Cisco Active Network Abstraction Reference Guide, 3.7
Support Information for Cisco Syslogs

Table Of Contents

Support Information for Cisco Syslogs

Cisco ASR 9000 Syslogs

Cisco IOS Syslogs

Cisco IOX Syslogs

Cisco ASR 9000 Syslog Registry Parameters

Cisco IOS Syslog Registry Parameters

Cisco IOX Syslog Registry Parameters


Support Information for Cisco Syslogs


This chapter provides detailed information about the syslogs supported in Cisco ANA. It presents this information in two forms:

Syslog Tables: A section devoted to the supported syslogs for each NOS platform (e.g., Cisco ASR 9000 Syslogs). Each of these sections contains a table listing the name of each supported syslog, along with a description, the raw format of the syslog string, and a short description. In the syslog tables in this Reference, each syslog's short description is also a link to its corresponding registry parameters.

Registry Parameter Tables: A section devoted to the event types, event subtypes and Cisco ANA registry parameters for the supported syslogs. There is one parameter table for every syslog table (e.g., Cisco ASR 9000 Syslog Registry Parameters). Each syslog can have multiple event subtypes, or states. The parameter tables indicate when each state is generated, and how Cisco ANA processes them (such as their severity, whether they are ticketable, can be correlated, are autocleared, and so on).

This chapter includes the following sections:

Cisco ASR 9000 Syslogs

Cisco IOS Syslogs

Cisco IOX Syslogs

Cisco ASR 9000 Syslog Registry Parameters

Cisco IOS Syslog Registry Parameters

Cisco IOX Syslog Registry Parameters

Cisco ASR 9000 Syslogs

Table 37-1 lists the Cisco ASR 9000 Syslogs supported in Cisco ANA.

Table 37-1 Cisco ASR Syslogs 

Syslog Name
Description
Raw Format
Short Description

PLATFORM-PWRMON-4-OIR

handle power supply syslog

%PLATFORM-PWRMON-4-OIR : Power-module 0/PM0/SP inserted

Power supply inserted syslog

PLATFORM-PWRMON-4-OIR

handle power supply syslog

%PLATFORM-PWRMON-4-OIR : Power-module 0/PM0/SP removed

Power supply removed syslog

IP-VRRP-6-INFO_STATECHANGE

handle VRRP state change syslog

%IP-VRRP-6-INFO_STATECHANGE : GigabitEthernet0_5_0_1 vrid 10: state Backup -> Master

Backup to Master change syslog

IP-VRRP-6-INFO_STATECHANGE

handle VRRP state change syslog

%IP-VRRP-6-INFO_STATECHANGE : GigabitEthernet0_5_0_1 vrid 10: state Master -> Backup

Master to Backup change syslog

L2-BFD-4-RATE_LIMIT_WARNING_HIGH_WATERMARK

BFD rate limit high warning syslog

%L2-BFD-4-RATE_LIMIT_WARNING_HIGH_WATERMARK BFD PPS allocation exceeds 90 percent of maximum.

BFD rate limit high warning syslog

ROUTING-RIP-3-ERR_PAK_AUTH

RIP Authentication Failure syslog

%ROUTING-RIP-3-ERR_PAK_AUTH Authentication failure for RIP [chars] packet in context [chars]: instance [chars]: error equals [chars]

RIP authentication failed syslog

ROUTING-RIP-3-ERR_CFG

RIP configuration error syslog

%ROUTING-RIP-3-ERR_CFG Error during configuration in context [chars]: error equals [chars]

RIP configuration error syslog

ROUTING-RIP-6-INFO_OOM

RIP out of memory event syslog

%ROUTING-RIP-6-INFO_OOM RIP out-of-memory event [chars]: new/current state equals [chars]: old state equals [chars]

RIP out of memory event syslog

ROUTING-ISIS-5-ADJCHANGE

handle ROUTING-ISIS-5-ADJCHANGE syslog

RP/0/RSP1/CPU0:Oct 19 19:48:32.212 : isis[240]: %ROUTING-ISIS-5-ADJCHANGE : Adjacency to AGS2a (Bundle-Ether1) (L1) Down, Interface state down

routing ISIS neighbor down syslog

ROUTING-ISIS-5-ADJCHANGE

handle ROUTING-ISIS-5-ADJCHANGE syslog

RP/0/RSP1/CPU0:Oct 19 19:48:32.212 : isis[240]: %ROUTING-ISIS-5-ADJCHANGE : Adjacency to AGS2a (Bundle-Ether1) (L1) Up, Interface state up

routing ISIS neighbor up syslog


Cisco IOS Syslogs

Table 37-2 lists the Cisco IOS syslogs supported in Cisco ANA.

Table 37-2 Cisco IOS Syslogs 

Syslog Name
Description
Raw Format
Short Description

LINK-5-CHANGED

handle link down syslog

%LINK-5-CHANGED: Interface Ethernet5/1, changed state to administratively up

Link down syslog

LINK-5-CHANGED

handle link down syslog

%LINK-5-CHANGED: Interface Ethernet5/1, changed state to administratively down

Link up syslog

FR-5-DLCICHANGE

handle dlci change syslog

%FR-5-DLCICHANGE: Interface Serial3/0/0:1 - DLCI 105 state changed to INACTIVE

FR DLCI down syslog

FR-5-DLCICHANGE

handle dlci change syslog

%FR-5-DLCICHANGE: Interface Serial3/0/0:1 - DLCI 105 state changed to ACTIVE

FR DLCI up syslog

STANDBY-6-STATECHANGE

handle hsrp syslog

%STANDBY-6-STATECHANGE: Standby: 1: Ethernet1 state Active -> Standby

HSRP group change syslog

STANDBY-6-STATECHANGE

handle hsrp syslog

%STANDBY-6-STATECHANGE: Standby: 1: Ethernet1 state Active -> Speak

HSRP group restored syslog

SNMP-5-SNMPAUTHFAIL

This message indicates that the switch has received an SNMP message that was not properly authenticated

%SNMP-5-SNMPAUTHFAIL: Authentication failed for message from 192.168.1.2

SNMP message has not properly authenticated

SYS-2-MALLOCFAIL

The requested memory allocation is not available from the specified memory pool

%SYS-2-MALLOCFAIL: Memory allocation of 1028 bytes failed from 0x6015EC84, Pool Processor, alignment 0

Memory allocation is not available

SYS-3-CPUHOG

The indicated process ran too long without relinquishing the processor

%SYS-3-CPUHOG: Task ran for 2148 msec (20/13), Process = IP Input, PC = 3199482 -Traceback= 314B5E6 319948A

process ran too long

SCHED-3-STUCKMTMR

A process can register to be notified when various events occur in the router. This message indicates that a registered timer is expired and its value is unchanged after the process has executed two successive times

%SCHED-3-STUCKMTMR: Sleep with expired managed timer 1C7410, time 0x1063F9C52 (00:00:00 ago).

registered timer is expired

DUAL-3-SIA

The EIGRP router hasn't received a reply to a query from one or more neighbors within the time allotted, so it clears the neighbors that didn't send a reply

%DUAL-3-SIA: Route 10.1.2.0/24 stuck-in-active state in IP-EIGRP 1. Cleaning up

EIGRP router query to neighbors timeouted syslog

LANCE-3-BADCABLE

The Ethernet cable is not connected

%LANCE-3-BADCABLE: msgtxt_badcable

Ethernet cable is not connected

LAPB-4-CTRLBAD

A received FRMR has reported a frame with an invalid control code

%LAPB-4-CTRLBAD: Interface Ethernet0, Invalid control field

frame with an invalid control code

DTP-5-NONTRUNKPORTON

The interface changed to non trunk

%DTP-5- ONTRUNKPORTON:Port 8/1 has become trunk

Interface changed to non trunk

DTP-5-NONTRUNKPORTON

The interface changed to non trunk

%DTP-5- ONTRUNKPORTON:Port 8/1 has become non trunk

Interface changed to trunk

LINEPROTO-5-UPDOWN

handle line syslog

%LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed state to down

Line down syslog

LINEPROTO-5-UPDOWN

handle line syslog

%LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed state to up

Line up syslog

IPX-3-BADIGRPSAP

A hardware or software error occurred

%IPX-3-BADIGRPSAP: Cannot send incremental SAP update to peer on interface Ethernet0. Increasing output-sap-delay may help

Cannot send incremental SAP update to peer

LANCE-5-COLL

An Ethernet cable is broken or unterminated, or the transceiver is unplugged

%LANCE-5-COLL: Unit 1, excessive collisions. TDR=10

An Ethernet cable is broken or unterminated

LANCE-5-LATECOLL

An Ethernet transceiver is unplugged or defective

%LANCE-5-LATECOLL: Unit 1, late collision error

An Ethernet transceiver is unplugged or defective

SYS-5-CONFIG_I

The router's configuration was changed

%SYS-5-CONFIG_I: Configured from console by console

Device configuration changed

AT-6-NODEWRONG

An AppleTalk node sent a GetNet Info request to this router specifying an invalid network number for the source of the GetNet Info request

%AT-6-NODEWRONG: XX: AppleTalk node 192.168.2.0 misconfigured; reply has been broadcast

AppleTalk invalid network number

SECURITY-1-PORTSHUTDOWN

This message indicates that a port has been shut down due to an insecure host sourcing a packet into that port

%Security-1-PORTSHUTDOWN: Port 0/1 shutdown due to security violation

security port shut down

SPANTREE-2-RX_PORTFAST

A BPDU that has spanning-tree portfast enabled was received on the specified interface

%SPANTREE-2-RX_PORTFAST:Received BPDU on PortFast enabled port. Disabling 2/1

BPDU spanning-tree portfast enabled

UDLD-3-DISABLE

This message indicates that a fault has been detected in a fiber Ethernet port connection and that the port has been disabled to prevent other protocols from malfunctioning

%UDLD-3-DISABLE: Unidirectional link detected on port 1/2. Port disabled

Fault has been detected in a fiber Ethernet port connection

UDLD-3-DISABLEFAIL

This message indicates that a fault was detected in the wiring on a fiber Ethernet port, but UDLD could not disable the port

%UDLD-3-DISABLEFAIL: Unidirectional link detected on port 1/2, failed to disable port

Unidirectional link detected

UDLD-4-ONEWAYPATH

This message indicates that a fault has been detected in a fiber Ethernet connection in a shared media environment and that the connection may cause a possible malfunction

%UDLD-4-ONEWAYPATH: A unidirectional link from port 1/2 to port 1/2 of device abc was detected

Fault has been detected in a fiber Ethernet connection

OSPF-5-ADJCHG

handle ospf syslog

%OSPF-5-ADJCHG: Process 1, Nbr 10.100.12.6 on FastEthernet1/0 from Up to DOWN, Loading Done

OSPF neighbor down syslog

OSPF-5-ADJCHG

handle ospf syslog

%OSPF-5-ADJCHG: Process 1, Nbr 10.100.12.6 on FastEthernet1/0 from LOADING to FULL, Loading Done

OSPF neighbor up syslog

SPANTREE-2-LOOPGUARDBLOCK

When the loop guard blocks an inconsistent port, the following message is logged

%SPANTREE-2-LOOPGUARDBLOCK: No BPDUs were received on port 3/2 in vlan 3. Moved to loop-inconsistent state

No BPDUs were received on port

SPANTREE-2-LOOPGUARDUNBLOCK

After the recovery, the following message is logged

%SPANTREE-2-LOOPGUARDUNBLOCK: port 3/2 restored in vlan 3

BPDUs were received on port

AMDP2_FE-5-COLL

Ethernet or Fast Ethernet is seeing multiple collisions. This problem may occur under heavy loads

%AMDP2_FE-5-COLL: AMDP2/FE Ethernet1/1, Excessive collisions, TDR=1, TRC=1

Ethernet is seeing multiple collisions

DEC21140-5-COLL

A Fast Ethernet packet has been dropped because too many attempts to transmit it were stopped by collisions

%DEC21140-5-COLL: unit 0, excessive collisions

Fast Ethernet packet has been dropped

ILACC-5-COLL

An Ethernet cable is broken or is not terminated, or the transceiver is unplugged

%ILACC-5-COLL: Unit 0, excessive collisions. TDR=0.12

An Ethernet cable is broken

PQUICC-5-COLL

PQUICC-5-COLL : An Ethernet cable is broken or is not terminated

%PQUICC-5-COLL: Unit 1, excessive collisions. Retry limit 12 exceeded

pquicc 5 coll syslog: An Ethernet cable is broken

PQUICC_ETHER-5-COLL

PQUICC_ETHER-5-COLL : An Ethernet cable is broken or is not terminated

%PQUICC_ETHER-5-COLL: Unit 1, excessive collisions. Retry limit 2 exceeded

pquicc ether 5 coll syslog: An Ethernet cable is broken

PQUICC_FE-5-COLL

Ethernet or Fast Ethernet is detecting multiple collisions

%PQUICC_FE-5-COLL: PQUICC/FE(0/1), Excessive collisions, TDR=10, TRC=10.

