid disruption of server traffic, enable this feature only after adding a new NP uplink, and then disable it again after the server interfaces have been redistributed.
Examples
The following example shows how to enable disruptive load-balancing:
switch(config)# npv auto-load-balance disruptive
Related Commands
Command
|
Description
|
npv enable
|
Enables NPV mode.
|
show npv status
|
Displays the NPV current status.
|
npv enable
To enable N Port Virtualization (NPV) mode, use the npv enable command. To disable this feature, use the no form of the command.
npv enable
no npv enable
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
When NPV mode is enabled, switch configuration related to interfaces is erased and the switch is rebooted. The switch restarts in NPV mode. Configuration and verification commands for NPV are available only when NPV is enabled on the switch. When you disable NPV mode, all related configurations are automatically erased and the switch is rebooted.
Examples
The following example shows how to enable NPV mode:
switch(config)# npv enable
Related Commands
Command
|
Description
|
show npv status
|
Displays the NPV current status.
|
npv traffic-map
To configure a N Port Virtualization (NPV) traffic map, use the npv traffic map command. To disable this feature, use the no form of the command. This command is only available when the switch is operating in NPV mode.
npv traffic-map server-interface {fc slot/port | vfc vfc-id} external-interface fc slot/port
no npv traffic-map server-interface {fc slot/port | vfc vfc-id} external-interface fc slot/port
Syntax Description
server-interface
|
Specifies the server interface or a range of server interfaces.
|
fc slot/port
|
Specifies the slot number and port number for a native Fibre Channel interface.
|
vfc vfc-id
|
Specifies a virtual Fibre Channel interface.
|
external-interface
|
Specifies the NP uplink interface or a range of NP uplink interfaces that can be selected by the server interface.
|
Command Default
No traffic map. The switch uses automatic uplink selection to select an NP uplink for the server interface.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(2a)
|
This command was introduced.
|
Usage Guidelines
NPV traffic maps can be configured only in NPV mode.
Examples
The following example creates a mapping between server interface vfc1 and NP uplink fc 3/1:
switch(config)# npv traffic-map server-interface vfc 1 external-interface fc 3/1
Related Commands
Command
|
Description
|
npv enable
|
Enables NPV mode.
|
show npv status
|
Displays the NPV current status.
|
port-security
To configure port security features and reject intrusion attempts, use the port-security command. Use the no form of the command to negate the command or revert to factory defaults.
port-security {activate vsan vsan-id [force | no-auto-learn] | auto-learn vsan vsan-id | database
vsan vsan-id}
no port-security {activate vsan vsan-id [force | no-auto-learn] | auto-learn vsan vsan-id |
database vsan vsan-id}
Syntax Description
activate
|
Activates a port security database for the specified VSAN and automatically enables auto-learning.
|
auto-learn
|
Enables auto-learning for the specified VSAN.
|
database
|
Enters the port security database configuration mode for the specified VSAN.
|
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
force
|
(Optional) Forces the database activation.
|
no-auto-learn
|
(Optional) Disables the auto-learning feature for the port security database.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
When you activate the port security feature, the auto-learn option is also automatically enabled. You can choose to activate the port-security feature and disable auto-learning using the port-security activate vsan number no-auto-learn command. In this case, you need to manually populate the port security database by individually securing each port.
If the auto-learn option is enabled on a VSAN, you cannot activate the database for that VSAN without the force option.
Examples
The following example activates the port security database for the specified VSAN, and automatically enables auto-learning:
switch(config)# port-security activate vsan 1
The following example deactivates the port security database for the specified VSAN, and automatically disables auto-learning:
switch(config)# no port-security activate vsan 1
The following example disables the auto-learning feature for the port security database in VSAN 1:
switch(config)# port-security activate vsan 1 no-auto-learn
The following example enables auto-learning so the switch can learn about any device that is allowed to access VSAN 1. These devices are logged in the port security active database:
switch(config)# port-security auto-learn vsan 1
The following example disables auto-learning and stops the switch from learning about new devices accessing the switch:
switch(config)# no port-security auto-learn vsan 1
The following example enters the port security database mode for the specified VSAN:
switch(config)# port-security database vsan 1
switch(config-port-security)#
The following example forces the VSAN 1 port security database to activate even if there are conflicts:
switch(config)# port-security activate vsan 1 force
Related Commands
Command
|
Description
|
show port-security database
|
Displays configured port security information.
|
port-security abort
To discard the port security Cisco Fabric Services (CFS) distribution session in progress, use the port-security abort command.
port-security abort vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to discard a port security CFS distribution session in progress:
switch(config)# port-security abort vsan 33
Related Commands
Command
|
Description
|
port-security distribute
|
Enables CFS distribution for port security.
|
show port-security
|
Displays port security information.
|
port-security commit
To apply the pending configuration pertaining to the port security Cisco Fabric Services (CFS) distribution session in progress in the fabric, use the port-security commit command.
port-security commit vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to commit changes to the active port security configuration:
switch(config)# port-security commit vsan 13
Related Commands
Command
|
Description
|
port-security distribute
|
Enables CFS distribution for port security.
|
show port-security
|
Displays port security information.
|
port-security database
To copy the port security database or to view the difference within the port security database, use the port-security database command.
port-security database {copy | diff {active | config}} vsan vsan-id
Syntax Description
copy
|
Copies the active database to the configuration database.
|
diff
|
Provides the difference between the active and configuration port security database.
|
active
|
Writes the active database to the configuration database.
|
config
|
Writes the configuration database to the active database.
|
vsan vsan-id
|
Specifies the VSAN ID. The ranges is 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
If the active database is empty, the port-security database is empty. Use the port-security database diff active command to resolve conflicts.
