Cisco SFS 7000 Series Product Family Command Reference, Release 2.7.0
Diagnostic Commands

Table Of Contents

Diagnostic Commands

Running Diagnostic Tests

diagnostic

data-pattern

data-size

iterations

source-wwpn

start

stop

target-wwpn

test

validate


Diagnostic Commands


This chapter documents the following commands:

diagnostic

data-pattern

data-size

iterations

source-wwpn

start

stop

target-wwpn

test

validate

Running Diagnostic Tests

To perform a diagnostic test, follow these high-level steps:


Step 1 Enter the appropriate configuration submode for the port or card that you want to test.

Step 2 Configure the properties of the test:

data-pattern

data-size

iterations

source-wwpn (Fibre Channel only)

target-wwpn (Fibre Channel only)

Step 3 Configure the type of test:

internal-loopback

external-loopback

echo

self-test


Note Available test types vary by card type and interface type.


Step 4 Start and stop tests as needed. See the "start" section and the "stop" section.

diagnostic

To enter Diagnostic Configuration submode, enter the diagnostic command in Global Configuration mode.

diagnostic {card {card-selection | all} | chassis | interface {fc | ib | ethernet} {interface-selection

| all} | fan {fan-number | all} | power-supply {supply | all} | rack-locator {locator | all}}


Note Not all syntax applies to all hardware platforms. Enter Diagnostic submode to run test on cards and interfaces.


Syntax Description

card

Enters Card Diagnostic Configuration submode.

card-selection

Card, list of cards, or range of cards to diagnose.

chassis

Configures chassis-specific diagnostic tests.

fan

Configures fan-specific diagnostic tests.

interface

Enters Interface Diagnostic Configuration submode.

fc

Specifies Fibre Channel interfaces.

ib

Specifies InfiniBand interfaces.

ethernet

Specifies Ethernet interfaces.

interface-selection

Interface, list of interfaces, or range of interfaces to diagnose.

all

Specifies all interfaces of the technology type that you specified for all cards.

power-supply

Configures power supply-specific diagnostic tests.

rack-locator

Configures rack locator-specific diagnostic tests.


Defaults

This command has no default settings.

Command Modes

Global Configuration (config) mode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter


Note The SFS 3001 and SFS 3012 can run card and interface tests only. For the SFS 7000 and SFS 7008, the rack-locator keyword supports only 12x, not 4x.


Privilege Level:

Read-write user for the appropriate technology.

Examples

The following example enters Diagnostic Configuration submode for Ethernet port 2/1:

SFS-7000P(config)# diagnostic interface ethernet 2/1
SFS-7000P(config-diag-if-ether-2/1)#

Related Commands

show diagnostic
show card
start
stop
test

data-pattern

To specify a data pattern when you run a diagnostic test on an interfaces, enter the data-pattern command in Interface Diagnostic Configuration submode. To clear the data pattern, use the no form of this command.

data-pattern pattern

no data-pattern pattern

Syntax Description

pattern

Artificial traffic pattern to create for testing purposes.


Defaults

This command has no default settings.

Command Modes

Interface Diagnostic Configuration (config-diag-if) mode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Unrestricted and general read-write user.

Examples

The following example configures the data pattern that runs during a diagnostic test:

SFS-7000P(config-diag-if-fc-4/1)# data pattern 11:22:33:44

Related Commands

test
diagnostic
start
stop
show interface ethernet
show interface fc
show interface ib

data-size

Configure the data size property of your test to customize the size of packets, frames, or IB packets that your Server Switch uses for your test. To configure the payload size of an interface, enter the data-size command in Interface Diagnostic Configuration submode. To clear the data size, use the no form of this command.

data-size size

no data-size size

Syntax DescriptionConfiguration submode. To clear the data size, use the no form of this command.

size

Integer value that represents the payload size, in octets.


Data size defaults to 4 octets.

Command Modes

Interface Diagnostic Configuration submode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Unrestricted and general read-write user.

Examples

The following example configures the payload size for a diagnostic test:

SFS-7000P(config-diag-if-fc-4/1)# data size 8

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
start
stop
test

iterations

To specify the number of times to run a diagnostic test on an interface, enter the iterations command in Interface Diagnostic Configuration submode. If you do not specify a specific number of repetitions for a test to run, use the stop command.

iterations repetitions

Syntax Description

reptitions

Integer value for the number of times that you want a test to run.


Defaults

The iterations value defaults to zero, which causes the test to run until you stop it with the stop command.

Command Modes

Interface Diagnostic Configuration submode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Unrestricted and general read-write user.

Examples

The following example conconfigures diagnostic tests to run four times and then stop:

SFS-7000P(config-diag-if-fc-4/1)# iterations 4

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
start
stop
test

source-wwpn

To configure an optional WWPN identifier for a Fibre Channel interface Echo test, enter the source-wwpn command in Fibre Channel Interface Diagnostic Configuration submode.

source-wwpn wwpn

no source-wwpn wwpn

Syntax Description

wwpn

Optional 24-bit source identifier to use with the Fibre Channel interface Echo test.