Ethernet is detecting multiple collisions

QUICC_ETHER-5-COLL

An Ethernet cable is broken or unterminated

%PQUICC_ETHER-5-COLL: Unit 1, excessive collisions. Retry limit 2 exceeded

quicc ether 5 coll syslog: An Ethernet cable is broken

AMDP2_FE-5-LATECOLL

Late collisions have occurred on the Ethernet or Fast Ethernet

%AMDP2_FE-5-LATECOLL: Ethernet1/1 transmit error

Late collisions have occurred

CLNS-5-ADJCHANGE

handle isis syslog

%CLNS-5-ADJCHANGE: ISIS: Adjacency to edge-02(POS0/0) Down, hold time expired

IS-IS neighbor down syslog

CLNS-5-ADJCHANGE

handle isis syslog

%CLNS-5-ADJCHANGE: ISIS: Adjacency to edge-02(POS0/0) Up, hold time expired

IS-IS neighbor up syslog

DEC21140-5-LATECOLL

Late collisions are collisions that occur after transmitting the preamble

%DEC21140-5-LATECOLL: FastEthernet0/0 transmit error

Late collisions have occurred

ILACC-5-LATECOLL

An Ethernet transceiver is malfunctioning, the Ethernet is overloaded, or the Ethernet cable is too long

%ILACC-5-LATECOLL: Unit 0, late collision error

ilacc 5 late coll syslog: Late collisions have occurred

PQUICC-5-LATECOLL

pquicc 5 late coll syslog

%PQUICC-5-LATECOLL: Unit 1, late collision error

pquicc 5 late coll syslog: Late collisions have occurred

PQUICC_ETHER-5-LATECOLL

PQUICC_ETHER-5-LATECOLL : A new network may not have been engineered properly or adding a regenerator to an existing network may have changed the network specifications

%PQUICC_ETHER-5-LATECOLL: Unit 0, late collision error

A new network may not have been engineered properly

PQUICC_FE-5-LATECOLL

Late collisions have occurred on the Ethernet or Fast Ethernet interface

%PQUICC_FE-5-LATECOLL: PQUICC/FE(0/1), Late collision

pquicc fe 5 late coll syslog: Late collisions have occurred

QUICC_ETHER-5-LATECOLL

QUICC_ETHER-5-LATECOLL : A software or hardware error occurred

%QUICC_ETHER-5-LATECOLL: Unit 0, late collision error

quicc ether 5 late coll syslog: Late collisions have occurred

SNMP-5-LINKTRAP

This message indicates the type of Link Trap

%SNMP-5-LINKTRAP: Link down Trap -- ifName=sc0

Link trap down has occurred

SNMP-5-LINKTRAP

This message indicates the type of Link Trap

%SNMP-5-LINKTRAP: Link up Trap -- ifName=sc0

Link trap up has occurred

SNMP-5-TOPOTRAP

his message indicates that a configured port changed from the learning state to the forwarding state, or from the forwarding state to the blocking state

%SNMP-5-TOPOTRAP: Topology Change Trap for VLAN 1

configured port changed state from learning to forwarding

DUAL-5-NBRCHANGE

handle eigrp syslog

%DUAL-5-NBRCHANGE: IP-EIGRP 1: Neighbor 10.1.4.3 (Serial0) is down: stuck in active

DUAL 5 neighbor down syslog

DUAL-5-NBRCHANGE

handle eigrp syslog

%DUAL-5-NBRCHANGE: IP-EIGRP 1: Neighbor 10.1.4.3 (Serial0) is up: stuck in active

DUAL 5 neighbor up syslog

LINK-3-UPDOWN

handle link down syslog

%LINK-3-UPDOWN: Interface ATM2/0, changed state to down

Link down syslog

LINK-3-UPDOWN

handle link down syslog

%LINK-3-UPDOWN: Interface ATM2/0, changed state to up

Link up syslog

BGP-5-ADJCHANGE-vrf

handle BGP 5 syslog from vrf. make sure it is before the "BGP-5-ADJCHANGE" pattern

%BGP-5-ADJCHANGE: neighbor 10.1.2.3 vpn vrf inet Down

BGP neighbor down syslog

BGP-5-ADJCHANGE-vrf

handle BGP 5 syslog from vrf. make sure it is before the "BGP-5-ADJCHANGE" pattern

%BGP-5-ADJCHANGE: neighbor 10.1.2.3 vpn vrf inet Up

BGP neighbor up syslog

BGP-5-ADJCHANGE

handle BGP 5 syslog

%BGP-5-ADJCHANGE: neighbor 161.10.11.1 Down

BGP neighbor down syslog

BGP-5-ADJCHANGE

handle BGP 5 syslog

%BGP-5-ADJCHANGE: neighbor 161.10.11.1 Up

BGP neighbor up syslog

OIR-6-(REM|INS)CARD

handle module out syslog

%OIR-6-INSCARD: Card inserted from slot 4, interfaces disabled

card in syslog

OIR-6-(REM|INS)CARD

handle module out syslog

%OIR-6-REMCARD: Card removed from slot 4, interfaces disabled

card out syslog

OIR-SP-3-PWRCYCLE

card being power cycled

%OIR-SP-3-PWRCYCLE: Card in module x, is being power-cycled off (Module not responding to Keep Alive polling)

oir sp 3 power cycle syslog

SYS-5-RELOAD

syslog for reloading the device

%SYS-5-RELOAD: Reload requested

Reloading device syslog

SYS-5-RESTART

syslog for restarting the device

%SYS-5-RESTART: System restarted --

System restart

DTP-5-TRUNKPORTON

The interface returned to be a trunk

%DTP-5-TRUNKPORTON:Port 7/2 has become interface trunk

Interface changed to non trunk

DTP-5-TRUNKPORTON

The interface returned to be a trunk

%DTP-5-TRUNKPORTON:Port 7/2 has become dot1q trunk

Interface changed to trunk

ISDN-6-CONNECT

handle ISDN connect syslog

%ISDN-6-CONNECT: Interface BRI0/0:1 is now connected to 5772223

ISDN connect syslog

ISDN-6-CONNECT

handle ISDN connect syslog

%ISDN-6-CONNECT: Interface BRI0/0:1 is now connected to 5772223

ISDN disconnect syslog

ISDN-6-DISCONNECT

handle ISDN connect syslog

%ISDN-6-DISCONNECT: Interface BRI0:1? disconnected from 8130 traxbol, call lasted 60 seconds

ISDN connect syslog

ISDN-6-DISCONNECT

handle ISDN connect syslog

%ISDN-6-DISCONNECT: Interface BRI0:1? disconnected from 8130 traxbol, call lasted 60 seconds

ISDN disconnect syslog

CDP-4-DUPLEX_MISMATCH

This messages indicates a duplex mismatch problem (IOS)

%CDP-4-DUPLEX_MISMATCH: duplex mismatch discovered on FastEthernet6/2 (not half duplex), with TBA04251336 3/2 (half duplex)

Duplex mismatch discovered

ISDN-6-CONNECT-2

handle ISDN connect syslog2

%ISDN-6-LAYER2UP: Layer 2 for Interface FastEthernet2/1, TEI 0 changed to up

ISDN connect syslog

ISDN-6-CONNECT-2

handle ISDN connect syslog2

%ISDN-6-DISCONNECT: Interface FastEthernet0/1 disconnected from 71017 , call lasted 22 seconds

ISDN disconnect syslog

ISDN-6-DISCONNECT-2

handle ISDN disconnect syslog2

%ISDN-6-LAYER2UP: Layer 2 for Interface FastEthernet2/1, TEI 0 changed to up

ISDN connect syslog

ISDN-6-DISCONNECT-2

handle ISDN disconnect syslog2

%ISDN-6-LAYER2DOWN: Layer 2 for Interface FastEthernet0/1, TEI 0 changed to down

ISDN disconnect syslog

LDP-5-NBRCHG-TDP

handle LDP Neighbor change syslog

%LDP-5-NBRCHG: TDP Neighbor 10.12.12.12:0 is DOWN (TCP connection closed by peer)

TDP neighbor down syslog

LDP-5-NBRCHG-TDP

handle LDP Neighbor change syslog

%LDP-5-NBRCHG: TDP Neighbor 10.12.12.12:0 is UP (TCP connection closed by peer)

TDP neighbor up syslog

LDP-5-NBRCHG-LDP

handle LDP Neighbor change syslog

%LDP-5-NBRCHG: LDP Neighbor 10.12.12.12:0 is DOWN

LDP neighbor down syslog

LDP-5-NBRCHG-LDP

handle LDP Neighbor change syslog

%LDP-5-NBRCHG: LDP Neighbor 10.12.12.12:0 is UP

LDP neighbor up syslog

MPLS_TE-5-TUN_reoptimize

handle tunnel reoptimization syslog

%MPLS_TE-5-TUN: Tun1002: installed LSP 1002_33 (popt 10) for 1002_32 (popt 20), reopt. LSP is up

MPSL-TE tunnel reoptimized/rerouted syslog

MPLS_TE-5-TUN_up

handle tunnel up syslog

%MPLS_TE-5-TUN: Tun0: installed LSP 0_26 (popt 5) for nil, got 1st feasible path opt

MPLS TE tunnel down syslog

MPLS_TE-5-TUN_up

handle tunnel up syslog

%MPLS_TE-5-TUN: Tun0: installed LSP 0_26 (popt 5) for nil, got 1st feasible path opt

MPLS TE tunnel up syslog

MPLS_TE-5-TUN_down

handle tunnel down syslog

%MPLS_TE-5-TUN: Tun1001: installed LSP nil for 1001_92 (popt 1), path verification failed

MPLS TE tunnel down syslog

MPLS_TE-5-TUN_down

handle tunnel down syslog

%MPLS_TE-5-TUN: Tun1001: installed LSP nil for 1001_92 (popt 1), path verification failed

MPLS TE tunnel up syslog

ENV_MON-2-SUPPLY

Power supply is not working or has not been turned on

%ENV_MON-2-SUPPLY : [chars] Power Supply is Operation or Non-Operational

A power supply is not working or has not been turned on

SYS-SP-STDBY-5-RESTART

restarting the device

%SYS-SP-STDBY-5-RESTART: System restarted -- Cisco IOS Software (c7600s72033-ADVENTERPRISEK9_WAN_MZ), Version 12.2 Copyright (c) 1986-2006 by Cisco Systems, Inc.Compiled Thu 26-Oct-06 03:49 by

System restart

UDLD-SP-4-UDLD_PORT_DISABLED

aggressive mode failure detected

%UDLD-SP-4-UDLD_PORT_DISABLED: UDLD disabled interface FastEthernet2/1, FastEthernet2/1

Aggressive Mode Failure Detected

FABRIC-SP-5-FABRIC_MODULE_BACKUP

clear block option

%FABRIC-SP-5-FABRIC_MODULE_BACKUP: The Switch Fabric Module in slot 6 became standby

fabric sp 5 clear block down syslog

FABRIC-SP-5-FABRIC_MODULE_BACKUP

clear block option

%FABRIC-SP-5-FABRIC_MODULE_BACKUP: The Switch Fabric Module in slot 6 became standby

fabric sp 5 clear block up syslog

C6KENV-SP-4-FANTRAYFAILED

fan tray failed

%C6KENV-SP-4-FANTRAYFAILED: fan tray 2 failed

c6kenv sp 4 fan tray fail syslog

PFREDUN-SP-4-BOOTSTRING_INVALID

bootstring invalid

PFREDUN-SP-4-BOOTSTRING_INVALID: The bootfile slavebootflash:image_name is not present in standby

pfredun sp 4 bootstring invalid syslog

SYS-5-POWER-SUPPLY

Power supply failure notification

Power supply [dec] failed

Power supply failed syslog

SYS-5-POWER-SUPPLY

Power supply failure notification

Power supply [dec] okay

Power supply okay syslog

PM-SP-STDBY-4-ERR_DISABLE

err disable state

%PM-SP-STDBY-4-ERR_DISABLE: bpduguard error detected on Gi2/5, putting Gi2/5 in err-disable state

pm sp stdby 4 err disable syslog

HSRP-6-STATECHANGE

handle hsrp syslog

%HSRP-6-STATECHANGE:FastEthernet0/0 Grp 1 state Init

HSRP group change syslog

HSRP-6-STATECHANGE

handle hsrp syslog

%HSRP-6-STATECHANGE:FastEthernet0/0 Grp 1 state Standby

HSRP group restored syslog

BGP-3-NOTIFICATION

handle BGP 3 syslog

%BGP-3-NOTIFICATION: sent to neighbor 10.10.10.254 4/0 (hold time expired) 0 bytes