Examples
The following example copies the active to the configured database:
switch# port-security database copy vsan 1
The following example provides the differences between the active database and the configuration database:
switch# port-security database diff active vsan 1
The following example provides information on the differences between the configuration database and the active database:
switch# port-security database diff config vsan 1
Related Commands
Command
|
Description
|
port-security database
|
Copies and provides information on the differences within the port security database.
|
show port-security database
|
Displays configured port security information.
|
port-security distribute
To enable Cisco Fabric Services (CFS) distribution for port security, use the port-security distribute command. To disable this feature, use the no form of the command.
port-security distribute
no port-security distribute
Syntax Description
This command has no other arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Before distributing the Fibre Channel timer changes to the fabric, the temporary changes to the configuration must be committed to the active configuration using the port-security commit command.
Examples
The following example shows how to distribute the port security configuration to the fabric:
switch(config)# port-security distribute
Related Commands
Command
|
Description
|
port-security commit
|
Commits the port security configuration changes to the active configuration.
|
show port-security
|
Displays port security information.
|
port-security enable
To enable port security, use the port-security enable command. To disable port security, use the no form of the command.
port-security enable
no port-security enable
Syntax Description
This command has no other arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Entering the port-security enable command enables the other commands that are used to configure port security.
Examples
The following example shows how to enable port security:
switch(config)# port-security enable
The following example shows how to disable port security:
switch(config)# no port-security enable
Related Commands
Command
|
Description
|
show port-security
|
Displays port security information.
|
port-track enable
To enable port tracking for indirect errors, use the port-track enable command. To disable this feature, use the no form of the command.
port-track enable
no port-track enable
Syntax Description
This command has no other arguments or keywords.
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The software brings the linked port down when the tracked port goes down. When the tracked port recovers from the failure and comes back up again, the tracked port is also brought up automatically (unless otherwise configured).
Examples
The following example shows how to enable port tracking:
switch(config)# port-track enable
The following example shows how to disable port tracking:
switch(config)# no port-track enable
Related Commands
Command
|
Description
|
show interface fc
|
Displays configuration and status information for a specified Fibre Channel interface.
|
show interface san-port-channel
|
Displays configuration and status information for a specified SAN port channel interface.
|
port-track force-shut
To force a shutdown of a tracked port, use the port-track force-shut command. To reenable the port tracking, use the no form of the command.
port-track force-shut
no port-track force-shut
Syntax Description
This command has no other arguments or keywords.
Command Default
None
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Use the port-track force-shut command to keep the linked port down, even though the tracked port comes back up. You must explicitly bring the port up when required using the no port-track force-shut command.
Examples
The following example shows how to force the shutdown of an interface and the interfaces that it is tracking:
switch(config)# interface fc 2/2
switch(config-if)# no port-track force-shut
Related Commands
Command
|
Description
|
port-track enable
|
Enables port tracking.
|
show interface fc
|
Displays configuration and status information for a specified Fibre Channel interface.
|
show interface san-port-channel
|
Displays configuration and status information for a specified SAN port channel interface.
|
port-track interface
To enable port tracking for specific interfaces, use the port-track interface command. To disable this feature, use the no form of the command.
port-track interface {fc slot/port | san-port-channel port} [vsan vsan-id]
no port-track interface {fc slot/port | san-port-channel port} [vsan vsan-id]
Syntax Description
fc slot/port
|
Specifies a Fibre Channel interface.
|
san-port-channel port
|
Specifies a SAN port channel interface. The range is 1 to 128.
|
vsan vsan-id
|
(Optional) Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
When the port that an interface is tracking goes down, the interface also goes down. When the tracked port comes back up, the linked interface also comes back up. Use the port-track force-shut command to keep the linked interface down.
Examples
The following example shows how to enable port tracking for specific interfaces:
switch(config)# interface fc 2/3
switch(config-if)# port-track interface san-port-channel 2
Related Commands
Command
|
Description
|
port-track enable
|
Enables port tracking.
|
port-track force-shut
|
Forcefully shuts an interface for port tracking.
|
show interface fc
|
Displays configuration and status information for a specified Fibre Channel interface.
|
show interface san-port-channel
|
Displays configuration and status information for a specified SAN port channel interface.
|
purge fcdomain fcid
To purge persistent FCIDs, use the purge fcdomain fcid command.
purge fcdomain fcid vsan vsan-id
Syntax Description
vsan vsan-id
|
Indicates that FCIDs are to be purged for a VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to purge all dynamic, unused FCIDs in VSAN 4:
switch# purge fcdomain fcid vsan 4
The following example shows how to purge all dynamic, unused FCIDs in VSANs 4, 5, and 6:
switch# purge fcdomain fcid vsan 4-6
rlir preferred-cond fcid
To specify a preferred host to receive Registered Link Incident Report (RLIR) frames, use the rlir preferred-cond fcid command. To remove a preferred host, use the no form of the command.
rlir preferred-cond fcid fc-id vsan vsan-id
no rlir preferred-cond fcid fc-id vsan vsan-id
Syntax Description
fcid fc-id
|
Specifies the FC ID. The format is 0xhhhhhh.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
Command Default
By default, the switch sends RLIR frames to one of the hosts in the VSAN with the register function set to "conditionally receive" if no hosts have the register function set to "always receive."
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The switch sends RLIR frames to the preferred host only if it meets the following conditions:
•
No host in the VSAN is registered for RLIR with the registration function set to "always receive." If one or more hosts in the VSAN are registered as "always receive," then RLIR sends only to these hosts and not to the configured preferred host.
•
The preferred host is registered with the registration function set to "conditionally receive." If all registered hosts have the registration function set to "conditionally receive," then the preferred host receives the RLIR frames.
You can specify only one RLIR preferred host per VSAN.