Defaults

This command has no default settings.

Command Modes

Interface Diagnostic Configuration submode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Unrestricted and general read-write user.

Examples

The following example sets the source wwpn:

SFS-7000P(config-diag-if-fc-4/1)# source-wwpn 20:01:00:05:ad:00:40:00

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
start
stop
test

start

To begin a diagnostic test, enter the start command in the appropriate Interface DiagnosticConfiguration submode.

start

Syntax Description

This command has no arguments or keywords.

Defaults

This command has no default settings.

Command Modes

Fibre Channel Interface Diagnostic Configuration (config-diag-if-fc) submode, Ethernet Interface Diagnostic Configuration (config-diag-if-en) submode, or Card Interface Diagnostic Configuration (config-diag-if-card) submode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Unrestricted and general read-write user.

Examples

The following example starts a LED diag test on a Fibre Channel interface:

SFS-7000P(config-diag-if-fc-4/1)# test led
SFS-7000P(config-diag-if-fc-4/1)# start

The following example starts a self-test diagnostic test on a card:

FS-7000P (config-diag-card-6)# test self-test
SFS-7000P (config-diag-card-6)# start

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
stop
test

stop

To end a diagnostic test, enter the stop command in the appropriate Interface DiagnosticConfiguration submode.

stop

Syntax Description

This command has no arguments or keywords.

Defaults

This command has no default settings.

Command Modes

Fibre Channel Interface Diagnostic Configuration (config-diag-if-fc) submode, Ethernet Interface Diagnostic Configuration (config-diag-if-en) submode, or Card Interface Diagnostic Configuration (config-diag-if-card) submode, Card Diagnostic Configuration submode, (config-diag-card), Chassis Diagnostic Configuration submode (config-diag-chassis), Fan Diagnostic Configuration submode (config-diag-fan), Power Supply Diagnostic Configuration submode (config-diag-power-supply), Rack Locator Diagnostic Configuration submode (config-diag-rack-locator), InfiniBand Interface Diagnostic Configuration submode (config-diag-if-ib)

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Fibre Channelread-write user.

Examples

The following example stops the test running on Fibre Channel port 4/1:

SFS-7000P(config-diag-if-fc-4/1)# stop

The following example stops the test running on card 6:

FS-7000P (config-diag-card-6)# stop

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
start
test

target-wwpn

To configure an optional WWPN identifier for a Fibre Channel interface Echo test, enter the target-wwpn command in Fibre Channel Interface Diagnostic Configuration submode.

source-wwpn wwpn

no source-wwpn wwpn

Syntax Descriptionno source-wwpn wwpn

wwpn

Optional 24-bit source identifier to use with the Fibre Channel interface Echo test.


Defaults

This command has no default settings.

Command Modes

Configuration Diag Interface Fibre Channel (config-diag-if-fc) submode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Fibre Channelread-write user.

Examples

The following example enables database synchronization on the IB fabric:

SFS-7000P(config-diag-if-fc-4/1)# ib sm db-sync subnet-prefix fe:80:00:00:00:00:00:00 
enable

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
start
stop
test

test

Specify a diagnostic test to run with the test command in appropriate Diagnostic Configuration submode.

test {echo | int-loopback | ext-loopback | led | self-test}


Note The SFS 7000 does not support external loopback tests for InfiniBand interfaces. Table 7-8 describes the different tests that you can run and the interfaces or cards on which you can run them.


Syntax Description

echo

Echo test (Fibre Channel gateway only).

int-loopback

Internal loopback test (unsupported).

ext-loopback

External loopback test (Fibre Channel gateway only).

led

LED test.

self-test

Self test.

ext-cable

External cable test (unsupported).


Defaults

This command has no default settings.

Command Modes

Fibre Channel Interface Diagnostic Configuration (config-diag-if-fc) submode, Ethernet Interface Diagnostic Configuration (config-diag-if-en) submode, InfiniBand Interface Diagnostic Configuration

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

Read-write user.

Examples

The following example specifies a LED test to run on card 11 when the start command executes:

SFS-7000P (config-diag-card-11)# test LED

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
start
stop

validate

To validate diagnostic tests, enter the validate command in the appropriate Diagnostic Configuration submode.

validate

no validate

Syntax Description

This command has no arguments or keywords.

Defaults

This command has no default settings.

Command Modes

Diagnostic Configuration (config-diag) submode.

Usage Guidelines

Platform Availability:

Cisco SFS 3001, Cisco SFS 7000, Cisco SFS 7008, Cisco SFS 3012, Cisco 4x InfiniBand Switch Module for IBM BladeCenter

Privilege Level:

General read-write user.

Examples

The following example validates diagnostic tests on port 6/2:

SFS-7000P (config-diag-if-en-6/2)# validate

Related Commands

diagnostic
show interface ethernet
show interface fc
show interface gateway
start
stop