BGP notification syslog

NEW-INTERFACE-FOR-VSL-CONNECTION

new interface for the VSL connection syslog (one of the ether channel interfaces)

%VSL-5-VSL_CNTRL_LINK: New VSL Control Link 8/4

new ethernet channel interface for VSL connection

VSL-LINK-UP

VSL link up syslog

%VSLP-5-VSL_UP: Ready for Role Resolution with Switch=1, MAC=0014.1bc6.1c00 over 8/4

VSL link up syslog

VSL-LINK-DOWN

VSL link down syslog

%VSLP-SW1_SP-2-VSL_DOWN: Last VSL interface Te1/6/4 went down

VSL link down syslog

VSL-LINK-UP

VSL link up syslog and active switch is #1

%VSLP-SW1_SP-5-VSL_UP: Ready for Role Resolution with Switch=2, MAC=0013a.30e1.6800 over Te1/5/5

VSL link up syslog: active switch is #1

VSL-LINK-UP

VSL link up syslog and active switch is #2

%VSLP-SW2_SP-5-VSL_UP: Ready for Role Resolution with Switch=2, MAC=0013a.30e1.6800 over Te1/5/5

VSL link up syslog: active switch is #2

VSL-ROLE-MISMATCH-RESOLVED

role mismatch resolved syslog, sent from active switch #1

%VSLP-SW1_SP-5-RRP_ROLE_RESOLVED: Role resolved as ACTIVE by VSLP

role mismatch resolved syslog, sent from active switch #1

VSL-ROLE-MISMATCH-RESOLVED

role mismatch resolved syslog, sent from active switch #2

%VSLP-SW2_SP-5-RRP_ROLE_RESOLVED: Role resolved as ACTIVE by VSLP

role mismatch resolved syslog, sent from active switch #2

ENV-SP-4-FANTRAYFAILED

fan tray failed

%C7600_ENV-SP-4-FANTRAYFAILED: fan tray 2 failed

env sp 4 fan tray fail syslog

PWR-SP-2-PSFAIL

power supply failed

%C7600_PWR-SP-2-PSFAIL: power supply 1 output failed.

pwr sp 2 power supply fail syslog

BGP-5-ADJCHANGE-bfd

handle BGP 5 syslogs for BFD

%BGP-5-ADJCHANGE: neighbor 192.168.20.1 Down BFD adjacency down

BGP neighbor down syslog

BGP-5-ADJCHANGE-bfd

handle BGP 5 syslogs for BFD

%BGP-5-ADJCHANGE: neighbor 192.168.20.1 UP BFD adjacency up

BGP neighbor up syslog

VRRP-6-STATECHANGE

Virtual Router Redundancy Protocol (VRRP) message: The VRRP router has changed state.

%VRRP-6-STATECHANGE: Fa0/1 Grp 1 state Backup -> Master

VRRP State Changed syslog

ATM_AIM-5-ACTIVE_LINK_(DOWN|UP)

The specified link in the specified IMA group has become inactive/active

%ATM_AIM-5-ACTIVE_LINK_DOWN: Interface ATM1/0 of IMA Group ATM0/IMA2 is now inactive

Ima Link Status Change Down Syslog

ATM_AIM-5-ACTIVE_LINK_(DOWN|UP)

The specified link in the specified IMA group has become inactive/active

%ATM_AIM-5-ACTIVE_LINK_UP: Interface ATM1/0 of IMA Group ATM0/IMA2 is now active

Ima Link Status Change Up Syslog

ATM_AIM-5-ACTIVE_LINK_CHANGE

Active links were added to or removed from the group, changing the bandwidth of the group

%ATM_AIM-5-ACTIVE_LINK_CHANGE : IMA Group ATM3/1/ima0 now has 2 active links

IMA Active Link Change Syslog

CDP-4-NATIVE_VLAN_MISMATCH

Native VLAN mismatch discovered

%CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on GigabitEthernet1/1 (12), with 3750E-24TD-AGG3 FastEthernet0/2 (1)

Native VLAN mismatch discovered

TOP_MODULE-6-CLK_STATUS_CHANGE

Clock status change

Mar 19 15:26:54.371: %TOP_MODULE-6-CLK_STATUS_CHANGE: PLL clock changed to LOCKED

Clock status change syslog

TOP_MODULE-6-CLK_SOURCE_CHANGE

Clock source change

Mar 19 15:15:40.523: %TOP_MODULE-6-CLK_SOURCE_CHANGE: Changing clock reference source to Seconary TDM 8KHZ

Clock source change syslog

L2-L2VPN_PW-3-UPDOWN

The L2VPN Pseudowire went down

%L2-L2VPN_PW-3-UPDOWN : Pseudowire with address 2.2.2.2, id 140, state is Down

pseudo wire tunnel down syslog

L2-L2VPN_PW-3-UPDOWN

The L2VPN Pseudowire went up

%L2-L2VPN_PW-3-UPDOWN : Pseudowire with address 2.2.2.2, id 140, state is Up

pseudo wire tunnel up syslog

ETHER_SERVICE-6-ERR_DISABLED

Service instance shutdown due to errdisable.

%ETHER_SERVICE-6-ERR_DISABLED: Mac security violation - shutdown service instance 900 on interface GigabitEthernet10/0/12

EFP service error disabled syslog

ETHER_SERVICE-6-UPDOWN

Service instance shutdown Syslog

%ETHER_SERVICE-6-UPDOWN: Service instance 111 on interface GigabitEthernet10/0/3 changed to down

EFP down syslog

ETHER_SERVICE-6-UPDOWN

Service instance up Syslog

%ETHER_SERVICE-6-UPDOWN: Service instance 111 on interface GigabitEthernet10/0/3 changed to up

EFP up syslog

REP-SP-4-LINKSTATUS

The Resilient Ethernet Protocol (REP) link status has changed.

<188>950: *Aug 28 05:07:26.987: %REP-SP-4-LINKSTATUS: GigabitEthernet5/11 (segment 1) is non-operational due to neighbor not responding 

REP link not operational syslog

REP-SP-4-LINKSTATUS

The Resilient Ethernet Protocol (REP) link status has changed.

<188>949:*Aug 28 05:04:40.690: %REP-SP-4-LINKSTATUS: GigabitEthernet5/11 (segment 1) is operational 

REP link operational syslog

OSPFv3-5-ADJCHG

An OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from FULL to DOWN, Neighbor Down: Interface down or detached

OSPFv3 neighbor down syslog

OSPFv3-5-ADJCHG

An OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from LOADING to FULL, Neighbor Down: Interface down or detached

OSPFv3 neighbor up syslog

ETHER_CFM-6-ENTER_AIS

handle CFM AIS defect syslog

%ETHER_CFM-6-ENTER_AIS: local mep with mpid 101 level 4 id 7 dir I Interface Ethernet0/0 enters AIS defect condition

CFM enter AIS defect syslog

ETHER_CFM-6-EXIT_AIS

handle CFM AIS defect syslog

%ETHER_CFM-6-EXIT_AIS: local mep with mpid 101 level 4 id 7 dir I Interface Ethernet0/0 enters AIS defect condition

CFM exit AIS defect syslog

E_CFM-6-ENTER_AIS

handle CFM AIS defect syslog

%E_CFM-6-ENTER_AIS: local mep with mpid 7606 level 4 BD/VLAN 22 dir D Interface Gi5/1 enters AIS defect condition

CFM enter AIS defect syslog

E_CFM-6-EXIT_AIS

handle CFM AIS defect syslog

%E_CFM-6-EXIT_AIS: local mep with mpid 7606 level 4 BD/VLAN 22 dir D Interface Gi5/1 enters AIS defect condition

CFM exit AIS defect syslog

ETHER_CFM-6-ENTER_AIS_INT

handle CFM interface AIS defect syslog

%ETHER_CFM-6-ENTER_AIS_INT: Interface Ethernet0/0 enters AIS defect condition for outward direction

CFM interface enter AIS defect syslog

ETHER_CFM-6-EXIT_AIS_INT

handle CFM interface AIS defect syslog

%ETHER_CFM-6-EXIT_AIS_INT: Interface Ethernet0/0 enters AIS defect condition for outward direction

CFM interface exit AIS defect syslog

E_CFM-6-ENTER_AIS_INT

handle CFM interface AIS defect syslog

%E_CFM-6-ENTER_AIS_INT: Interface GigabitEthernet5/1 enters AIS defect condition for Down direction

CFM interface enter AIS defect syslog

E_CFM-6-EXIT_AIS_INT

handle CFM interface AIS defect syslog

%E_CFM-6-EXIT_AIS_INT: Interface GigabitEthernet5/1 enters AIS defect condition for Down direction

CFM interface exit AIS defect syslog

E_CFM-6-ENTER_LCK

handle CFM AIS defect syslog

%E_CFM-6-ENTER_LCK: local mep with mpid 7606 level 4 BD/VLAN 22 dir D Interface Gi5/1 enters LCK defect condition

CFM enter LCK defect syslog

E_CFM-6-EXIT_LCK

handle CFM AIS defect syslog

%E_CFM-6-EXIT_LCK: local mep with mpid 7606 level 4 BD/VLAN 22 dir D Interface Gi5/1 exited LCK defect condition

CFM exit LCK defect syslog

E_CFM-6-ENTER_LCK_INT

CFM interface enter LCK defect syslog

%E_CFM-6-ENTER_LCK_INT: Interface GigabitEthernet5/1 enters LCK defect condition for Down direction

CFM interface enter LCK syslog

E_CFM-6-EXIT_LCK_INT

CFM interface exit LCK defect syslog

%E_CFM-6-EXIT_LCK_INT: Interface GigabitEthernet5/1 exited LCK defect condition for Down direction

CFM interface exit LCK syslog

E_CFM-3-REMOTE_MEP_DOWN

handle Remote MEP syslog

%E_CFM-3-REMOTE_MEP_DOWN: Remote MEP mpid 1911 evc DemoAugEVC vlan 911 MA name DemoAugMA in domain DemoAugDA changed state to down with event code TimeOut.

CFM Mep Down syslog

E_CFM-3-REMOTE_MEP_UP

handle Remote MEP syslog

%E_CFM-6-REMOTE_MEP_UP: Continuity Check message is received from a remote MEP with mpid 755 evc EVC_S4_22 vlan 22 MA name S4_22 domain L4 interface status Up event code Returning.

CFM Mep Up syslog

ETHER_CFM-3-REMOTE_MEP_DOWN

handle Remote MEP syslog

%ETHER_CFM-3-REMOTE_MEP_DOWN: Remote MEP mpid 537 vlan 555 CSIID S4_sw in domain D4_sw changed state to down with event code lastGasp.

CFM Mep Down syslog

ETHER_CFM-3-REMOTE_MEP_UP

handle Remote MEP syslog

%ETHER_CFM-3-REMOTE_MEP_UP: Remote MEP mpid 537 vlan 555 CSIID S4_sw in domain D4_sw changed state to up with event code lastGasp.

CFM Mep Up syslog

E_CFM-6-REMOTE_MEP_DOWN

handle Remote MEP syslog

%E_CFM-6-REMOTE_MEP_DOWN: Continuity Check message is received from a remote MEP with mpid 755 evc EVC_S4_22 vlan 22 MA name S4_22 domain L4 interface status Down event code Returning.

CFM Mep Down syslog

E_CFM-6-REMOTE_MEP_UP

handle Remote MEP syslog

%E_CFM-6-REMOTE_MEP_UP: Continuity Check message is received from a remote MEP with mpid 755 evc EVC_S4_22 vlan 22 MA name S4_22 domain L4 interface status Up event code Returning.

CFM Mep Up syslog

OSPFv3-5-ADJCHG

An OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from FULL to DOWN, Neighbor Down: Interface down or detached

OSPFv3 neighbor down syslog

OSPFv3-5-ADJCHG

An OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from LOADING to FULL, Neighbor Down: Interface down or detached

OSPFv3 neighbor up syslog

TOP_MODULE-5-APPL_UPDOWN

Timing over packet application syslog

%TOP_MODULE-5-APPL_UPDOWN: Timing over packet application is down

Timing over packet application down syslog

TOP_MODULE-5-APPL_UPDOWN

Timing over packet application syslog

%TOP_MODULE-5-APPL_UPDOWN: Timing over packet application is up

Timing over packet application up syslog

HSRP-5-STATECHANGE

handle hsrp 5 syslog

%HSRP-5-STATECHANGE: GigabitEthernet0/1.555 Grp 55 state Active -> Init

HSRP group change syslog

HSRP-5-STATECHANGE

handle hsrp 5 syslog

%HSRP-5-STATECHANGE: GigabitEthernet0/1.555 Grp 55 state Active -> Standby

HSRP group restored syslog

DWDM-4-G709ALARM

The specified G709 Alarm has been declared

%DWDM-4-G709ALARM : DWDM 2/0/0 : LOS declared

Layer2 G709 alarm syslog

DWDM-4-G709ALARM

The specified G709 Alarm has been cleared

%DWDM-4-G709ALARM : DWDM 2/0/0 : LOS cleared

Layer2 G709 clear syslog


Cisco IOX Syslogs

Table 37-3 lists the Cisco IOX Syslogs supported in Cisco ANA.