Examples
The following example specifies FC ID 0x654321 as the RLIR preferred host for VSAN 2:
switch(config)# rlir preferred-cond fcid 0x654321 vsan 2
The following example removes FC ID 0x654321 as the RLIR preferred host for VSAN 2:
switch(config)# no rlir preferred-cond fcid 0x654321 vsan 2
Related Commands
Command
|
Description
|
show rlir
|
Displays information about RLIR, Link Incident Record Registration (LIRR), and Distribute Registered Link Incident Record (DRLIR) frames.
|
clear rlir
|
Clears the RLIRs.
|
debug rlir
|
Enables RLIR debugging.
|
rscn
To configure a registered state change notification (RSCN), which is a Fibre Channel service that informs N ports about changes in the fabric, use the rscn command.
rscn {multi-pid | suppress domain-swrscn} vsan vsan-id
Syntax Description
multi-pid
|
Sends RSCNs in multiple port ID (multi-PID) format.
|
suppress domain-swrscn
|
Suppresses transmission of domain format SW-RCSNs.
|
vsan vsan-id
|
Configures VSAN information or membership. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example configures RSCNs in multi-PID format:
switch(config)# rscn multi-pid vsan 1
Related Commands
Command
|
Description
|
show rscn src-table
|
Displays state change registration table,
|
show rscn statistics
|
Displays RSCN statistics.
|
rscn abort
To cancel a Registered State Change Notification (RSCN) configuration on a VSAN, use the rscn abort command. To reverse the cancellation, use the no form of the command.
rscn abort vsan vsan-id
no rscn abort vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN where the RSCN configuration should be cancelled. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example cancels an RSCN configuration on VSAN 1:
switch(config)# rscn abort vsan 1
Related Commands
Command
|
Description
|
rscn commit
|
Commits a pending RSCN configuration on a specified VSAN.
|
rscn distribute
|
Enables the distribution of an RSCN configuration.
|
rscn event-tov
|
Configures an RSCN event timeout.
|
clear rscn session vsan
|
Clears the RSCN session for a specified VSAN.
|
show rscn
|
Displays RSCN configuration information.
|
rscn commit
To apply a pending Registered State Change Notification (RSCN) configuration, use the rscn commit command. To discard a pending RSCN configuration, use the no form of the command.
rscn commit vsan vsan-id
no rscn commit vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies a VSAN where the RSCN configuration should be committed. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
If you commit the changes made to the active database, the configuration is committed to all the switches in the fabric. On a successful commit, the configuration change is applied throughout the fabric and the lock is released.
Examples
The following example commits an RSCN configuration on VSAN 1:
switch(config)# rscn commit vsan 1
Related Commands
Command
|
Description
|
rscn abort
|
Cancels a pending RSCN configuration on a specified VSAN.
|
rscn distribute
|
Enables the distribution of an RSCN configuration.
|
rscn event-tov
|
Configures an RSCN event timeout.
|
clear rscn session
|
Clears the RSCN session for a specified VSAN.
|
show rscn
|
Displays RSCN configuration information.
|
rscn distribute
To enable distribution of a Registered State Change Notification (RSCN) configuration, use the rscn distribute command. To disable the distribution, use the no form of the command.
rscn distribute
no rscn distribute
Syntax Description
This command has no arguments or keywords.
Command Default
RSCN timer distribution is disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The RSCN timer configuration must be the same on all switches in the VSAN. Cisco Fabric Service (CFS) automatically distributes the RSCN timer configuration to all switches in a fabric. Only the RSCN timer configuration is distributed.
Examples
The following example enables the distribution of an RSCN configuration:
switch(config)# rscn distribute
Related Commands
Command
|
Description
|
rscn abort
|
Cancels a pending RSCN configuration on a specified VSAN.
|
rscn commit
|
Applies a pending RSCN configuration.
|
rscn event-tov
|
Configures an RSCN event timeout.
|
clear rscn session
|
Clears the RSCN session for a specified VSAN.
|
show rscn
|
Displays RSCN configuration information.
|
rscn event-tov
To configure an event timeout value for a Registered State Change Notification (RSCN) on a specified VSAN, use the rscn event-tov command. To cancel the event timeout value and restore the default value, use the no form of the command.
rscn event-tov timeout vsan vsan-id
no rscn event-tov timeout vsan vsan-id
Syntax Description
timeout
|
Specifies an event timeout value in milliseconds. The range is 0 to 2000.
|
vsan vsan-id
|
Specifies a VSAN where the RSCN event timer should be used. The ID of the VSAN is from 1 to 4093.
|
Command Default
The default timeout values are 2000 milliseconds for Fibre Channel VSANs.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Before changing the timeout value, you must enable RSCN configuration distribution using the rscn distribute command.
The RSCN timer is registered with Cisco Fabric Services (CFS) during initialization and switchover.
Examples
The following example configures an RSCN event timeout value on VSAN 1:
switch(config)# rscn event-tov 20 vsan 1
Related Commands
Command
|
Description
|
rscn abort
|
Cancels a pending RSCN configuration on a specified VSAN.
|
rscn commit
|
Applies a pending RSCN configuration.
|
rscn distribute
|
Enables distribution of an RSCN configuration.
|
clear rscn session
|
Clears the RSCN session for a specified VSAN.
|
show rscn
|
Displays RSCN configuration information.
|
san-port-channel persistent
To convert an autocreated SAN port channel to a persistent SAN port channel, use the san-port-channel persistent command.
san-port-channel port-channel-id persistent
Syntax Description
port-channel-id
|
Specifies the port channel ID. The range is 1 to 128.
|
persistent
|
Converts the autocreated SAN port channel to a persistent SAN port channel
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command is not reversible. A user-created channel group cannot be converted to an autocreated channel group.When the san-port-channel persistent command is applied to an autocreated channel group, the channel group number does not change and the member ports properties change to those of a user-created channel group. The channel mode remains active.
Examples
The following example shows how to change the properties of an autocreated channel group to a persistent channel group:
switch# san-port-channel 10 persistent
Related Commands
Command
|
Description
|
san-port-channel protocol
|
Enables the SAN port channel protocol.
|
show interface port-channel
|
Displays SAN port channel interface information.
|
show port-channel
|
Displays SAN port channel information.
|
scsi-target
To configure SCSI target discovery, use the scsi-target command. To remove SCSI target discovery, use the no form of the command.
scsi-target {auto-poll [vsan vsan-id] | discovery | ns-poll [vsan vsan-id] | on-demand [vsan
vsan-id]}
no scsi-target {auto-poll [vsan vsan-id] | discovery | ns-poll [vsan vsan-id] | on-demand [vsan
vsan-id]}
Syntax Description
auto-poll
|
Configures SCSI target auto-polling globally or per VSAN.
|
vsan vsan-id
|
Specifies a VSAN ID. The range is 1 to 4093.
|
discovery
|
Configures SCSI target discovery.
|
ns-poll
|
Configures SCSI target name-server polling globally or per VSAN.
|
on-demand
|
Configures SCSI targets on-demand globally or per VSAN.
|
Command Default
SCSI target discovery for each option is enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Automatic global SCSI target discovery is on by default. Discovery can also be triggered for specific VSANs using on-demand, name server polling, or auto-polling options. All options are on by default. Use the no scsi-target discovery command to turn off all discovery options. You can also turn off specific options by using the no form of the command.