Table 37-3 Cisco IOX Syslogs 

Syslog Name
Description
Raw Format
Short Description

LINK-3-UPDOWN

The interface hardware has gone either down or up.

%LINK-3-UPDOWN: Interface ATM2/0, changed state to down

Link down syslog

LINK-3-UPDOWN

The interface hardware has gone either down or up.

%LINK-3-UPDOWN: Interface ATM2/0, changed state to up

Link up syslog

LINK-5-CHANGED

The interface has changed state.

%LINK-5-CHANGED: Interface Ethernet5/1, changed state to administratively up

Link down syslog

LINK-5-CHANGED

The interface has changed state.

%LINK-5-CHANGED: Interface Ethernet5/1, changed state to administratively down

Link up syslog

LINEPROTO-5-UPDOWN

The data link level line protocol changed state.

%LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed state to up

Line down syslog

LINEPROTO-5-UPDOWN

The data link level line protocol changed state.

%LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed state to up

Line up syslog

OSPF-5-ADJCHG

An OSPF neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPF-5-ADJCHG: Process 1, Nbr 192.168.100.100 on POS1/0 from FULL to DOWN, Neighbor Down: Interface down or detached

OSPF neighbor down syslog

OSPF-5-ADJCHG

An OSPF neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPF-5-ADJCHG: Process 1, Nbr 192.168.100.100 on POS1/0 from FULL to DOWN, Neighbor Down: Interface down or detached

OSPF neighbor up syslog

ENVMON-ADDITIVE-POWER-OVERBUDGET

The power calculated in use by the chassis exceeds that available by the powershelf.
This condition could result in an outage of the chassis if action is not immediately taken

PLATFORM-ENVMON-2-POWERSUPPLY_CURRENT : 1 current has reached high level at 1 A

envmon powersupply syslog

ENVMON-ENV-CONDITION

One or more environmental conditions exist on the specified slot. If left untended, they could result in loss of service or even hardware damage

PLATFORM-ENVMON-2-ENV_CONDITION : An environmental condition exists on slot 1

envmon condition syslog

ENVMON-ENV-CONDITION

One or more environmental conditions exist on the specified slot. If left untended, they could result in loss of service or even hardware damage

PLATFORM-ENVMON-2-ENV_CONDITION_CLEAR : The environmental condition on slot 1 has cleared

envmon condition clear syslog

ENVMON-FAN

The fan array specified has reached a warning or critical level and is approaching or approached a condition that is outside the acceptable range

PLATFORM-ENVMON-2-FAN : The fan array 1 has reached high level.

envmon fan syslog

ENVMON-FAN

The fan array specified has reached a warning or critical level and is approaching or approached a condition that is outside the acceptable range

PLATFORM-ENVMON-2-FAN_CLEAR : The fan array 1 has reached high level.

envmon fan clear syslog

ENVMON-LOW-FAN-SPEED-WARNING

Indicates that the fan is spinning very slow

PLATFORM-ENVMON-5-LOW_FAN_SPEED_WARNING : 1 is spinning slow - speed is dRPM (register value = 0x x)

envmon fan syslog

ENVMON-OVERTEMP

The temperature sensor specified has reached a warning or critical level and is approaching or approached a condition that is outside the acceptable range

PLATFORM-ENVMON-2-OVERTEMP : 1 temperature has reached high level

envmon tempretaure syslog

ENVMON-OVERTEMP

The temperature sensor specified has reached a warning or critical level and is approaching or approached a condition that is outside the acceptable range

PLATFORM-ENVMON-2-OVERTEMP_CLEAR : 1 temperature has returned to a normal level

envmon tempretaure clear syslog

ENVMON-PEM-REMOVE

The power entry module specified was detected as removed

PLATFORM-ENVMON-5-PEM_REMOVE : 2 removed from slot 2

card out syslog

ENVMON-PEM-REMOVE

The power entry module specified was detected as removed

PLATFORM-ENVMON-5-PEM_INSERT : 2 inserted into slot 2

card in syslog

ENVMON-POWERSUPPLY-CURRENT

handle envmon powersupply current syslog

PLATFORM-ENVMON-2-POWERSUPPLY_CURRENT : 1 current has reached high level at 1 A

envmon powersupply syslog

ENVMON-POWERSUPPLY-CURRENT

The current supply specified has reached a critical level and is now out of specification

PLATFORM-ENVMON-2-POWERSUPPLY_CURRENT_CLEAR : 1 current has returned to a normal level at d

envmon powersupply clear syslog

ENVMON-POWERSUPPLY-NONOP

The power supply specified has become non operational

PLATFORM-ENVMON-2-POWERSUPPLY_NONOP : Powersupply1 is Non-Operational

envmon powersupply syslog

ENVMON-POWERSUPPLY-NONOP

The power supply specified has become non operational

PLATFORM-ENVMON-2-POWERSUPPLY_NONOP_CLEAR : Powersupply1 has become operational

envmon powersupply clear syslog

ENVMON-POWERSUPPLY-VOLTAGE

The voltage supply specified has reached a critical level and is now out of specification

PLATFORM-ENVMON-2-POWERSUPPLY_VOLTAGE : Powersupply1 voltage has reached high level at 11 V

envmon powersupply syslog

ENVMON-POWERSUPPLY-VOLTAGE

The voltage supply specified has reached a critical level and is now out of specification

PLATFORM-ENVMON-2-POWERSUPPLY_VOLTAGE_CLEAR : Powersupply1 voltage has returned to a normal level at d V

envmon powersupply clear syslog

ENVMON-TEMP

The temperature sensor specified has reached a warning or critical level and is approaching or approached a condition that is outside the acceptable range

PLATFORM-ENVMON-2-OVERTEMP : 1 temperature has reached high level

envmon tempretaure syslog

ENVMON-TEMP

The temperature sensor specified has reached a warning or critical level and is approaching or approached a condition that is outside the acceptable range

PLATFORM-ENVMON-2-OVERTEMP_CLEAR : 1 temperature has returned to a normal level

envmon tempretaure clear syslog

ENVMON-VOLTAGE

The voltage supply specified has reached a critical level and is now out of specification

PLATFORM-ENVMON-2-POWERSUPPLY_VOLTAGE : Powersupply1 voltage has reached high level at 11 V

envmon powersupply syslog

ENVMON-VOLTAGE

The voltage supply specified has reached a critical level and is now out of specification

PLATFORM-ENVMON-2-POWERSUPPLY_VOLTAGE_CLEAR : Powersupply1 voltage has returned to a normal level at d V

envmon powersupply clear syslog

FIA-FIAHW-LOS

This error indicates a problem (Loss of Sync) in the interface between the card reporting error and the switch fabric card in the indicated slot. This error is traffic affecting. Error recovery is triggered by this error

ENVMON-3-FIAHW_LOS : Persistent LOS on serial link (from slot 2)

fabric hardware syslog

FIA-FIAHW-LOS

This error indicates a problem (Loss of Sync) in the interface between the card reporting error and the switch fabric card in the indicated slot. This error is traffic affecting. Error recovery is triggered by this error

ENVMON-3-FIAHW_LOS_CLEAR LOS : cleared on serial link (from slot 2)

fabric hardware clear syslog

FLASH-CARD-REMOVAL

handle flash card insertion or removal syslog

libpcmcia_ide-1-CARD_UNAVAILABLE : flash1: Can not access flash device

flash card removed syslog

FLASH-CARD-REMOVAL

handle flash card insertion or removal syslog

libpcmcia_ide-1-CARD_SWAPPED : flash1: The flash card has been swapped (OIR)

flash card inserted syslog

LIBPARSER-ERR-MEMALLOC

handle memory allocation in syslog

MGBL-LIBPARSER-3-ERR_MEM_ALLOC : s: memory allocation routine failed.

Memory allocation is not available

NODE-RELOAD

handle node reload syslog by sysldr

PLATFORM-SHELFMGR-3-SHUTDOWN_RESET : Node 0/SM2/* is reset due to admin shut shut request

Module reset syslog

NODE-STATE-CHANGE

Indicates a change in the card oper status

PLATFORM-INVMGR-6-NODE_STATE_CHANGE : Node: 0/RP0/*, state: BRINGDOWN

Card oper status changed

NODE-STATE-CHANGE

Indicates a change in the card oper status

PLATFORM-INVMGR-6-NODE_STATE_CHANGE : Node: 0/0/CPU0, state: IOS XR RUN

Card oper status changed

OIROUT

handle module out syslog

%PLATFORM-INV-6-OIROUT : OIR: Node 0/0/CPU0 removed

card out syslog

OIROUT

handle module out syslog

%PLATFORM-INV-6-OIRIN : OIR: Node 0/0/CPU0 inserted

card in syslog

OIROUT-on-CPU0

handle module out syslog

%PLATFORM-INV-6-OIROUT : OIR: Node 0/0/CPU0 removed

card out syslog

OIROUT-on-CPU0

handle module out syslog

%PLATFORM-INV-6-OIRIN : OIR: Node 0/0/CPU0 inserted

card in syslog

PIM-5-NBRCHG

handle pim neighbor syslog

PIM-5-NBRCHG: neighbor 172.72.73.1 DOWN on MgmtEth0/RSP0/CPU0/1

pim neighbor loss syslog

PIM-5-NBRCHG

handle pim neighbor syslog

PIM-5-NBRCHG: neighbor 192.168.2.1 UP on MgmtEth0/RSP0/CPU0/1

pim neighbor up syslog

PIM-5-UPDOWN

handle pim interface syslog

ROUTING-IPV4_PIM-5-INTCHG : PIM interface GigabitEthernet0/3/0/0 DOWN

pim interface down syslog

PIM-5-UPDOWN

handle pim interface syslog

ROUTING-IPV4_PIM-5-INTCHG : PIM interface GigabitEthernet0/3/0/0 UP

pim interface up syslog

PIM-INVALID-JOIN

handle pim invlid join in syslog

ROUTING-IPV4_PIM-5-INVALID_JP : PIM invalid POS0/2/0/0 J/P message from POS0/2/0/0 with RP address 1.1.1.1

pim invalid join syslog

POWERDOWN-RESET

Indicates that the node will be reset because the user has administratively `power disable' or `no power disable' the node

PLATFORM-SHELFMGR-3-POWERDOWN_RESET : Node 0/0/CPU0 is powered off due to admin power off request

Card oper status changed

POWERDOWN-RESET

Indicates that the node will be reset because the user has administratively `power disable' or `no power disable' the node

PLATFORM-SHELFMGR-3-POWERDOWN_RESET : Node 0/0/CPU0 is powered on due to admin power on request

Card oper status changed

SONET-LOCAL-4-ALARM

The specified SONET Alarm has been declared or released

SONET_LOCAL-4-ALARM : Interface SONET/2/0/0: changed SLOS

Line down syslog

SONET-LOCAL-4-ALARM

The specified SONET Alarm has been declared or released

SONET_LOCAL-4-ALARM : Interface SONET/2/0/0: changed SLOS cleared

Line up syslog

SPA-OIROUT

handle invmgr node state change syslog

<SourceID>LC/0/0/CPU0</SourceID> L2-SPA-5-OIR_REMOVED : SPA removed from bay 0

card out syslog

SPA-OIROUT

handle invmgr node state change syslog

<SourceID>LC/0/0/CPU0</SourceID> L2-SPA-5-OIR_INSERTED : SPA discovered in bay 0

card in syslog

ROUTING-LDP-5-NBR_CHANGE

A LDP neighbor has changed state (up/down). If neighbor has went down, then a reason for session going down is also displayed. This message appears only if the log neighbor command is configured for the LDP process.

ROUTING-LDP-5-NBR_CHANGE : Neighbor 7.7.7.7:0, DOWN

LDP neighbor down syslog

ROUTING-LDP-5-NBR_CHANGE

A LDP neighbor has changed state (up/down). If neighbor has went down, then a reason for session going down is also displayed. This message appears only if the log neighbor command is configured for the LDP process.

gRP/0/RP0/CPU0:Sep 25 14:22:35.329 : mpls_ldp[274]: ROUTING-LDP-5-NBR_CHANGE : Neighbor 7.7.7.7:0, UP

LDP neighbor up syslog

BGP-5-ADJCHANGE

The adjacent BGP neighbor was lost

BGP-5-ADJCHANGE : neighbor 172.23.95.15 Down - BGP Notification received: configuration change

BGP neighbor down syslog

BGP-5-ADJCHANGE

The adjacent BGP neighbor was lost

BGP-5-ADJCHANGE : neighbor 172.23.95.15 Up - BGP Notification received: configuration change

BGP neighbor up syslog

SECURITY-4-AUTHEN_FAILED

The user login authentication failed

SECURITY-login-4-AUTHEN_FAILED. : Failed authentication attempt by user 'user_A' from '161.44.192.231'

Login authentication failed syslog

MGBL-INVENTORY-6-PORTS

Sent by the XR device after a card-in event has occured and the If and Entity tables are in sync. Once Cisco ANA receives the syslog, it will expedite the physical command instead of the card-in syslogs doing the expedite, so that the polling is done only after the tables are synchronized.