Examples
The following example configures SCSI target auto-polling discovery for VSAN 1:
switch(config)# scsi-target auto-poll vsan 1
The following example removes SCSI target auto-polling discovery for VSAN 1:
switch(config)# no scsi-target auto-poll vsan 1
The following example configures a SCSI target discovery:
switch(config)# scsi-target discovery
The following example configures SCSI target ns-polling discovery for VSAN 1:
switch(config)# scsi-target ns-poll vsan 1
The following example removes SCSI target ns-polling discovery for VSAN 1:
switch(config)# no scsi-target ns-poll vsan 1
The following example configures SCSI target on-demand discovery for VSAN 1:
switch(config)# scsi-target on-demand vsan 1
The following example removes SCSI target on-demand discovery for VSAN 1:
switch(config)# no scsi-target on-demand vsan 1
Related Commands
Command
|
Description
|
discover scsi-target
|
Discovers SCSI targets on local storage to the switch or remote storage across the fabric.
|
show scsi-target
|
Displays information about existing SCSI target configurations.
|
switchport
To configure a switch port parameter on a Fibre Channel or virtual Fibre Channel interface, use the switchport command. To discard the configuration, use the no form of the command.
Fibre Channel Interface:
switchport { encap eisl |
fcrxbbcredit {credit [mode E | F ] | default | } |
mode {auto | E | F | SD | NP} |
speed {1000 | 2000 | 4000 | auto [max 2000]} |
trunk {allowed vsan {[add] vsan-id | all} | mode {auto | off | on}}}
no switchport { encap eisl | fcrxbbcredit| fcrxbufsize size | mode | rate | speed | trunk allowed
vsan [[add] vsan-id | all]}
Virtual Fibre Channel Interface:
switchport mode F
Syntax Description
encap eisl
|
Configures extended ISL (EISL) encapsulation for the interface.
|
fcrxbbcredit
|
Configures receive BB_credit for the port.
|
credit
|
Specifies receive BB_credit. The range is 1 to 255
|
mode
|
Configures receive BB_credit for the specific port mode.
|
E
|
Configures receive BB_credit for E or TE port mode.
|
F
|
Configures receive BB_credit for F port mode.
|
default
|
Configures default receive BB_credits depending on the port mode and capabilities.
|
mode
|
Configures the port mode.
|
auto
|
Configures autosense mode.
|
E
|
Configures E port mode.
|
F
|
Configures F port mode.
|
SD
|
Configures SD port mode.
|
NP
|
Configures N port proxy mode. NP mode is valid only when the switch is operating in NPV mode.
|
speed
|
Configures the port speed.
|
1000
|
Configures 1000-Mbps speed.
|
2000
|
Configures 2000-Mbps speed.
|
4000
|
Configures 4000-Mbps speed.
|
auto
|
Configures autosense speed.
|
max 2000
|
Configures 2-Gbps as the maximum bandwidth reserved in auto mode for 24-port and 48-port 4-Gbps switching module interfaces.
|
trunk
|
Configures trunking parameters on the interface.
|
allowed
|
Specifies the allowed list for interface(s).
|
vsan
|
Configures the VSAN range.
|
add
|
(Optional) Adds the VSAN ID to the range of allowed VSAN list
|
vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
all
|
Adds all the VSANs to allowed VSAN list.
|
mode
|
Configures the trunking mode.
|
auto
|
Configures automatic trunking mode.
|
off
|
Disables the trunking mode.
|
on
|
Enables the trunking mode.
|
Command Default
The EISL encapsulation is disabled.
The default receive data buffer size is 2112 bytes.
The port mode is auto.
The speed is auto.
The maximum auto speed is 2000.
The trunk mode is on.
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
You can specify a range of interfaces by entering a command with the following example format:
interface fc 1/1 - 5 , fc 2/5 - 7
The port speed on an interface determines the amount of shared resources available to the ports in the port group. Port group resources are reserved even though the bandwidth is not used. For example, if an interface is configured for autosensing (auto), then 4 Gbps of bandwidth is reserved even though the maximum operating speed is 2 Gbps. For the same interface, if autosensing with a maximum speed of 2 Gbps (auto max 2000) is configured, then only 2 Gbps of bandwidth is reserved and the unused 2 Gbps is shared with the other interface in the port group.
When configuring port modes, observe the following guidelines:
•
Auto port mode and E port mode cannot be configured in shared rate mode.
•
Shared to dedicated ports should be configured in this order: speed, port mode, credit.
•
Dedicated to shared ports should be configured in this order: credit, port mode, speed.
For a virtual Fibre Channel interface, you can set the port mode to F. The remaining switch port parameters are not configurable.
Examples
The following example configures switch port parameters for a Fibre Channel interface:
switch(config)# interface fc 2/3
switch(config-if)# switchport description techdocsSample
switch(config-if)# switchport mode E
switch(config-if)# switchport trunk mode auto
switch(config-if)# switchport trunk allowed vsan all
switch(config-if)# switchport trunk allowed vsan 3
switch(config-if)# switchport trunk allowed vsan add 2
switch(config-if)# switchport encap eisl
switch(config-if)# switchport fcrxbbcredit 20
The following example configures the mode of a virtual Fibre Channel interface:
switch(config)# interface vfc 2
switch(config-if)# switchport mode F
Related Commands
Command
|
Description
|
fcrxbbcredit extended enable
|
Enables extended BB_credits on the switch.
|
show interface
|
Displays an interface configuration for a specified interface.
|
switchport ignore bit-errors
To prevent the detection of bit error threshold events from disabling the interface on Fibre Channel interfaces, use the switchport ignore bit-errors command. To revert to the default, use the no form of the command.
switchport ignore bit-errors
no switchport ignore bit-errors
Syntax Description
This command has no arguments or keywords.