%MGBL-INVENTORY-6-PORTS : ifTable INSYNC for card:0/PL7/* entPhysicalIndex:239

If-Table in sync syslog

L2-BFD-6-SESSION_STATE_DOWN

The bfd session is down

%L2-BFD-6-SESSION_STATE_DOWN : BFD session to neighbor 23.1.1.1 on interface GigabitEthernet0/2/0/0 has gone down. Reason: Echo function failed

bfd session down syslog

L2-BFD-6-SESSION_REMOVED

The bfd session has been removed

%L2-BFD-6-SESSION_REMOVED : BFD session to neighbor 23.1.1.1 on interface GigabitEthernet0/2/0/0 has gone down. Reason: Echo function failed

bfd session removed syslog

L2-BFD-6-SESSION_STATE_UP

The bfd session is up

%L2-BFD-6-SESSION_STATE_UP : BFD session to neighbor 23.1.1.1 on interface GigabitEthernet0/2/0/0 has gone down. Reason: Echo function failed

bfd session up syslog

L2-G709-4-ALARM

The specified G709 Alarm has been declared or released

LC/0/0/CPU0:Feb 16 05:36:25.553 : plim_4p_10ge_dwdm[204]: %L2-G709-4-ALARM : DWDM0/0/0/0: LOS

Layer2 G709 alarm syslog

L2-G709-4-ALARM-CLEARED

The specified G709 Alarm has been declared or released

LC/0/0/CPU0:Feb 16 05:36:25.553 : plim_4p_10ge_dwdm[204]: %L2-G709-4-ALARM : DWDM0/0/0/0: LOS cleared

Layer2 G709 clear syslog

L2-DWDM-3-INFO

The DWDM encountered an error that would lead to degraded service

LC/0/0/CPU0:Feb 16 05:36:25.553 : plim_4p_10ge_dwdm[204]: %L2-DWDM-3-INFO dwdm: service degrading error, reason equals ERROR

Layer2 dwdm info syslog

L1-PMENGINE-4-TCA

The specified PM TCA has been declared

%L1-PMENGINE-4-TCA Port [chars] reports [chars] [chars]([chars]) PM TCA with current value [unsigned long long int], threshold [unsigned long long int] in current [chars] interval window

Layer1 PM TCA syslog

L2-SPA-3-POWER_FAILURE

SPA_OK and PWR_OK signals are asserted after the SPA is powered on by LC. These signals are deasserted when there is a power failure on the SPA and this failure indicates that it is an SPA hardware issue. The SPA is put into FAILED state.

%L2-SPA-3-POWER_FAILURE SPA_OK and PWR_OK signal is deasserted on subslot [unsigned int]

Layer2 SPA failure syslog

ROUTING-OSPF-5-ADJCHG

An OSPF routing neighbor has changed state. The message describes the change and the reason for it.

%ROUTING-OSPF-5-ADJCHG : Process 1, Nbr 2.2.2.2 on MgmtEth0/7/CPU0/2 in area 0 from FULL to DOWN, Loading Done,vrf default vrfid 0x60000000

OSPF routing neighbor down syslog

ROUTING-OSPF-5-ADJCHG

An OSPF routing neighbor has changed state. The message describes the change and the reason for it.

%ROUTING-OSPF-5-ADJCHG : Process 1, Nbr 2.2.2.2 on MgmtEth0/7/CPU0/2 in area 0 from LOADING to FULL, Loading Done,vrf default vrfid 0x60000000

OSPF routing neighbor up syslog

OSPFv3-5-ADJCHG-IPv6

An IPv6 OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from FULL to DOWN, Neighbor Down: Interface down or detached

OSPFv3 neighbor down syslog

OSPFv3-5-ADJCHG-IPv6

An IPv6 OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from LOADING to FULL, Neighbor Down: Interface down or detached

OSPFv3 neighbor up syslog

ROUTING-OSPFv3-5-ADJCHG

An IPv6 OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%ROUTING-OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from FULL to DOWN, Neighbor Down: Interface down or detached

OSPFv3 routing neighbor down syslog

ROUTING-OSPFv3-5-ADJCHG

An IPv6 OSPFv3 neighbor has changed state. The message describes the change and the reason for it. This message appears only if the log-adjacency-changes command is configured for the OSPF process.

%ROUTING-OSPFv3-5-ADJCHG : Process 1, Nbr 192.168.1.1 on Mg0/5/CPU0/1 from LOADING to FULL, Neighbor Down: Interface down or detached

OSPFv3 routing neighbor up syslog

BGP-5-ADJCHANGE-IPv6

The IPv6 adjacent BGP neighbor was lost

%ROUTING-BGP-5-ADJCHANGE : neighbor 3.3.3.3 down (VRF: default) %ROUTING-BGP-5-ADJCHANGE : neighbor 2001:210:10:1::1 Down - User clear requested

Routing BGP neighbor down syslog

BGP-5-ADJCHANGE-IPv6

The IPv6 adjacent BGP neighbor was lost

%ROUTING-BGP-5-ADJCHANGE : neighbor 3.3.3.3 Up (VRF: default) %ROUTING-BGP-5-ADJCHANGE : neighbor 2001:210:10:1::1 Up

Routing BGP neighbor up syslog

ROUTING-BGP-5-ADJCHANGE

The IPv6 adjacent BGP neighbor was lost

%ROUTING-BGP-5-ADJCHANGE : neighbor 3.3.3.3 down (VRF: default) %ROUTING-BGP-5-ADJCHANGE : neighbor 2001:210:10:1::1 Down - User clear requested

IPv6 Routing BGP neighbor down syslog

ROUTING-BGP-5-ADJCHANGE

The IPv6 adjacent BGP neighbor was lost

%ROUTING-BGP-5-ADJCHANGE : neighbor 3.3.3.3 Up (VRF: default) %ROUTING-BGP-5-ADJCHANGE : neighbor 2001:210:10:1::1 Up

IPv6 Routing BGP neighbor up syslog

L2-L2VPN_PW-3-UPDOWN

The L2VPN Pseudowire went down

%L2-L2VPN_PW-3-UPDOWN : Pseudowire with address 2.2.2.2, id 140, state is Down

pseudo wire tunnel down syslog

L2-L2VPN_PW-3-UPDOWN

The L2VPN Pseudowire went up

%L2-L2VPN_PW-3-UPDOWN : Pseudowire with address 2.2.2.2, id 140, state is Up

pseudo wire tunnel up syslog

ETHER_SERVICE-6-ERR_DISABLED

Service instance shutdown due to errdisable.

%ETHER_SERVICE-6-ERR_DISABLED: Mac security violation - shutdown service instance 900 on interface GigabitEthernet10/0/12

EFP service error disabled syslog

L2-DWDM-3-NOT_YET_IMPLEMENTED

handle L2-DWDM-3-NOT_YET_IMPLEMENTED syslog

%L2-DWDM-3-NOT_YET_IMPLEMENTED dwdm: this function [chars] is not yet implemented

DWDM feature not implemented yet

L2-DWDM-3-FATAL_2

handle L2-DWDM-3-FATAL_2 syslog

%L2-DWDM-3-FATAL_2 dwdm: fatal error encountered, reason equals [chars], errno equals 1

DWDM fatal error with reason and error number

L2-DWDM-3-FATAL

handle L2-DWDM-3-FATAL syslog

%L2-DWDM-3-FATAL dwdm: fatal error encountered, reason equals 1

DWDM fatal error with reason

L2-PLIM-2-EIO_TRAIN

handle L2-PLIM-2-EIO_TRAIN syslog

%L2-PLIM-2-EIO_TRAIN PLA: [chars], [chars]

PLIM EIO training errors syslog

L2-PLIM-3-CHK_ERR

handle L2-PLIM-3-CHK_ERR syslog

%L2-PLIM-3-CHK_ERR PLA: [chars], [chars]

PLIM Checkpoint Initialization Failure syslog

L2-PLIM-3-HW_ERR

handle L2-PLIM-3-HW_ERR syslog

%L2-PLIM-3-HW_ERR asic error: [chars]

PLIM ASIC error syslog

L2-PLIM-3-MEM_ERR

handle L2-PLIM-3-MEM_ERR syslog

%L2-PLIM-3-MEM_ERR [chars]

PLIM memory error syslog

L2-PLIM-3-SQUID_ERR

handle L2-PLIM-3-SQUID_ERR syslog

%L2-PLIM-3-SQUID_ERR [chars]

PLIM squid error syslog

L2-PLIM-7-ERR

handle L2-PLIM-7-ERR syslog

%L2-PLIM-7-ERR [chars]

PLIM 7 error syslog

L2-PLIM_OC768-3-CRITICAL_ERROR

handle L2-PLIM_OC768-3-CRITICAL_ERROR syslog

%L2-PLIM_OC768-3-CRITICAL_ERROR [chars]: [chars]: [hex]

PLIM OC768 critical error syslog

L2-PLIM_OC768-6-INFO

handle L2-PLIM_OC768-6-INFO syslog

%L2-PLIM_OC768-6-INFO [chars]: [chars]

PLIM OC768 INFO syslog

L2-PLIM_OC768-7-DEBUG_MSG

handle L2-PLIM_OC768-7-DEBUG_MSG syslog

%L2-PLIM_OC768-7-DEBUG_MSG Debug: [chars]: [chars] errno 1

PLIM OC768 debug syslog

BGP-3-NOTIFICATION

handle BGP 3 syslog

%BGP-3-NOTIFICATION: sent to neighbor 10.10.10.254 4/0 (hold time expired) 0 bytes

BGP notification syslog

BGP-3-NOTIFICATION

handle BGP 3 syslog

%BGP-3-NOTIFICATION: sent to neighbor 10.10.10.254 4/0 (hold time expired) 0 bytes

BGP notification syslog


Cisco ASR 9000 Syslog Registry Parameters

Table 37-4 lists the associated event types, event subtypes, and Cisco ANA registry parameters for the Cisco ASR syslogs shown in Table 37-1.

Table 37-4 Cisco ASR Syslog Registry Parameters  

Short
Description
Event Type
Event
Subtype
Subtype
Value
Expedites
Polling
Event Source
(IMO Name)
Activate
Flow
Correlate
Is Correlation
Allowed
Weight
Auto Clear
Severity
Is Ticketable
Auto
Remove
Flapping

Power supply inserted syslog

power supply removed syslog

power supply inserted syslog

inserted

N

IModule

F

F

F

0

F

clr

F

T

F

Power supply removed syslog

power supply removed syslog

power supply removed syslog

removed

N

IModule

F

F

F

0

F

maj

T

T

F

Backup to Master change syslog

Backup to Master syslog

Backup to Master syslog

Backup

N

IIPInterface

F

F

F

0

F

info

T

T

F

Master to Backup change syslog

Backup to Master syslog

Master to Backup syslog

Master

N

IIPInterface

F

F

F

0

F

info

T

T

F

BFD rate limit high warning syslog

bfd rate limit high warning syslog

bfd rate limit high warning syslog

N/A

N

IBfdService

F

F

F

0

T

wrn

F

T

F

RIP authentication failed syslog

rip authentication failed syslog

rip authentication failed syslog

N/A

N

IIPInterface

F

F

F

0

T

min

F

T

F

RIP configuration error syslog

rip configuration error syslog

rip configuration error syslog

N/A

N

IManagedElement

F

F

F

0

T

min

F

T

F

RIP out of memory event syslog

rip out of memory event syslog

rip out of memory event syslog

N/A

N

IManagedElement

F

F

F

0

F

info

F

T

F

routing ISIS neighbor down syslog

routing isis neighbor down syslog

routing isis neighbor down syslog

down

N

IPhysicalLayer

F

T

F

0

F

maj

F

T

F

routing ISIS neighbor up syslog

routing isis neighbor down syslog

routing isis neighbor up syslog

up

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F


Cisco IOS Syslog Registry Parameters

Table 37-5 lists the associated event types, event subtypes, and Cisco ANA registry parameters for the Cisco IOS syslogs shown in Table 37-2.

Table 37-5 Cisco IOS Registry Parameters  

Short
Description
Event Type
Event
Subtype
Subtype
Value
Expedites
Polling
Event Source
(IMO Name)
Activate Flow
Correlate
Is Correlation
Allowed
Weight
Auto Clear
Severity
Is Ticketable
Auto Remove
Flapping

Link down syslog

link down syslog

link down syslog

 

mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bun \dle-status/mpls traffic engineering tunnel information/ip interface oper status

IIPInterface

F

T

F

0

T

maj

F

T

T

Link up syslog

link down syslog

link up syslog

 

mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bun \dle-status/mpls traffic engineering tunnel information/ip interface oper status

IIPInterface

F

F

F

0

F

clr

F

T

T

FR DLCI down syslog

dlci change syslog

dlci down

 

N

IPhysicalLayer

T

T

F

0

T

maj

F

T

F

FR DLCI up syslog

dlci change syslog

dlci up

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

HSRP group change syslog

hsrp syslog

hsrp group change syslog

 

hsrp

IIPInterface

F

T

F

0

F

info

F

T

F

HSRP group restored syslog

hsrp syslog

hsrp group restored syslog

 

hsrp

IIPInterface

F

F

F

0

F

clr

F

T

F

SNMP message has not properly authenticated

snmp 5 snmp auth fail syslog

snmp 5 snmp auth fail syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

Memory allocation is not available

memory allocation syslog

memory allocation syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

process ran too long

process ran too long syslog

process ran too long syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

registered timer is expired

registered timer expired syslog

registered timer expired syslog

 

N

IManagedElement

F

T

F

0

F

min

F

T

F

EIGRP router query to neighbors timeouted syslog

EIGRP router query to neighbors timeouted syslog

EIGRP router query to neighbors timeouted syslog

 

N

IManagedElement

T

T

F

0

F

info

F

T

F

Ethernet cable is not connected

ethernet cable is not connected syslog

ethernet cable is not connected syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

frame with an invalid control code

frmr report syslog

frmr report syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Interface changed to non trunk

dtp 5 non port trunk syslog

dtp 5 non port trunk syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Interface changed to trunk

dtp 5 non port trunk syslog

dtp 5 port trunk syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

Line down syslog

line down syslog

line down syslog

 

basetech-lldp-neighbors-snmp/basetech-cdp-neighbors-snmp/mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bundle-status/mpls trafficengineering tunnel information/port-status/ip interface oper status

IIPInterface

F

T

F

0

T

maj

F

T

T

Line up syslog

line down syslog

line up syslog

 

basetech-lldp-neighbors-snmp/basetech-cdp-neighbors-snmp/mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bundle-status/mpls trafficengineering tunnel information/port-status/ip interface oper status

IIPInterface

F

F

F

0

F

clr

F

T

T

Cannot send incremental SAP update to peer

ipx 3 bad igrp sap syslog

ipx 3 bad igrp sap syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

An Ethernet cable is broken or unterminated

lance 5 coll syslog

lance 5 coll syslog

 

N

IManagedElement

F

T

F

0

F

info

F

T

F

An Ethernet transceiver is unplugged or defective

lance 5 late coll syslog

lance 5 late coll syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

Device configuration changed

sys 5 config i syslog

sys 5 config i syslog

 

N

IManagedElement

F

F

F

0

F

info

F

T

F

AppleTalk invalid network number

at 6 node wrong syslog

at 6 node wrong syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

security port shut down

security 1 port shut down syslog

security 1 port shut down syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

BPDU spanning-tree portfast enabled

span tree 2 rx port fast syslog

span tree 2 rx port fast syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Fault has been detected in a fiber Ethernet port connection

udld 3 disable syslog

udld 3 disable syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Unidirectional link detected

udld 3 disable fail syslog

udld 3 disable fail syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Fault has been detected in a fiber Ethernet connection

udld 4 one way path syslog

udld 4 one way path syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

OSPF neighbor down syslog

ospf neighbor syslog

ospf neighbor down syslog

 

N

IIPInterface

T

T

F

0

F

maj

T

T

F

OSPF neighbor up syslog

ospf neighbor syslog

ospf neighbor up syslog

 

N

IIPInterface

F

F

F

0

F

clr

F

T

F

No BPDUs were received on port

span tree 2 loop guard block syslog

span tree 2 loop guard block syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

BPDUs were received on port

span tree 2 loop guard un block syslog

span tree 2 loop guard un block syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Ethernet is seeing multiple collisions

amdp2 fe 5 coll syslog

amdp2 fe 5 coll syslog

 

N

IPhysicalLayer

F

T

F

0

F

info

F

T

F

Fast Ethernet packet has been dropped

dec 21140-5 coll syslog

dec 21140-5 coll syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

An Ethernet cable is broken

ilacc 5 coll syslog

ilacc 5 coll syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

pquicc 5 coll syslog: An Ethernet cable is broken

pquicc 5 coll syslog

pquicc 5 coll syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

pquicc ether 5 coll syslog: An Ethernet cable is broken

pquicc ether 5 coll syslog

pquicc ether 5 coll syslog

 

N

IManagedElement

F

F

F

0

T

min

F

T

F

Ethernet is detecting multiple collisions

pquicc fe 5 coll syslog

pquicc fe 5 coll syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

quicc ether 5 coll syslog: An Ethernet cable is broken

quicc ether 5 coll syslog

quicc ether 5 coll syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

Late collisions have occurred

amdp2 fe 5 latecoll syslog

amdp2 fe 5 latecoll syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

IS-IS neighbor down syslog

is is neighbor down syslog

is is neighbor down syslog

 

N

IPhysicalLayer

F

T

F

0

F

maj

F

T

F

IS-IS neighbor up syslog

is is neighbor down syslog

is is neighbor up syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

Late collisions have occurred

dec 21140-5 late coll syslog

dec 21140-5 late coll syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

ilacc 5 late coll syslog: Late collisions have occurred

ilacc 5 late coll syslog

ilacc 5 late coll syslog

 

N

IManagedElement

F

F

F

0

T

min

F

T

F

pquicc 5 late coll syslog: Late collisions have occurred

pquicc 5 late coll syslog

pquicc 5 late coll syslog

 

N

IManagedElement

F

F

F

0

T

min

F

T

F

A new network may not have been engineered properly

pquicc ether 5 late coll syslog

pquicc ether 5 late coll syslog

 

N

IManagedElement

F

T

F

0

T

min

F

T

F

pquicc fe 5 late coll syslog: Late collisions have occurred

pquicc fe 5 late coll syslog

pquicc fe 5 late coll syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

quicc ether 5 late coll syslog: Late collisions have occurred

quicc ether 5 late coll syslog

quicc ether 5 late coll syslog

 

N

IManagedElement

F

F

F

0

T

min

F

T

F

Link trap down has occurred

snmp 5 link trap syslog

snmp 5 link trap down syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Link trap up has occurred

snmp 5 link trap syslog

snmp 5 link trap up syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

configured port changed state from learning to forwarding

snmp 5 top trap syslog

snmp 5 top trap syslog

 

N

IManagedElement

F

F

F

0

T

min

F

T

F

DUAL 5 neighbor down syslog

dual5 neighbor change

dual5 neighbor down

 

N

IPhysicalLayer

T

T

F

0

F

maj

F

T

F

DUAL 5 neighbor up syslog

dual5 neighbor change

dual5 neighbor up

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

Link down syslog

link down syslog

link down syslog

 

ce-qinq-status-telnet/mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bundle-status/mpls traffic engineering tunnel information/ipinterface oper status

IIPInterface

F

T

F

0

T

maj

F

T

T

Link up syslog

link down syslog

link up syslog

 

ce-qinq-status-telnet/mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bundle-status/mpls traffic engineering tunnel information/ipinterface oper status

IIPInterface

F

F

F

0

F

clr

F

T

T

BGP neighbor down syslog

bgp neighbor down syslog

bgp neighbor down syslog

 

bgp neighbours

IMpBgpOid

F

T

F

0

T

maj

F

T

F

BGP neighbor up syslog

bgp neighbor down syslog

bgp neighbor up syslog

 

bgp neighbours

IMpBgpOid

F

F

F

0

F

clr

F

T

F

BGP neighbor down syslog

bgp neighbor down syslog

bgp neighbor down syslog

 

bgp neighbours

IMpBgpOid

F

T

F

0

T

maj

F

T

F

BGP neighbor up syslog

bgp neighbor down syslog

bgp neighbor up syslog

 

bgp neighbours

IMpBgpOid

F

F

F

0

F

clr

F

T

F

card in syslog

card out syslog

card in syslog

 

physical-command

IModule

F

F

F

0

F

clr

F

T

T

card out syslog

card out syslog

card out syslog

 

physical-command

IModule

F

T

F

0

T

maj

F

T

T

oir sp 3 power cycle syslog

oir sp 3 power cycle

oir sp 3 power cycle

 

N

IModule

F

F

F

0

F

info

F

T

F

Reloading device syslog

reloading device syslog

reloading device syslog

 

N

IManagedElement

F

F

T

200000

F

info

T

T

T

System restart

system restart syslog

system restart syslog

 

physical-command

IManagedElement

F

F

F

0

F

info

F

T

T

Interface changed to non trunk

dtp 5 non port trunk syslog

dtp 5 non port trunk syslog

 

N

IPhysicalLayer

F

T

F

0

T

min

F

T

F

Interface changed to trunk

dtp 5 non port trunk syslog

dtp 5 port trunk syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

ISDN connect syslog

isdn 6 connect syslog

isdn 6 connect syslog

 

N

IPhysicalLayer

F

T

F

0

T

maj

F

T

F

ISDN disconnect syslog

isdn 6 connect syslog

isdn 6 disconnect syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

ISDN connect syslog

isdn 6 connect syslog

isdn 6 connect syslog

 

N

IPhysicalLayer

F

T

F

0

T

maj

F

T

F

ISDN disconnect syslog

isdn 6 connect syslog

isdn 6 disconnect syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

Duplex mismatch discovered

duplex mismatch

duplex mismatch

 

N

IPhysicalLayer

F

T

F

0

F

info

F

T

F

ISDN connect syslog

isdn 6 connect syslog

isdn 6 connect syslog

 

N

IPhysicalLayer

F

T

F

0

T

maj

F

T

F

ISDN disconnect syslog

isdn 6 connect syslog

isdn 6 disconnect syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

ISDN connect syslog

isdn 6 connect syslog

isdn 6 connect syslog

 

N

IPhysicalLayer

F

T

F

0

T

maj

F

T

F

ISDN disconnect syslog

isdn 6 connect syslog

isdn 6 disconnect syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

TDP neighbor down syslog

tdp neighbor down syslog

tdp neighbor down syslog

 

label switching table

ILseOid

F

T

F

0

F

maj

F

T

F

TDP neighbor up syslog

tdp neighbor down syslog

tdp neighbor up syslog

 

label switching table

ILseOid

F

F

F

0

F

clr

F

T

F

LDP neighbor down syslog

ldp neighbor down syslog

ldp neighbor down syslog

 

mpls interfaces

ILseOid

F

T

F

0

T

maj

F

T

F

LDP neighbor up syslog

ldp neighbor down syslog

ldp neighbor up syslog

 

mpls interfaces

ILseOid

F

F

F

0

F

clr

F

T

F

MPSL-TE tunnel reoptimized/rerouted syslog

mpls te tunnel reoptimized syslog

mpls te tunnel reoptimized syslog

 

N

IMplsTETunnel

T

T

F

0

F

info

T

T

F

MPLS TE tunnel down syslog

mpls te tunnel down syslog

mpls te tunnel down syslog

 

mpls traffic engineering tunnel information

IMplsTETunnel

F

T

F

0

T

maj

F

T

F

MPLS TE tunnel up syslog

mpls te tunnel down syslog

mpls te tunnel up syslog

 

mpls traffic engineering tunnel information

IMplsTETunnel

F

F

F

0

F

clr

F

T

F

MPLS TE tunnel down syslog

mpls te tunnel down syslog

mpls te tunnel down syslog

 

mpls traffic engineering tunnel information

IMplsTETunnel

F

T

F

0

T

maj

F

T

F

MPLS TE tunnel up syslog

mpls te tunnel down syslog

mpls te tunnel up syslog

 

mpls traffic engineering tunnel information

IMplsTETunnel

F

F

F

0

F

clr

F

T

F

A power supply is not working or has not been turned on

environment monitoring 2 supply syslog

environment monitoring 2 supply

 

N

IManagedElement

F

F

F

0

F

info

F

T

F

System restart

system sp restart syslog

system sp restart syslog

 

N

IManagedElement

F

F

F

0

F

info

F

T

F

Aggressive Mode Failure Detected

udld sp 4 disable syslog

udld sp 4 disable syslog

 

N

IPhysicalLayer

F

T

F

0

F

info

F

T

F

fabric sp 5 clear block down syslog

fabric sp 5 clear block off syslog

fabric sp 5 clear block off syslog

 