Command Default
None
Command Modes
Interface configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
The bit error rate threshold is used by the switch to detect an increased error rate before performance degradation seriously affects traffic.
Bit errors can occur for the following reasons:
•
Faulty or bad cable
•
Faulty or bad SFP
•
SFP is specified to operate at 1 Gbps but is used at 2 Gbps
•
Short haul cable is used for long haul or long haul cable is used for short haul
•
Momentary sync loss
•
Loose cable connection at one or both ends
•
Improper SFP connection at one or both ends
A bit error rate threshold is detected when 15 error bursts occur in a 5-minute period. By default, the switch disables the interface when the threshold is reached. You can enter a shutdown/no shutdown command sequence to reenable the interface.
Regardless of the setting of the switchport ignore bit-errors command, the switch generates a syslog message when bit error threshold events are detected.
Examples
The following example shows how to prevent the detection of bit error events from disabling the interface:
switch(config)# interface fc2/1
switch(config-if)# switchport ignore bit-errors
The following example shows how to allow the detection of bit error events from disabling the interface:
switch(config)# interface fc2/1
switch(config-if)# no switchport ignore bit-errors
Related Commands
Command
|
Description
|
show interface
|
Displays interface information.
|
system default switchport
To configure port attributes for Fibre Channel interfaces, use the system default switchport command. To disable port attributes, use the no form of the command.
system default switchport {shutdown | trunk mode {auto | off | on}}
no system default switchport {shutdown | trunk mode {auto | off | on}}
Syntax Description
shutdown
|
Disables or enables switch ports by default.
|
trunk
|
Configures the trunking parameters as a default.
|
mode
|
Configures the trunking mode.
|
auto
|
Enables autosense trunking.
|
off
|
Disables trunking.
|
on
|
Enables trunking.
|
Command Default
Enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Attributes configured using this command are applied globally to all future switch port configurations, even if you do not individually specify them at that time.
This command changes the configuration of the following ports to administrative mode F:
•
All ports that are down.
•
All F ports that are up, whose operational mode is F, and whose administrative mode is not F.
This command does not affect non-F ports that are up; however, if non-F ports are down, this command changes the administrative mode of those ports.
Examples
The following example shows how to configure port shutdown:
switch(config)# system default switchport shutdown
The following example shows how to configure the trunk mode:
switch(config)# system default switchport trunkmode auto
Related Commands
Command
|
Description
|
show system default switchport
|
Displays default values for switch port attributes.
|
show interface brief
|
Displays Fibre Channel port modes.
|
system default zone default-zone permit
To configure default values for a zone, use the system default zone default-zone permit command. To revert to the defaults, use the no form of the command.
system default zone default-zone permit
no system default zone default-zone permit
Syntax Description
This command has no arguments or keywords.
Command Default
No default values for zones.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command defines the default values for the default zone for all VSANs. The default values are used when you initially create a VSAN and it becomes active. If you do not want to use the default values, use the zone default-zone permit vsan command to define the operational values for the default zone.
The system default zone default-zone permit command should only be used in conjunction with VSANs that have not yet been created; it has no effect on existing VSANs.
Because VSAN 1 is the default VSAN and is always present, this command has no effect on it.
Examples
The following example sets the default zone to use the default values:
switch(config)# system default zone default-zone permit
The following example restores the default setting:
switch(config)# no system default zone default-zone permit
Related Commands
Command
|
Description
|
zone default-zone permit vsan
|
Defines whether a default zone (nodes not assigned a created zone) permits or denies access to all in the default zone.
|
show system default zone
|
Displays default values for the default zone.
|
system default zone distribute full
To configure default values for distribution to a zone set, use the system default zone distribute full command. To revert to the defaults, use the no form of the command.
system default zone distribute full
no system default zone distribute full
Syntax Description
This command has no arguments or keywords.
Command Default
Distribution to active zone sets only.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command distributes the default values for the default zone to all VSANs. The default values are used when you initially create a VSAN and it becomes active. If you do not want to use the default values, use the zoneset distribute full vsan command to distribute the operational values for the default zone.
The system default zone distribute full command should only be used in conjunction with VSANs that have not yet been created; it has no effect on existing VSANs.
Because VSAN 1 is the default VSAN and is always present, this command has no effect on it.
Examples
The following example distributes default values to the full zone set:
switch(config)# system default zone distribute full
The following example distributes default values to the active zone set only:
switch(config)# no system default zone distribute full
Related Commands
Command
|
Description
|
zoneset distribute full vsan
|
Distributes the operational values for the default zone to all zone sets.
|
show system default zone
|
Displays default values for the default zone.
|
trunk protocol enable
To configure the trunking protocol for Fibre Channel interfaces, use the trunk protocol enable command. To disable this feature, use the no form of the command.
trunk protocol enable
no trunk protocol enable
Syntax Description
This command has no other arguments or keywords.
Command Default
Enabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
If the trunking protocol is disabled on a switch, no port on that switch can apply new trunk configurations. Existing trunk configurations are not affected, and the TE port continues to function in trunking mode, but only supports traffic in VSANs that it negotiated previously (when the trunking protocol was enabled). Also, other switches that are directly connected to this switch are similarly affected on the connected interfaces. In some cases, you may need to merge traffic from different port VSANs across a nontrunking ISL. Before you merge traffic, you need to disable the trunking protocol.