N

IPhysicalLayer

F

T

F

0

F

info

F

T

F

fabric sp 5 clear block up syslog

fabric sp 5 clear block off syslog

fabric sp 5 clear block on syslog

 

N

IPhysicalLayer

F

F

F

0

F

info

F

T

F

c6kenv sp 4 fan tray fail syslog

c6kenv sp 4 fan tray fail

c6kenv sp 4 fan tray fail

 

N

IManagedElement

F

F

F

0

F

info

F

T

F

pfredun sp 4 bootstring invalid syslog

pfredun sp 4 bootstring invalid

pfredun sp 4 bootstring invalid

 

N

IManagedElement

F

F

F

0

F

info

F

T

F

Power supply failed syslog

power supply failure syslog

power supply failed syslog

 

N

IPhysicalLayer

F

F

F

0

T

maj

F

T

F

Power supply okay syslog

power supply failure syslog

power supply okay syslog

 

N

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

pm sp stdby 4 err disable syslog

pm sp stdby 4 err disable

pm sp stdby 4 err disable

 

N

IPhysicalLayer

F

F

F

0

F

info

F

T

F

HSRP group change syslog

hsrp syslog

hsrp group change syslog

 

hsrp

IPhysicalLayer

F

T

F

0

F

info

F

T

F

HSRP group restored syslog

hsrp syslog

hsrp group restored syslog

 

hsrp

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

BGP notification syslog

bgp notification syslog

bgp notification syslog

 

N

IPhysicalLayer

T

T

F

0

F

info

F

T

F

new ethernet channel interface for VSL connection

VSL-connection-new-interface-syslog

VSL connection new interface

 

N

IManagedElement

F

F

F

110000

F

info

T

T

F

VSL link up syslog

VSL-link-state-change-syslog

VSL link up syslog

 

N

IManagedElement

F

F

F

110000

F

info

T

T

F

VSL link down syslog

VSL-link-state-change-syslog

VSL link down syslog

 

N

IManagedElement

F

F

F

110000

F

info

T

T

F

VSL link up syslog: active switch is #1

VSL-link-state-change-syslog

VSL link up and switch 1 is active

 

N

IShelf

F

F

F

110000

F

info

T

T

F

VSL link up syslog: active switch is #2

VSL-link-state-change-syslog

VSL link up and switch 2 is active

 

N

IShelf

F

F

F

110000

F

info

T

T

F

role mismatch resolved syslog, sent from active switch #1

VSL-role-mismatch-resolved-syslog

VSL role mismatch resolved sent from active switch 1

 

N

IShelf

F

F

F

110000

F

info

T

T

F

role mismatch resolved syslog, sent from active switch #2

VSL-role-mismatch-resolved-syslog

VSL role mismatch resolved sent from active switch 2

 

N

IShelf

F

F

F

110000

F

info

T

T

F

env sp 4 fan tray fail syslog

env sp 4 fan tray fail

env sp 4 fan tray fail

 

N

IManagedElement

F

F

F

0

F

info

F

T

F

pwr sp 2 power supply fail syslog

pwr sp 2 power supply fail

pwr sp 2 power supply fail

 

N

IManagedElement

F

F

F

0

F

info

T

T

F

BGP neighbor down syslog

bgp neighbor down syslog

bgp neighbor down syslog

 

bgp neighbours, BFD

IMpBgpOid

F

T

F

0

T

maj

F

T

F

BGP neighbor up syslog

bgp neighbor down syslog

bgp neighbor up syslog

 

bgp neighbours, BFD

IMpBgpOid

F

F

F

0

F

clr

F

T

F

VRRP State Changed syslog

vrrp state changed syslog

vrrp state changed syslog

 

N

IManagedElement

F

F

F

0

F

info

T

T

F

Ima Link Status Change Down Syslog

Ima Link Status Change Down Syslog

Ima Link Status Change Down Syslog

   

IPhysicalLayer

F

T

F

0

F

maj

T

T

T

Ima Link Status Change Up Syslog

Ima Link Status Change Down Syslog

Ima Link Status Change Up Syslog

   

IPhysicalLayer

F

F

F

0

F

clr

F

T

T

IMA Active Link Change Syslog

IMA Active Link Change Syslog

IMA Active Link Change Syslog

 

mtop-ima-group-state,port-status

IMAGroupOid

F

F

F

0

F

info

F

T

F

Native VLAN mismatch discovered

native VLAN mismatch

native VLAN mismatch

 

N

IPhysicalLayer

F

T

F

0

F

info

F

T

F

Clock status change syslog

clock status change syslog

clock status change syslog

 

N

defaultClockDC

F

T

F

0

F

info

F

T

F

Clock source change syslog

clock source change syslog

clock source change syslog

 

N

defaultClockDC

F

T

F

0

F

info

F

T

F

pseudo wire tunnel down syslog

pseudo wire tunnel syslog

pseudo wire tunnel down syslog

 

ce-pw-tunnel-status-telnet

PTPLayer2MplsTunnel

F

T

F

0

F

min

T

T

T

pseudo wire tunnel up syslog

pseudo wire tunnel syslog

pseudo wire tunnel up syslog

 

ce-pw-tunnel-status-telnet

PTPLayer2MplsTunnel

F

F

F

0

F

clr

T

T

T

EFP service error disabled syslog

efp service error disabled syslog

efp service error disabled syslog

 

EFP status

IEFP

F

T

F

0

F

info

F

T

F

EFP down syslog

efp down syslog

efp down syslog

 

EFP status

IEFP

F

T

F

0

T

maj

F

T

F

EFP up syslog

efp down syslog

efp up syslog

 

EFP status

IEFP

F

T

F

0

F

clr

F

T

F

REP link not operational syslog

REP link operational status change

REP link not operational

 

Rep status

IREPService

F

T

F

0

T

min

F

T

F

REP link operational syslog

REP link operational status change

REP link operational

 

Rep status

IREPService

F

F

F

0

F

clr

F

T

F

OSPFv3 neighbor down syslog

ospfv3 neighbor syslog

ospfv3 neighbor down syslog

Down / DOWN

N

IManagedElement

T

T

F

0

F

maj

T

T

F

OSPFv3 neighbor up syslog

ospfv3 neighbor syslog

ospfv3 neighbor up syslog

Up / FULL

N

IManagedElement

F

F

F

0

F

clr

F

T

F

CFM enter AIS defect syslog

CFM enter AIS defect syslog

CFM enter AIS defect syslog

ENTER

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM exit AIS defect syslog

CFM enter AIS defect syslog

CFM exit AIS defect syslog

EXIT

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM enter AIS defect syslog

CFM enter AIS defect syslog

CFM enter AIS defect syslog

ENTER

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM exit AIS defect syslog

CFM enter AIS defect syslog

CFM exit AIS defect syslog

EXIT

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM interface enter AIS defect syslog

CFM interface enter AIS syslog

CFM interface enter AIS syslog

ENTER

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM interface exit AIS defect syslog

CFM interface exit AIS syslog

CFM interface exit AIS syslog

EXIT

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM interface enter AIS defect syslog

CFM interface enter AIS syslog

CFM interface enter AIS syslog

ENTER

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM interface exit AIS defect syslog

CFM interface exit AIS syslog

CFM interface exit AIS syslog

EXIT

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM enter LCK defect syslog

CFM enter LCK defect syslog

CFM enter LCK defect syslog

ENTER

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM exit LCK defect syslog

CFM enter LCK defect syslog

CFM exit LCK defect syslog

EXIT

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM interface enter LCK syslog

CFM interface enter LCK defect syslog

CFM interface enter LCK defect syslog

ENTER

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM interface exit LCK syslog

CFM interface enter LCK defect syslog

CFM interface exit LCK defect syslog

EXIT

N

ICfmServiceOid

F

T

F

0

F

info

F

T

F

CFM Mep Down syslog

Mep Down syslog

Mep Down syslog

DOWN

N

ICfmMaintenanceAssociationOid

F

T

F

0

T

minor

F

T

F

CFM Mep Up syslog

Mep Down syslog

Mep Up syslog

UP

N

ICfmMaintenanceAssociationOid

F

F

F

0

F

clr

F

T

F

CFM Mep Down syslog

Mep Down syslog

Mep Down syslog

DOWN

N

ICfmMaintenanceAssociationOid

F

T

F

0

T

minor

F

T

F

CFM Mep Up syslog

Mep Down syslog

Mep Up syslog

UP

N

ICfmMaintenanceAssociationOid

F

F

F

0

F

clr

F

T

F

CFM Mep Down syslog

Mep Down syslog

Mep Down syslog

DOWN

N

ICfmMaintenanceAssociationOid

F

T

F

0

T

minor

F

T

F

CFM Mep Up syslog

Mep Down syslog

Mep Up syslog

UP

N

ICfmMaintenanceAssociationOid

F

F

F

0

F

clr

F

T

F

OSPFv3 neighbor down syslog

ospfv3 neighbor syslog

ospfv3 neighbor down syslog

Down / DOWN

N

IManagedElement

T

T

F

0

F

maj

T

T

F

OSPFv3 neighbor up syslog

ospfv3 neighbor syslog

ospfv3 neighbor up syslog

Up / FULL

N

IManagedElement

F

F

F

0

F

clr

F

T

F

Timing over packet application down syslog

timing over packet application down syslog

timing over packet application down syslog

down

N

IManagedElement

F

F

F

0

F

min

T

T

T

Timing over packet application up syslog

timing over packet application down syslog

timing over packet application up syslog

up

N

IManagedElement

F

F

F

0

F

clr

F

T

T

HSRP group change syslog

hsrp syslog

hsrp group change syslog

 

hsrp

IPhysicalLayer

F

T

F

0

F

info

F

T

F

HSRP group restored syslog

hsrp syslog

hsrp group restored syslog

 

hsrp

IPhysicalLayer

F

F

F

0

F

clr

F

T

F

Layer2 G709 alarm syslog

layer2 G709 alarm syslog

layer2 G709 alarm syslog

declared

N

DWDM Oid

F

F

F

0

T

wrn

F

T

F

Layer2 G709 clear syslog

layer2 G709 alarm syslog

layer2 G709 clear syslog

cleared

N

DWDM Oid

F

F

F

0

F

clr

F

T

F


Cisco IOX Syslog Registry Parameters

Table 37-1 lists the associated event types, event subtypes, and Cisco ANA registry parameters for the Cisco IOX syslogs shown in Table 37-1.

Table 37-6 Cisco IOX Registry Parameters  

Short
Description
Event Type
Event
Subtype
Subtype
Value
Expedites
Polling
Event Source
(IMO Name)
Activate Flow
Correlate
Is Correlation
Allowed
Weight
Auto Clear
Severity
Is Ticketable
Auto Remove
Flapping

Link down syslog

link down syslog

link down syslog

down / Down

ce-qinq-status-telnet/mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bundle-status/mpls traffic engineering tunnel information/ipinterface oper status

IIPInterface

F

T

F

0

T

maj

F

T

T

Link up syslog

link down syslog

link up syslog

up / Up

ce-qinq-status-telnet/mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bundle-status/mpls traffic engineering tunnel information/ipinterface oper status

IIPInterface

F

F

F

0

F

clr

F

T

T

Link down syslog

link down syslog

link down syslog

down / Down

ip interface oper status

IIPInterface

F

T

F

0

T

maj

F

T

T

Link up syslog

link down syslog

link up syslog

up / Up

mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mtop-cem-group-status/bundle-status/mpls traffic engineering tunnel information/ip interface oper status

IIPInterface

F

F

F

0

F

clr

F

T

T

Line down syslog

line down syslog

line down syslog

down / Down

mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mpls traffic engineering tunnel information / port-status/ip interface oper status

IPortLayer1

F

T

F

0

T

maj

F

T

T

Line up syslog

line down syslog

line up syslog

up / Up

mtop-mlpppbundle-status-telnet/mtop-ima-group-state-telnet/mpls traffic engineering tunnel information / port-status/ip interface oper status