Examples
The following example shows how to disable the trunk protocol feature:
switch(config)# no trunk protocol enable
The following example shows how to enable the trunk protocol feature:
switch(config)# trunk protocol enable
Related Commands
Command
|
Description
|
show trunk protocol
|
Displays the trunk protocol status.
|
vsan database
To create multiple fabrics sharing the same physical infrastructure, assign ports to VSANs, turn on or off interop mode, load balance either per originator exchange or by source-destination ID, and enter VSAN database mode, use the vsan database command. To remove a configuration, use the no command in VSAN database mode.
vsan database
vsan vsan-id
[interface {fc slot/port | san-port-channel port | vfc vfc-id} |
interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}] | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
vsan database
no vsan vsan-id
[interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] |
loadbalancing {src-dst-id | src-dst-ox-id} |
name name [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}] | suspend [interop [mode] [loadbalancing {src-dst-id |
src-dst-ox-id}] | loadbalancing {src-dst-id | src-dst-ox-id}] |
suspend [interop [mode] [loadbalancing {src-dst-id | src-dst-ox-id}] | loadbalancing
{src-dst-id | src-dst-ox-id}]]
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
interface fc slot/port
|
(Optional) Specifies the Fibre Channel interface by slot and port number on the switch.
|
san-port-channel portchannel-number. subinterface-number
|
Configures the SAN port channel interface specified by the SAN port channel number followed by a dot (.) indicator and the subinterface number.
|
vfc vfc-id
|
Specifies the virtual Fibre Channel interface.
|
interop
|
Turns on interoperability mode.
|
mode
|
Specifies the interop mode. The range is 1 to 4.
|
loadbalancing
|
Configures load-balancing scheme.
|
src-dst-id
|
Sets src-id/dst-id for load-balancing.
|
src-dst-ox-id
|
Sets ox-id/src-id/dst-id for load-balancing (default).
|
name name
|
Assigns a name to the VSAN. Maximum length is 32 characters.
|
suspend
|
Suspends the VSAN.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
To use this command, change to the VSAN database mode.
The interface range must be in ascending order and nonoverlapping. You can specify a range using a hyphen and several interfaces using commas:
•
The interface range format for a Fibre Channel interface range is
fcslot/port - port , fcslot/port , fcslot/port:
For example, show int fc2/1 - 3 , fc2/4 , fc3/2
•
The format for a SAN port channel is
san-port-channel portchannel-number.subinterface-number:
For example, show int san-port-channel 5.1
There are four interop modes:
•
Interop mode 1 — Standards based interop mode that requires all other vendors in the fabric to be in interop mode.
•
Interop mode 2 — Brocade native mode (Core PID 0).
•
Interop mode 3 — Brocade native mode (Core PID 1).
•
Interop mode 4 — McData native mode. Before you configure Interop mode 4 (or remove the configuration), you must suspend the VSAN. You should unsuspend the VSAN only after you configure a VSAN-dependent switch WWN with the McData OUI [08:00:88].
The no form of the vsan vsan-id interface command is not supported. To remove a VSAN membership of an interface (for example, interface fc1/8 from VSAN 7), you must assign the interface to another VSAN. The best practice is to assign the interface back to the default VSAN (VSAN 1).
Examples
The following example shows how to create multiple fabrics sharing the same physical infrastructure and how to assign ports to VSANs:
switch(config)# vsan database
switch-config-vsan-db# vsan 2
switch(config-vsan-db)# vsan 2 name TechDoc
switch(config-vsan-db)# vsan 2 loadbalancing src-dst-id
switch(config-vsan-db)# vsan 2 loadbalancing src-dst-ox-id
switch(config-vsan-db)# vsan 2 suspend
switch(config-vsan-db)# no vsan 2 suspend
switch(config-vsan-db)# end
The following example shows how to suspend a VSAN and enable Interop mode 4:
switch(config)# vsan database
switch(config-vsan-db)# vsan 100 suspend
switch(config-vsan-db)# vsan 100 interop 4
switch(config-vsan-db)# exit
Related Commands
Command
|
Description
|
wwn vsan
|
Configures a WWN for a suspended VSAN that has Interop mode 4 enabled.
|
wwn secondary-mac
To allocate a secondary MAC address to a SAN node, use the wwn secondary-mac command.
wwn secondary-mac wwn-id range address-range
Syntax Description
wwn-id
|
The secondary MAC address with the format hh:hh:hh:hh:hh:hh.
|
range address-range
|
The range for the specified WWN. The only valid value is 64.
|
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command cannot be undone.
Changes to the worldwide names are only performed as required. They should not be changed on a daily basis. These changes should be made by an administrator or individual who is completely familiar with switch operations.
For more information, refer to the Cisco Nexus 5000 Series CLI Configuration Guide.
Examples
The following example allocates a secondary range of MAC addresses:
switch(config)# wwn secondary-mac 00:99:55:77:55:55 range 64
wwn vsan
To configure a WWN for a suspended VSAN that has interop mode 4 enabled, use the wwn vsan command. To discard the configuration, use the no form of the command.
wwn vsan vsan-id vsan-wwn wwn
no wwn vsan vsan-id vsan-wwn wwn
Syntax Description
vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
vsan-wwn wwn
|
Specifies the WWN for the VSAN. The format is hh:hh:hh:hh:hh:hh:hh:hh.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
This command can succeed only if the following conditions are satisfied:
•
The VSAN must be suspended.
•
The VSAN must have interop mode 4 enabled before you can specify the switch WWN for it.
•
The switch WWN must be unique throughout the entire fabric.
•
The configured switch WWN must have McData OUI [08:00:88].
Examples
The following example shows how to assign a WWN to a VSAN:
switch(config)# wwn vsan 100 vsan-wwn 20:64:08:00:88:0d:5f:81
switch(config)# vsan database
switch(config-vsan-db)# vsan 100 suspend
switch(config-vsan-db)# exit
switch(config)# wwn vsan 100 vsan-wwn 20:64:08:00:88:0d:5f:81
Related Commands
Command
|
Description
|
vsan database
|
Creates multiple fabrics sharing the same physical infrastructure, assigns ports to a VSAN, turns on or off interop mode, and load balances either per originator exchange or source-destination ID.
|
zone clone
To clone a zone name, use the zone clone command.
zone clone current-zone-name new-zone-name vsan vsan-id
Syntax Description
current-zone-name new-zone-name
|
Clones a zone attribute group from the current name to a new name. Maximum length of names is 64 characters.
|
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Use the no form of the zone name (configuration mode) command to delete the zone name.