IPortLayer1

F

F

F

0

F

clr

F

T

T

OSPF neighbor down syslog

ospf neighbor syslog

ospf neighbor down syslog

Down

N

IIPInterface

T

T

F

0

F

maj

T

T

F

OSPF neighbor up syslog

ospf neighbor syslog

ospf neighbor up syslog

Up / LOADING to FULL

N

IIPInterface

F

F

F

0

F

clr

F

T

F

envmon powersupply syslog

envmon powersupply syslog

envmon powersupply syslog

N/A

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon condition syslog

envmon condition syslog

envmon condition syslog

ENV_CONDITION

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon condition clear syslog

envmon condition syslog

envmon condition clear syslog

ENV_CONDITION_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

envmon fan syslog

envmon fan syslog

envmon fan syslog

FAN

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon fan clear syslog

envmon fan syslog

envmon fan clear syslog

FAN_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

envmon fan syslog

envmon fan syslog

envmon fan syslog

N/A

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon tempretaure syslog

envmon tempretaure syslog

envmon tempretaure syslog

OVERTEMP

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon tempretaure clear syslog

envmon tempretaure syslog

envmon tempretaure clear syslog

OVERTEMP_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

card out syslog

card out syslog

card out syslog

REMOVE

physical-command

IManagedElement

F

T

F

0

T

maj

F

T

T

card in syslog

card out syslog

card in syslog

INSERT

physical-command

IManagedElement

F

F

F

0

F

clr

F

T

T

envmon powersupply syslog

envmon powersupply syslog

envmon powersupply syslog

POWERSUPPLY_CURRENT

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon powersupply clear syslog

envmon powersupply syslog

envmon powersupply clear syslog

POWERSUPPLY_CURRENT_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

envmon powersupply syslog

envmon powersupply syslog

envmon powersupply syslog

POWERSUPPLY_NONOP

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon powersupply clear syslog

envmon powersupply syslog

envmon powersupply clear syslog

POWERSUPPLY_NONOP_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

envmon powersupply syslog

envmon powersupply syslog

envmon powersupply syslog

POWERSUPPLY_VOLTAGE

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon powersupply clear syslog

envmon powersupply syslog

envmon powersupply clear syslog

POWERSUPPLY_VOLTAGE_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

envmon tempretaure syslog

envmon tempretaure syslog

envmon tempretaure syslog

TEMP

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon tempretaure clear syslog

envmon tempretaure syslog

envmon tempretaure clear syslog

TEMP_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

envmon powersupply syslog

envmon powersupply syslog

envmon powersupply syslog

VOLTAGE

N

IManagedElement

F

T

T

0

T

maj

F

T

F

envmon powersupply clear syslog

envmon powersupply syslog

envmon powersupply clear syslog

VOLTAGE_CLEAR-

N

IManagedElement

F

F

F

0

F

clr

F

T

F

fabric hardware syslog

fabric hardware syslog

fabric hardware syslog

FIAHW_LOS

N

IManagedElement

F

T

T

0

T

maj

F

T

F

fabric hardware clear syslog

fabric hardware syslog

fabric hardware clear syslog

FIAHW_LOS_CLEAR

N

IManagedElement

F

F

F

0

F

clr

F

T

F

flash card removed syslog

flash card removed syslog

flash card removed syslog

UNAVAILABLE

N

IManagedElement

F

T

T

0

T

maj

F

T

F

flash card inserted syslog

flash card removed syslog

flash card inserted syslog

SWAPPED

N

IManagedElement

F

F

F

0

F

clr

F

T

F

Memory allocation is not available

memory allocation syslog

memory allocation syslog

N/A

N

IManagedElement

F

T

F

0

T

min

F

T

F

Module reset syslog

reset module syslog

reset module syslog

N/A

N

IManagedElement

F

T

T

0

F

info

T

T

T

Card oper status changed

card down syslog

card down syslog

UNPOWERED / DOWN / BRINGDOWN / NOT / DISABLED

card status

IModule

F

T

F

0

T

min

F

T

T

Card oper status changed

card down syslog

card up syslog

IOS XR RUN / OK

card status

IModule

F

F

F

0

F

clr

F

T

T

card out syslog

card out syslog

card out syslog

OIROUT

physical-command

IModule

F

T

F

0

T

maj

F

T

T

card in syslog

card out syslog

card in syslog

OIRIN

N

IModule

F

F

F

0

F

clr

F

T

T

card out syslog

card out syslog

card out syslog

OIROUT

physical-command

IModule

F

T

F

0

T

maj

F

T

T

card in syslog

card out syslog

card in syslog

OIRIN

N

IModule

F

F

F

0

F

clr

F

T

T

pim neighbor loss syslog

pim neighbor loss syslog

pim neighbor loss syslog

DOWN

N

IIPInterface

F

T

F

0

F

maj

F

T

F

pim neighbor up syslog

pim neighbor loss syslog

pim neighbor up syslog

UP

N

IIPInterface

F

F

F

0

F

clr

F

T

F

pim interface down syslog

pim interface down syslog

pim interface down syslog

DOWN

N

IManagedElement

F

T

F

0

T

maj

F

T

F

pim interface up syslog

pim interface down syslog

pim interface up syslog

UP

N

IManagedElement

F

F

F

0

F

clr

F

T

F

pim invalid join syslog

pim invalid join syslog

pim invalid join syslog

N/A

N

IManagedElement

F

T

F

0

T

min

F

T

F

Card oper status changed

card down syslog

card down syslog

off

N

IManagedElement

F

T

F

0

T

min

F

T

T

Card oper status changed

card down syslog

card up syslog

on

N

IManagedElement

F

F

F

0

F

clr

F

T

T

Line down syslog

line down syslog

line down syslog

N/A

N

IPortLayer1

F

T

F

0

T

maj

F

T

T

Line up syslog

line down syslog

line up syslog

cleared

N

IPortLayer1

F

F

F

0

F

clr

F

T

T

card out syslog

card out syslog

card out syslog

REMOVED

physical-command

IModule

F

T

F

0

T

maj

F

T

T

card in syslog

card out syslog

card in syslog

INSERTED

N

IModule

F

F

F

0

F

clr

F

T

T

LDP neighbor down syslog

ldp neighbor down syslog

ldp neighbor down syslog

DOWN

mpls interfaces, label switching table, mpls-ldp-peers

IProfileContainer (LSE)

F

T

F

0

T

maj

F

T

F

LDP neighbor up syslog

ldp neighbor down syslog

ldp neighbor up syslog

UP

mpls interfaces, label switching table, mpls-ldp-peers

IProfileContainer (LSE)

F

F

F

0

F

clr

F

T

F

BGP neighbor down syslog

bgp neighbor down syslog

bgp neighbor down syslog

down / Down

bgp neighbours

IBgpNeighbourEntry

F

T

F

0

T

maj

F

T

F

BGP neighbor up syslog

bgp neighbor down syslog

bgp neighbor up syslog

up / Up

bgp neighbours

IBgpNeighbourEntry

F

F

F

0

F

clr

F

T

F

Login authentication failed syslog

login authentication failed syslog

login authentication failed syslog

N/A

N

IManagedElement

F

F

F

0

F

min

T

T

F

If-Table in sync syslog

if table in sync syslog

if table in sync syslog

N/A

physical-command

IModule

F

T

F

0

F

info

F

T

F

bfd session down syslog

bfd session down syslog

bfd session down syslog

down

bfd session

IBfdService

F

T

F

0

T

maj

F

T

F

bfd session removed syslog

bfd session down syslog

bfd session removed syslog

removed

bfd session

IBfdService

F

T

F

0

T

maj

F

T

F

bfd session up syslog

bfd session down syslog

bfd session up syslog

up

bfd session

IBfdService

F

F

F

0

F

clr

F

T

F

Layer2 G709 alarm syslog

layer2 G709 alarm syslog

layer2 G709 alarm syslog

N/A

N

DWDM Oid

F

F

F

0

T

wrn

F

T

F

Layer2 G709 clear syslog

layer2 G709 alarm syslog

layer2 G709 clear syslog

cleared

N

DWDM Oid

F

F

F

0

F

clr

F

T

F

Layer2 dwdm info syslog

layer2 dwdm info syslog

layer2 dwdm info syslog

N/A

N

IManagedElement

F

F

F

0

T

min

F

T

F

Layer1 PM TCA syslog

layer1 PM TCA syslog

layer1 PM TCA syslog

N/A

N

DWDM Oid

F

F

F

0

T

wrn

F

T

F

Layer2 SPA failure syslog

layer2 SPA failure syslog

layer2 SPA failure syslog

N/A

N

IManagedElement

F

T

F

0

T

min

F

T

F

OSPF routing neighbor down syslog

ospf routing neighbor syslog

ospf routing neighbor down syslog

Down/DOWN

N

IIPInterface

T

T

F

0

F

maj

T

T

F

OSPF routing neighbor up syslog

ospf routing neighbor syslog

ospf routing neighbor up syslog

Up / LOADING to FULL

N

IIPInterface

F

F

F

0

F

clr

F

T

F

OSPFv3 neighbor down syslog

ospfv3 neighbor syslog

ospfv3 neighbor down syslog

Down / DOWN

N

IManagedElement

T

T

F

0

F

maj

T

T

F

OSPFv3 neighbor up syslog

ospfv3 neighbor syslog

ospfv3 neighbor up syslog

Up / FULL

N

IManagedElement

F

F

F

0

F

clr

F

T

F

OSPFv3 routing neighbor down syslog

ospfv3 routing neighbor down syslog

ospfv3 routing neighbor down syslog

Down / DOWN

N

IManagedElement

F

T

F

0

F

maj

T

T

F

OSPFv3 routing neighbor up syslog

ospfv3 routing neighbor down syslog

ospfv3 routing neighbor up syslog

Up / FULL

N

IManagedElement

F

F

F

0

F

clr

F

T

F

Routing BGP neighbor down syslog

routing bgp neighbor down syslog

routing bgp neighbor down syslog

down / Down

N

IBgpNeighbourEntry

F

T

F

0

F

maj

F

T

F

Routing BGP neighbor up syslog

routing bgp neighbor down syslog

routing bgp neighbor up syslog

up / Up

N

IBgpNeighbourEntry

F

F

F

0

F

clr

F

T

F

IPv6 Routing BGP neighbor down syslog

ipv6 routing bgp neighbor down syslog

ipv6 routing bgp neighbor down syslog

down / Down

N

IManagedElement

F

T

F

0

F

maj

F

T

F

IPv6 Routing BGP neighbor up syslog

ipv6 routing bgp neighbor down syslog

ipv6 routing bgp neighbor up syslog

up / Up

N

IManagedElement

F

F

F

0

F

clr

F

T

F

pseudo wire tunnel down syslog

pseudo wire tunnel syslog

pseudo wire tunnel down syslog

 

ce-pw-tunnel-status-telnet

PTPLayer2MplsTunnel

F

T

F

0

F

min

T

T

T

pseudo wire tunnel up syslog

pseudo wire tunnel syslog

pseudo wire tunnel up syslog

 

ce-pw-tunnel-status-telnet

PTPLayer2MplsTunnel

F

F

F

0

F

clr

T

T

T

EFP service error disabled syslog

efp service error disabled syslog

efp service error disabled syslog

 

EFP status

IEFP

F

T

F

0

F

info

F

T

F

DWDM feature not implemented yet

Dwdm not implemented syslog

Dwdm not implemented syslog

 

N

IManagedElement

F

F

F

0

T

wrn

false

T

F

DWDM fatal error with reason and error number

DWDM fatal error 2 syslog

DWDM fatal error 2 syslog

 

N

IManagedElement

F

F

F

0

T

maj

false

T

F

DWDM fatal error with reason

DWDM fatal error syslog

DWDM fatal error 2 syslog

 

N

IManagedElement

F

F

F

0

T

maj

false

T

F

PLIM EIO training errors syslog

PLIM EIO training errors syslog

PLIM EIO training errors syslog

 

N

IManagedElement

F

F

F

0

T

maj

false

T

F

PLIM Checkpoint Initialization Failure syslog

PLIM check point failure syslog

PLIM check point failure syslog

 

N

IManagedElement

F

F

F

0

T

min

false

T

F

PLIM ASIC error syslog

PLIM asic error syslog

PLIM asic error syslog

 

N

IManagedElement

F

F

F

0

T

min

false

T

F

PLIM memory error syslog

PLIM memory error syslog

PLIM memory error syslog

 

N

IManagedElement

F

F

F

0

T

maj

false

T

F

PLIM squid error syslog

PLIM squid error syslog

PLIM squid error syslog

 

N

IManagedElement

F

F

F

0

T

min

false

T

F

PLIM 7 error syslog

PLIm 7b error syslog

PLIm 7b error syslog

 

N

IManagedElement

F

F

F

0

T

min

false

T

F

PLIM OC768 critical error syslog

PLIM OC768 critical error syslog

PLIM OC768 critical error syslog

 

N

IManagedElement

F

F

F

0

T

maj

false

T

F

PLIM OC768 INFO syslog

PLIM OC768 INFO syslog

PLIM OC768 INFO syslog

 

N

IManagedElement

F

F

F

0

T

info

false

T

F

PLIM OC768 debug syslog

PLIM OC768 debug syslog

PLIM OC768 debug syslog

 

N

IManagedElement

F

F

F

0

T

info

false

T

F

BGP notification syslog

bgp notification syslog

bgp notification syslog

 

N

IPhysicalLayer

T

T

F

0

F

info

F

T

F

BGP notification syslog

bgp notification syslog

bgp notification syslog

 

N

IPhysicalLayer

T

T

F

0

F

info

F

T

F