Examples
The following example creates a clone of the original zone group named origZone into the clone zone group cloneZone on VSAN 45:
switch(config)# zone clone origZone cloneZone vsan 45
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zone commit
To commit zoning changes to a VSAN, use the zone commit command. To negate the command, use the no form of the command.
zone commit vsan vsan-id [force]
no zone commit vsan vsan-id [force]
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
force
|
(Optional) Forces the commit.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Use the no form of the zone commit command to clear a session lock on a switch where the lock originated.
Examples
The following example commits zoning changes to VSAN 200:
switch(config)# zone commit vsan 200
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zone compact
To compact a zone database in a VSAN, use the zone compact command.
zone compact vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
8000 zones are supported in a Cisco Nexus 5000 Series switch.
If you attempt to merge VSANs, the merge will fail if more than 2000 zones are present in a VSAN and the neighboring VSAN cannot support more than 2000 zones.
Activation will fail if more than 2000 zones are present in the VSAN and one or more switches in the fabric cannot support more than 2000 zones.
Examples
The following example shows how to compact a zone database in VSAN 1:
switch(oongif)# zone compact vsan 1
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
show zone analysis
|
Displays detailed analysis and statistical information about the zoning database.
|
zone copy
To copy the active zone set to the full zone set, use the zone copy command. Use the no form of the command to negate the command or revert to the factory defaults.
zone copy active-zoneset full-zoneset [include-auto-zones] vsan vsan-id
zone copy vsan vsan-id active-zoneset {bootflash: | ftp: | full-zoneset | scp: | sftp: | tftp: |
volatile:}
no zone copy
Syntax Description
active-zoneset
|
Copies from the active zone set.
|
full-zoneset
|
Copies the active zone set to the full-zone set.
|
vsan vsan-id
|
Configures to copy active zone set on a VSAN to full zone set. The ID of the VSAN is from 1 to 4093.
|
bootflash:
|
Copies the active zone set to a location in the bootflash: directory.
|
ftp:
|
Copies the active zone set to a remote location using the FTP protocol.
|
scp:
|
Copies the active zone set to a remote location using the SCP protocol.
|
sftp:
|
Copies the active zone set to a remote location using the SFTP protocol.
|
slot0:
|
Copies the active zone set to a location in the slot0: directory.
|
tftp:
|
Copies the active zone set to a remote location using the TFTP protocol.
|
volatile:
|
Copies the active zone set to a location in the volatile: directory.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example copies the active zone set to the full zone set:
switch# zone copy active-zoneset full-zoneset vsan 1
The following example copies the active zone set in VSAN 3 to a remote location using SCP:
switch# zone copy vsan 3 active-zoneset scp://guest@myserver/tmp/active_zoneset.txt
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zone default-zone
To define whether a default zone (assigned to nodes not assigned to a created zone) permits or denies access to all nodes in the default zone, use the zone default-zone command. Use the no form of the command to negate the command or revert to the factory defaults.
zone default-zone permit vsan vsan-id
no zone default-zone permit vsan vsan-id
Syntax Description
permit
|
Permits access to all nodes in the default zone.
|
vsan vsan-id
|
Sets default zoning behavior for the specified VSAN. The ID of the VSAN is from 1 to 4093.
|
Command Default
All default zones are permitted access.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Use the zone default-zone permit vsan command to define the operational values for the default zone in a VSAN. This command applies to existing VSANs; it has no effect on VSANs that have not yet been created.
Use the system default zone default-zone permit command to use the default values defined for the default zone for all VSANs. The default values are used when you initially create a VSAN and it becomes active.
Examples
The following example permits default zoning in VSAN 2:
switch(config)# zone default-zone permit vsan 2
Related Commands
Command
|
Description
|
system default zone default-zone permit
|
Configures default values for a zone.
|
show zone
|
Displays zone information.
|
zone merge-control restrict vsan
To restrict zone database merging, use the zone merge-control restrict vsan command. To disable this feature, use the no form of the command.
zone merge-control restrict vsan vsan-id
no zone merge-control restrict vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
Release 4.0
|
This command was introduced.
|
Usage Guidelines
If merge control is set to restricted and the two databases are not identical, the merge fails and ISLs between the switches become isolated.
Examples
The following example shows how to set zone merge control for VSAN 10 to restricted:
switch(config)# zone merge-control restrict vsan 10
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zone mode enhanced
To enable enhanced zoning for a VSAN, use the zone mode enhanced command. To disable this feature, use the no form of the command.
zone mode enhanced vsan vsan-id
no zone mode enhanced vsan vsan-id
Syntax Description
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
Disabled.
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Before using the zone mode enhanced command, verify that all switches in the fabric are capable of working in enhanced zoning mode. If one or more switches are not capable of working in enhanced zoning mode, the request to enable enhanced zoning mode is rejected.
When the zone mode enhanced vsan command completes successfully, the software automatically starts a session, distributes the zoning database using the enhanced zoning data structures, applies the configuration changes, and sends a release change authorization (RCA) to all switches in the fabric. All switches in the fabric then enable enhanced zoning mode.
Examples
The following example shows how to enable enhanced zoning mode:
switch(config)# zone mode enhanced vsan 10
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zone name (configuration mode)
To create a zone, use the zone name command. Use the no form of the command to negate the command or revert to the factory defaults.
zone name zone-name vsan vsan-id
member
zone name zone-name vsan vsan-id
no member
no zone name zone-name vsan vsan-id
Syntax Description
zone-name
|
Specifies the name of the zone. Maximum length is 64 characters.
|
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Zones are assigned to zone sets. Zone sets are then activated from one switch and propagate across the fabric to all switches. Zones allow security by permitting and denying access between nodes (hosts and storage). zone name commands are entered from the configuration mode. Configure a zone for a VSAN from the config-zone mode.
Use the show wwn switch command to retrieve the switch world wide name (sWWN). If you do not provide an sWWN, the software automatically uses the local sWWN.
Examples
The following example configures attributes for the specified zone (Zone1) based on the member type (pWWN, fabric pWWN, FCID, or Fibre Channel alias) and value specified:
switch(config)# zone name Zone1 vsan 10
switch(config-zone)# member device-alias device1
The following example configures members for the specified zone (Zone2) based on the member type (pWWN, fabric pWWN, FCID, or Fibre Channel alias) and value specified:
switch(config)# zone name Zone2 vsan 10
switch(config-zone)# member fcalias Payroll
switch(config-zone)# member domain-id 2 portnumber 23
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zone rename
|
Renames zones.
|
zone-attribute-group name
|
Configures zone attribute groups.
|
zone name (zone set configuration mode)
To configure a zone in a zone set, use the zone name command in zone set configuration mode. To delete the zone from the zone set, use the no form of the command.
zone name zone-name
no zone name zone-name
Syntax Description
zone-name
|
Specifies the name of the zone. Maximum length is 64 characters.
|
Command Default
None
Command Modes
Zone set configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example configure a zone in a zone set:
switch(config)# zoneset name Sample vsan 1
switch(config-zoneset)# zone name MyZone
The following example deletes a zone from a zone set:
switch(config-zoneset)# no zone name Zone2
Related Commands
Command
|
Description
|
show zoneset
|
Displays zone set information.
|
zone name (configuration mode)
|
Configure zones.
|
zoneset
|
Configures zone set attributes.
|
zone rename
To rename a zone, use the zone rename command.
zone rename current-name new-name vsan vsan-id
Syntax Description
current-name
|
Specifies the current fcalias name. Maximum length is 64 characters.
|
new-name
|
Specifies the new fcalias name. Maximum length is 64 characters.
|
vsan vsan-id
|
Specifies the VSAN ID. The range is 1 to 4093.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Examples
The following example shows how to rename a zone:
switch# zone rename ZoneA ZoneB vsan 10
Related Commands
Command
|
Description
|
show zone
|
Displays zone information.
|
zone name
|
Creates and configures zones.
|
zoneset (configuration mode)
To group zones under one zone set, use the zoneset command. To negate the command or revert to the factory defaults, use the no form of the command.
zoneset {activate [name zoneset-name] vsan vsan-id | clone zoneset-currentName
zoneset-cloneName vsan vsan-id | distribute full vsan vsan-id name zoneset-name vsan
vsan-id | rename current-name new-name vsan vsan-id}
no zoneset {activate [name zoneset-name] vsan vsan-id | clone zoneset-currentName
zoneset-cloneName vsan vsan-id | distribute full vsan vsan-id name zoneset-name vsan
vsan-id | rename current-name new-name vsan vsan-id}
Syntax Description
activate
|
Activates a zone set
|
clone zoneset-currentName zoneset-cloneName
|
Clones a zone set from the current name to a new name. Maximum length of names is 64 characters.
|
name zoneset-name
|
(Optional) Specifies a name for a zone set. Maximum length is 64 characters.
|
distribute full
|
Enables zone set propagation.
|
vsan vsan-id
|
Activates a zone set on the specified VSAN. The range is 1 to 4093.
|
rename
|
Renames a zone set.
|
current-name
|
Specifies the current fcalias name.
|
new-name
|
Specifies the new fcalias name.
|
Command Default
None
Command Modes
Configuration mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
Zones are activated by activating the parent zone set.
The zoneset distribute full vsan command distributes the operational values for the default zone to all zone sets in a VSAN. If you do not want to distribute the operation values, use the system default zone distribute full command to distribute the default values.The default values are used when you initially create a VSAN and it becomes active.
The zoneset distribute full vsan command applies to existing VSANs; it has no effect on VSANs that have not yet been created.
Examples
The following example activates a zone set named zSet1 in VSAN 333:
switch(config)# zoneset activate name zSet1 vsan 333
The following example clones a zone set named zSet1 into a new zoneset named zSetClone in VSAN 45:
switch(config)# zoneset clone existing zSet1 zSetClone vsan 45
The following example distributes the operational values for the default zone to all zone sets in VSAN 22:
switch(config)# zoneset distribute full vsan 22
Related Commands
Command
|
Description
|
system default zone distribute full
|
Configures default values for distribution to a zone set
|
show zoneset
|
Displays zone set information.
|
zoneset (EXEC mode)
To merge zone set databases, use the zoneset command.
zoneset {distribute | export | import interface {fc slot/port | san-port-channel port-number}}
vsan vsan-id
Syntax Description
distribute
|
Distributes the full zone set in the fabric.
|
export
|
Exports the zone set database to the adjacent switch on the specified VSAN. The active zone set in this switch becomes the activated zone set of the merged SAN.
|
import
|
Imports the zone set database to the adjacent switch on the specified interface. The active zone set in the adjacent switch becomes the activated zone set of the merged SAN.
|
interface
|
Configures the interface.
|
fc slot/port
|
Configures a Fibre Channel interface for the specified slot number and port number.
|
san-port-channel port-number
|
Specifies SAN port channel interface.
|
vsan vsan-id
|
Merges the zone set database of a VSAN on the specified interface. The ID of the VSAN is from 1 to 4093.
|
Command Default
None
Command Modes
EXEC mode
Command History
Release
|
Modification
|
4.0(0)N1(1a)
|
This command was introduced.
|
Usage Guidelines
You can also enter the zoneset import and the zoneset export commands for a range of VSANs.
The zoneset distribute vsan vsan-id command is supported in interop 2 and interop 3 modes, and not in interop 1 mode.
Examples
The following example imports the zone set database from the adjacent switch connected through the VSAN 2 interface:
switch# zoneset import interface fc2/3 vsan 2
The following example exports the zone set database to the adjacent switch connected through VSAN 5:
switch# zoneset export vsan 5
The following example distributes the zone set in VSAN 333:
switch# zoneset distribute vsan 333
Related Commands
Command
|
Description
|
show zone status vsan
|
Displays the distribution status for the specified VSAN.
|
show zoneset
|